Person:
Malanda Trigueros, Armando

Loading...
Profile Picture

Email Address

Birth Date

Research Projects

Organizational Units

Job Title

Last Name

Malanda Trigueros

First Name

Armando

person.page.departamento

Ingeniería Eléctrica, Electrónica y de Comunicación

person.page.instituteName

ISC. Institute of Smart Cities

ORCID

0000-0002-3122-9049

person.page.upna

379

Name

Search Results

Now showing 1 - 10 of 19
  • PublicationOpen Access
    Métodos de procesamiento y análisis de señales electromiográficas
    (Gobierno de Navarra, 2009) Gila Useros, Luis; Malanda Trigueros, Armando; Rodríguez Carreño, Ignacio; Rodríguez Falces, Javier; Navallas Irujo, Javier; Ingeniería Eléctrica y Electrónica; Ingeniaritza Elektrikoa eta Elektronikoa
    La electromiografía clínica es una metodología de registro y análisis de la actividad bioeléctrica del músculo esquelético orientada al diagnóstico de las enfermedades neuromusculares. Las posibilidades de aplicación y el rendimiento diagnóstico de la electromiografía han evolucionado paralelamente al conocimiento de las propiedades de la energía eléctrica y al desarrollo de la tecnología eléctrica y electrónica. A mediados del siglo XX se introdujo el primer equipo comercial de electromiografía para uso médico basado en circuitos electrónicos analógicos. El desarrollo posterior de la tecnología digital ha permitido disponer de sistemas controlados por microprocesadores cada vez más fiables y potentes para captar, representar, almacenar, analizar y clasificar las señales mioeléctricas. Es esperable que el avance de las nuevas tecnologías de la información y la comunicación pueda conducir en un futuro próximo a la aplicación de desarrollos de inteligencia artificial que faciliten la clasificación automática de señales así como sistemas expertos de apoyo al diagnóstico electromiográfico.
  • PublicationOpen Access
    Motor unit action potential duration, I: variability of manual and automatic measurements
    (Lippincott, Williams & Wilkins, 2007) Rodríguez Carreño, Ignacio; Gila Useros, Luis; Malanda Trigueros, Armando; García Gurtubay, Ignacio; Mallor Giménez, Fermín; Gómez Elvira, Sagrario; Rodríguez Falces, Javier; Navallas Irujo, Javier; Ingeniería Eléctrica y Electrónica; Estadística e Investigación Operativa; Ingeniaritza Elektrikoa eta Elektronikoa; Estatistika eta Ikerketa Operatiboa
    To analyze the variability in manual measurements of motor unit action potential (MUAP) duration and to evaluate the effectiveness of well-known algorithms for automatic measurement. Two electromyographists carried out three independent duration measurements of a set of 240 MUAPs. The intraexaminer and interexaminer variabilities were analyzed by means of the Gage Reproducibility and Repeatability method. The mean of the three closest manually marked positions was considered the gold standard of the duration markers positions (GSP). The results of four wellknown automatic methods for estimating MUAP duration were compared with the GSP. Manual measurements of duration showed a lot of variability, with the combined intraoperator and interoperator variability greater than 30%. The greatest difference between manual positions was 11.2 ms. The mean differences between the GSP and those obtained with the four automatic methods ranged between 0.6 and 8.5 ms. Both manual and automatic measurements of MUAP duration show a high degree of variability. More precise methods are needed to improve the accuracy and reliability of the estimates of this parameter.
  • PublicationOpen Access
    Exact inter-discharge interval distribution of motor unit firing patterns with gamma model
    (Springer, 2019) Navallas Irujo, Javier; Porta Cuéllar, Sonia; Malanda Trigueros, Armando; Ingeniería Eléctrica, Electrónica y de Comunicación; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren
    Inter-discharge interval distribution modeling of the motor unit firing pattern plays an important role in electromyographic decomposition and the statistical analysis of firing patterns. When modeling firing patterns obtained from automatic procedures, false positives and false negatives can be taken into account to enhance performance in estimating firing pattern statistics. Available models of this type, however, are only approximate and use Gaussian distributions, which are not strictly suitable for modeling renewal point processes. In this paper, the theory of point processes is used to derive an exact solution to the distribution when a gamma distribution is used to model the physiological firing pattern. Besides being exact, the solution provides a way to model the skewness of the inter-discharge distribution, and this may make it possible to obtain a better fit with available experimental data. In order to demonstrate potential applications of the model, we use it to obtain a maximum likelihood estimator of firing pattern statistics. Our tests found this estimator to be reliable over a wide range of firing conditions, whether dealing with real or simulated firing patterns, the proposed solution had better agreement than other models.
  • PublicationOpen Access
    Sliding window averaging in normal and pathological motor unit action potential trains
