Mostrar el registro sencillo del ítem

dc.creatorMillor Muruzábal, Noraes_ES
dc.creatorLecumberri Villamediana, Pabloes_ES
dc.creatorGómez Fernández, Marisoles_ES
dc.creatorMartínez Ramírez, Aliciaes_ES
dc.creatorIzquierdo Redín, Mikeles_ES
dc.date.accessioned2015-09-28T06:38:05Z
dc.date.available2015-09-28T06:38:05Z
dc.date.issued2013
dc.identifier.issn1743-0003 (electronic)
dc.identifier.urihttps://hdl.handle.net/2454/18285
dc.description.abstractBackground: A growing interest in frailty syndrome exists because it is regarded as a major predictor of co-morbidities and mortality in older populations. Nevertheless, frailty assessment has been controversial, particularly when identifying this syndrome in a community setting. Performance tests such as the 30-second chair stand test (30-s CST) are a cornerstone for detecting early declines in functional independence. Additionally, recent advances in body-fixed sensors have enhanced the sensors’ ability to automatically and accurately evaluate kinematic parameters related to a specific movement performance. The purpose of this study is to use this new technology to obtain kinematic parameters that can identify frailty in an aged population through the performance the 30-s CST. Methods: Eighteen adults with a mean age of 54 years, as well as sixteen pre-frail and thirteen frail patients with mean ages of 78 and 85 years, respectively, performed the 30-s CST while threir trunk movements were measured by a sensor-unit at vertebra L3. Sit-stand-sit cycles were determined using both acceleration and orientation information to detect failed attempts. Movement-related phases (i.e. impulse, stand-up, and sit-down) were differentiated based on seat off and seat on events. Finally, the kinematic parameters of the impulse, stand-up and sit-down phases were obtained to identify potential differences across the three frailty groups. Results: For the stand-up and sit-down phases, velocity peaks and “modified impulse” parameters clearly differentiated subjects with different frailty levels (p < 0.001). The trunk orientation range during the impulse phase was also able to classify a subject according to his frail syndrome (p < 0.001). Furthermore, these parameters derived from the inertial units (IUs) are sensitive enough to detect frailty differences not registered by the number of completed cycles which is the standard test outcome. Conclusions: This study shows that IUs can enhance the information gained from tests currently used in clinical practice, such as the 30-s CST. Parameters such as velocity peaks, impulse, and orientation range are able to differentiate between adults and older populations with different frailty levels. This study indicates that early frailty detection could be possible in clinical environments, and the subsequent interventions to correct these disabilities could be prescribed before further degradation occurs.en
dc.description.sponsorshipThe authors are indebted to the Spanish Department of Health and Institute Carlos III of the Government of Spain [Spanish Net on Aging and frailty; (RETICEF)], Department of Health of the Government of Navarre and Economy and Competitivity Department of the Government of Spain, for financing this research with grants numbered RD12/0043/0022, 87/2010, and DEP2011-24105 respectively.en
dc.format.mimetypeapplication/pdfen
dc.language.isoengen
dc.publisherBioMed Centralen
dc.relation.ispartofJournal of NeuroEngineering and Rehabilitation 2013 10:86en
dc.rights© 2013 Millor et al.; licensee BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.en
dc.rights.urihttp://creativecommons.org/licenses/by/2.0/
dc.subjectInertial unitsen
dc.subjectFrailty syndromeen
dc.subjectKinematic parametersen
dc.subject30-s chair stand testen
dc.subjectSignal analysisen
dc.titleAn evaluation of the 30-s chair stand test in older adults: frailty detection based on kinematic parameters from a single inertial uniten
dc.typeinfo:eu-repo/semantics/articleen
dc.typeArtículo / Artikuluaes
dc.contributor.departmentMatemáticases_ES
dc.contributor.departmentCiencias de la Saludes_ES
dc.contributor.departmentMatematikaeu
dc.contributor.departmentOsasun Zientziakeu
dc.rights.accessRightsinfo:eu-repo/semantics/openAccessen
dc.rights.accessRightsAcceso abierto / Sarbide irekiaes
dc.identifier.doi10.1186/1743-0003-10-86
dc.relation.projectIDinfo:eu-repo/grantAgreement/MICINN//DEP2011-24105/ES/en
dc.relation.publisherversionhttps://dx.doi.org/10.1186/1743-0003-10-86
dc.type.versioninfo:eu-repo/semantics/publishedVersionen
dc.type.versionVersión publicada / Argitaratu den bertsioaes
dc.contributor.funderGobierno de Navarra / Nafarroako Gobernua


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

© 2013 Millor et al.; licensee BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative
Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and
reproduction in any medium, provided the original work is properly cited.
La licencia del ítem se describe como © 2013 Millor et al.; licensee BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

El Repositorio ha recibido la ayuda de la Fundación Española para la Ciencia y la Tecnología para la realización de actividades en el ámbito del fomento de la investigación científica de excelencia, en la Línea 2. Repositorios institucionales (convocatoria 2020-2021).
Logo MinisterioLogo Fecyt