Mostrar el registro sencillo del ítem

dc.creatorRodríguez Rodríguez, Adolfo Josuées_ES
dc.creatorRuiz Zamarreño, Carloses_ES
dc.creatorMatías Maestro, Ignacioes_ES
dc.creatorArregui San Martín, Francisco Javieres_ES
dc.creatorCruz, Renées_ES
dc.creatorMay Arrioja, Daniel A.es_ES
dc.date.accessioned2017-11-15T09:28:39Z
dc.date.available2017-11-15T09:28:39Z
dc.date.issued2014
dc.identifier.issn1424-8220
dc.identifier.urihttps://hdl.handle.net/2454/26157
dc.description.abstractA universal pH indicator is used to fabricate a fiber optic ammonia sensor. The advantage of this pH indicator is that it exhibits sensitivity to ammonia over a broad wavelength range. This provides a differential response, with a valley around 500 nm and a peak around 650 nm, which allows us to perform ratiometric measurements. The ratiometric measurements provide not only an enhanced signal, but can also eliminate any external disturbance due to humidity or temperature fluctuations. In addition, the indicator is embedded in a hydrophobic and gas permeable polyurethane film named Tecoflex®. The film provides additional advantages to the sensor, such as operation in dry environments, efficient transport of the element to be measured to the sensitive area of the sensor, and prevent leakage or detachment of the indicator. The combination of the universal pH indicator and Tecoflex® film provides a reliable and robust fiber optic ammonia sensor.en
dc.description.sponsorshipWe appreciate the support from the Consejo Nacional de Ciencia y Tecnología (CONACyT) under contract CB-2010/157866. This work was also supported by the Spanish Economy and Competitivity Ministry-FEDER TEC2010-17805.en
dc.format.extent14 p.
dc.format.mimetypeapplication/pdfen
dc.language.isoengen
dc.publisherMDPIen
dc.relation.ispartofSensors, 2014, 14(3), 4060-4073en
dc.rights© 2014 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license.en
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/3.0/
dc.subjectFiber optics sensoren
dc.subjectAmmonia sensoren
dc.subjectOptical sensoren
dc.titleA fiber optic ammonia sensor using a universal pH indicatoren
dc.typeArtículo / Artikuluaes
dc.typeinfo:eu-repo/semantics/articleen
dc.contributor.departmentIngeniería Eléctrica y Electrónicaes_ES
dc.contributor.departmentIngeniaritza Elektrikoa eta Elektronikoaeu
dc.rights.accessRightsAcceso abierto / Sarbide irekiaes
dc.rights.accessRightsinfo:eu-repo/semantics/openAccessen
dc.identifier.doi10.3390/s140304060
dc.relation.projectIDinfo:eu-repo/grantAgreement/MICINN//TEC2010-17805/ES/en
dc.relation.publisherversionhttps://dx.doi.org/10.3390/s140304060
dc.type.versionVersión publicada / Argitaratu den bertsioaes
dc.type.versioninfo:eu-repo/semantics/publishedVersionen


Ficheros en el ítem

Thumbnail

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

© 2014 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license.
La licencia del ítem se describe como © 2014 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license.

El Repositorio ha recibido la ayuda de la Fundación Española para la Ciencia y la Tecnología para la realización de actividades en el ámbito del fomento de la investigación científica de excelencia, en la Línea 2. Repositorios institucionales (convocatoria 2020-2021).
Logo MinisterioLogo Fecyt