El monitoreo de los diferentes signos vitales en vacunos tiene importancia desde el
punto de vista productivo, sanitario y de bienestar animal; sin embargo, existen pocos
equipos que tengan el potencial de uso a nivel de campo y que no sean invasivos. Por tal
motivo se llevó a cabo el presente trabajo con la finalidad de diseñar, construir y evaluar
el uso de un pequeño MOnitor de SIgnos VIta ...
[++]
El monitoreo de los diferentes signos vitales en vacunos tiene importancia desde el
punto de vista productivo, sanitario y de bienestar animal; sin embargo, existen pocos
equipos que tengan el potencial de uso a nivel de campo y que no sean invasivos. Por tal
motivo se llevó a cabo el presente trabajo con la finalidad de diseñar, construir y evaluar
el uso de un pequeño MOnitor de SIgnos VItales LLevable (MOSIVILLe), que sea capaz
de capturar las señales vitales en vacunos bajo condiciones de campo. El diseño y
desarrollo del MOSIVILLe se realizó en Lima, Perú, entre enero y octubre de 2017 y la
evaluación en campo se realizó en Chota, Perú, utilizando 11 vaquillas entre noviembre de
2017 y febrero de 2018. Con el uso del MOSIVILLe se obtuvieron las señales vitales de
vacunos, reconociéndose las ondas P, Q, R, S, T, complejo QRS e intervalo RR del electrocardiograma
que condujeron a obtener la frecuencia cardiaca (FC). Adicionalmente, se
obtuvo la temperatura de la piel (T°P) y la señal de ventilación con los picos de inhalación,
exhalación, tiempo de inspiración y tiempo de espiración que determinan la frecuencia
respiratoria (FR). El MOSIVILLe usado en vacunos en condiciones de campo permitió
obtener una FC de 70.83±1.47, FR de 25.24±1.64 y una T°P de 31.52±0.40 (promedio ± error
estándar), valores que se encuentran en concordancia con la literatura. Se concluye que
el MOSIVILLe es una alternativa importante para obtener diversos signos vitales en
vacunos bajo condiciones de campo. [--]
The monitoring of various vital signs in cattle is important from the point of view of production, health and animal welfare; however, there are few devices that have the potential to be used at the field level and that are not invasive. For this reason, the present work was carried out with the purpose of designing, constructing and evaluating the use of wearable vital signs monitor (MOSIVILLe), ...
[++]
The monitoring of various vital signs in cattle is important from the point of view of production, health and animal welfare; however, there are few devices that have the potential to be used at the field level and that are not invasive. For this reason, the present work was carried out with the purpose of designing, constructing and evaluating the use of wearable vital signs monitor (MOSIVILLe), which is capable of capturing the vital signs in cattle under field conditions. The design and development of MOSIVILLe was carried out in Lima, Peru, between January and October 2017 and the field evaluation was carried out in Chota, Peru, using 11 heifers between November 2017 and February 2018. The vital signs of cattle were obtained with the MOSIVILLe, recognizing the P, Q, R, S, T waves, QRS complex and RR interval of the electrocardiogram that led to obtain the heart rate (HR). Additionally, the skin temperature (T degrees S) and the ventilation signal were obtained with the peaks of inhalation, exhalation, inspiration time and expiration time that determine the respiratory frequency (RF). MOSIVILLe used in cattle in field conditions allowed to obtain an HR of 70.83 +/- 1.47, RF of 25.24 +/- 1.64 and a T degrees S of 31.52 +/- 0.40 (mean +/- standard error), values that agree with the literature. It is concluded that MOSIVILLe is an important alternative to obtain various vital signs in cattle under field conditions. [--]
Materias
Electrocardiograma,
ECG,
Respiración,
Temperatura de la piel,
Equipo llevable,
Electrocardiogram,
ECG,
Breathing,
Skin temperature,
Wearable medical device
Editor
Universidad Nacional Mayor de San Marcos (Perú)
Publicado en
Revista de Investigaciones Veterinarias del Perú, 2019; 30(1): 74-87
Departamento
Universidad Pública de Navarra. Departamento de Ingeniería Eléctrica, Electrónica y de Comunicación /
Nafarroako Unibertsitate Publikoa. Ingeniaritza Elektrikoa, Elektronikoa eta Telekomunikazio Ingeniaritza Saila /
Universidad Pública de Navarra/Nafarroako Unibertsitate Publikoa. Institute of Smart Cities - ISC