dc.description.abstract | In this work, a novel ambulatory ECG monitoring device developed in-house called HOLTIN is analyzed when operating in complex indoor scenarios. The HOLTIN system is described, from the technological platform level to its functional model. In addition, by using in-house 3D ray launching simulation code, the wireless channel behavior, which enables ubiquitous operation, is performed. The effect of human body presence is taken into account by a novel simplified model embedded within the 3D Ray Launching code. Simulation as well as measurement results are presented, showing good agreement. These results may aid in the adequate deployment of this novel device to automate conventional medical processes, increasing the coverage radius and optimizing energy consumption. | en |
dc.description.sponsorship | The authors wish to thank the support given under project ENEIDA TEC2010-21563-C02-01, funded by the Ministry of Economy and Competitiveness of Spain. | en |
dc.format.mimetype | application/pdf | en |
dc.language.iso | eng | en |
dc.publisher | MDPI | en |
dc.relation.ispartof | Sensors 2013, 13(4), 4947-4960 | es |
dc.rights | © 2013 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/3.0/). | en |
dc.rights.uri | http://creativecommons.org/licenses/by/3.0/ | |
dc.subject | Ambulatory electrocardiogram | en |
dc.subject | U-Health | en |
dc.subject | HOLTIN | en |
dc.subject | 3D ray launching | en |
dc.title | Analysis and description of HOLTIN service provision for AECG monitoring in complex indoor environments | en |
dc.type | Artículo / Artikulua | es |
dc.type | info:eu-repo/semantics/article | en |
dc.contributor.department | Ingeniería Eléctrica y Electrónica | es_ES |
dc.contributor.department | Ingeniaritza Elektrikoa eta Elektronikoa | eu |
dc.rights.accessRights | Acceso abierto / Sarbide irekia | es |
dc.rights.accessRights | info:eu-repo/semantics/openAccess | en |
dc.identifier.doi | 10.3390/s130404947 | |
dc.relation.projectID | info:eu-repo/grantAgreement/MICINN//TEC2010-21563-C02-01/ES/ | en |
dc.relation.publisherversion | https://dx.doi.org/10.3390/s130404947 | |
dc.type.version | Versión publicada / Argitaratu den bertsioa | es |
dc.type.version | info:eu-repo/semantics/publishedVersion | en |