    (Elsevier, 2018) Malanda Trigueros, Armando; Navallas Irujo, Javier; Rodríguez Falces, Javier; Porta Cuéllar, Sonia; Fernández Martínez, Miguel; Ingeniería Eléctrica, Electrónica y de Comunicación; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren
    Objective: To evaluate the performance of a recently proposed motor unit action potential (MUAP) averaging method based on a sliding window, and compare it with relevant published methods in normal and pathological muscles. Methods: Three versions of the method (with different window lengths) were compared to three relevant published methods in terms of signal analysis-based merit figures and MUAP waveform parameters used in the clinical practice. 218 MUAP trains recorded from normal, myopathic, subacute neurogenic and chronic neurogenic muscles were analysed. Percentage scores of the cases in which the methods obtained the best performance or a performance not significantly worse than the best were computed. Results: For signal processing figures of merit, the three versions of the new method performed better (with scores of 100, 86.6 and 66.7%) than the other three methods (66.7, 25 and 0%, respectively). In terms of MUAP waveform parameters, the new method also performed better (100, 95.8 and 91.7%) than the other methods (83.3, 37.5 and 25%). Conclusions: For the types of normal and pathological muscle studied, the sliding window approach extracted more accurate and reliable MUAP curves than other existing methods. Significance: The new method can be of service in quantitative EMG.
  • PublicationOpen Access
    EMG modeling
    (InTechOpen, 2012) Rodríguez Falces, Javier; Navallas Irujo, Javier; Malanda Trigueros, Armando; Ingeniería Eléctrica y Electrónica; Ingeniaritza Elektrikoa eta Elektronikoa
    The aim of this chapter is to describe the approaches used for modelling electromyographic (EMG) signals as well as the principles of electrical conduction within the muscle. Sections are organized into a progressive, step-by-step EMG modeling of structures of increasing complexity. First, the basis of the electrical conduction that allows for the propagation of the EMG signals within the muscle is presented. Second, the models used for describing the electrical activity generated by a single fibre described. The third section is devoted to modeling the organization of the motor unit and the generation of motor unit potentials. Based on models of the architectural organization of motor units and their activation and firing mechanisms, the last section focuses on modeling the electrical activity of a complete muscle as recorded at the surface.
  • PublicationOpen Access
    Association of intrinsic capacity with respiratory disease mortality
    (Elsevier, 2023) Ramírez Vélez, Robinson; Iriarte-Fernández, María; Santafé Rodrigo, Guzmán; Malanda Trigueros, Armando; Beard, John R.; García Hermoso, Antonio; Izquierdo Redín, Mikel; Ciencias de la Salud; Estadística, Informática y Matemáticas; Ingeniería Eléctrica, Electrónica y de Comunicación; Institute for Advanced Materials and Mathematics - INAMAT2; Osasun Zientziak; Estatistika, Informatika eta Matematika; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren
    The World Health Organization (WHO) introduced a framework for healthy aging in 2015 that emphasizes functional ability instead of absence of disease. Healthy ageing is defined as “the process of building and maintaining the functional ability that enables well-being”. This framework considers an individual’s intrinsic capacity (IC), environment, and the interaction between them to determine functional ability. In this prospective cohort study, we investigated the link between mortality and various respiratory diseases in almost half a million adults who are part of the UK Biobank. We derived an IC score using measures from 4 of the 5 domains: two for psychological capacity, two for sensory capacity, two for vitality and one for locomotor capacity. The exposure variable in the study was the number of reported factors, which was summed and categorized into IC scores of zero, one, two, three, or at least four. The outcome was respiratory disease-related mortality, which was linked to national mortality records. The follow-up period started from participants’ inclusion in the UK Biobank study (2006–2010) and ended on December 31, 2021, or the participant’s death was censored. The average follow-up was 10.6 years (IQR 10.0; 11.3). During a median follow-up period of 10.6 years, 27,251 deaths were recorded. Out of these, 7.5% (2059) were primarily attributed to respiratory disease. The results showed that a higher IC score (+4 points) was associated with a significantly increased risk of respiratory disease mortality, with HRs of 3.34 [2.64 to 4.23] for men (C-index = 0.83) and 3.87 [2.86 to 5.23] for women (C-index = 0.84), independent of major confounding factors (P < 0.001). Our study provides evidence that lower levels of the WHO’s IC construct are associated with increased risk of mortality and various adverse health outcomes. The IC construct, which is easily and inexpensively measured, holds great promise for transforming geriatric care worldwide, including in regions without established geriatric medicine.
  • PublicationOpen Access
    Modelling fibrillation potentials: analysis of time parameters in the muscle intracellular action potential
    (IEEE, 2007) Rodríguez Falces, Javier; Malanda Trigueros, Armando; Gila Useros, Luis; Rodríguez Carreño, Ignacio; Navallas Irujo, Javier; Ingeniería Eléctrica y Electrónica; Ingeniaritza Elektrikoa eta Elektronikoa
    A single fibre action potential (SFAP) can be modelled as the convolution of a biolectrical source and a filter impulse response. In the Dimitrov-Dimitrova (D-D) convolutional model, the first temporal derivative of the intracellular action potential (IAP) is used as the source, and T spl is a time parameter related to the duration of the IAP waveform. Our work is centred on the relation between Tspl and the main spike duration (MSD), defined as the time interval between the first and third phases of the SFAP. We show that Tspl essentially determines the MSD parameter. As experimental data, we used fibrillation potentials (FPs) of two different muscles to study the D-D model. We found that T spl should have a certain statistical variability in order to explain the variability in the MSD of our FPs. In addition, we present a method to estimate the T spl values corresponding to a given SFAP from its measured MSD.
  • PublicationOpen Access
    Association of intrinsic capacity with incidence and mortality of cardiovascular disease: prospective study in UK Biobank
    (Wiley, 2023) Ramírez Vélez, Robinson; Iriarte-Fernández, María; Santafé Rodrigo, Guzmán; Malanda Trigueros, Armando; Beard, John R.; García Hermoso, Antonio; Izquierdo Redín, Mikel; Ciencias de la Salud; Estadística, Informática y Matemáticas; Ingeniería Eléctrica, Electrónica y de Comunicación; Institute for Advanced Materials and Mathematics - INAMAT2; Osasun Zientziak; Estatistika, Informatika eta Matematika; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren; Universidad Pública de Navarra / Nafarroako Unibertsitate Publikoa
    Background: The World Health Organization proposed the concept of intrinsic capacity (IC; the composite of all the physical and mental capacities of the individual) as central for healthy ageing. However, little research has investigated the interaction and joint associations of IC with cardiovascular disease (CVD) incidence and CVD mortality in middle- and older-aged adults. Methods: Using data from 443 130 UK Biobank participants, we analysed seven biomarkers capturing the level of functioning of five domains of IC to calculate a total IC score (ranging from 0 [better IC] to +4 points [poor IC]). Associations between IC score and incidence of six long-term CVD conditions (hypertension, stroke/transient ischaemic attack stroke, peripheral vascular disease, atrial fibrillation/flutter, coronary artery disease and heart failure), and grouped mortality from these conditions were estimated using Cox proportional models, with a 1-year landmark analysis to triangulate the findings. Results: Over 10.6 years of follow-up, CVD morbidity grouped (n = 384 380 participants for the final analytic sample) was associated with IC scores (0 to +4): mean hazard ratio (HR) [95% confidence interval, CI] 1.11 [1.08–1.14], 1.20 [1.16–1.24], 1.29 [1.23–1.36] and 1.56 [1.45–1.59] in men (C-index = 0.68), and 1.17 [1.13–1.20], 1.30 [1.26–1.36], 1.52 [1.45–1.59] and 1.78 [1.67–1.89] in women (C-index = 0.70). In regard to mortality, our results indicated that the higher IC score (+4 points) was associated with a significant increase in subsequent CVD mortality (mean HR [95% CI]: 2.10 [1.81–2.43] in men [C-index = 0.75] and 2.29 [1.85–2.84] in women [C-index = 0.78]). Results of all sensitivity analyses by full sample, sex and age categories were largely consistent independent of major confounding factors (P < 0.001). Conclusions: IC deficit score is a powerful predictor of functional trajectories and vulnerabilities of the individual in relation to CVD incidence and premature death. Monitoring an individual's IC score may provide an early-warning system to initiate preventive efforts.
  • PublicationOpen Access
    A masked least-squares smoothing procedure for artifact reduction in scanning-EMG recordings
    (Springer, 2018) Corera Orzanco, Íñigo; Eciolaza Ferrando, Adrián; Rubio Zamora, Oliver; Malanda Trigueros, Armando; Rodríguez Falces, Javier; Navallas Irujo, Javier; Ingeniería Eléctrica, Electrónica y de Comunicación; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren
    Scanning-EMG is an electrophysiological technique in which the electrical activity of the motor unit is recorded at multiple points along a corridor crossing the motor unit territory. Correct analysis of the scanning-EMG signal requires prior elimination of interference from nearby motor units. Although the traditional processing based on the median filtering is effective in removing such interference, it distorts the physiological waveform of the scanning-EMG signal. In this study, we describe a new scanning-EMG signal processing algorithm that preserves the physiological signal waveform while effectively removing interference from other motor units. To obtain a cleaned-up version of the scanning signal, the masked least-squares smoothing (MLSS) algorithm recalculates and replaces each sample value of the signal using a least-squares smoothing in the spatial dimension, taking into account the information of only those samples that are not contaminated with activity of other motor units. The performance of the new algorithm with simulated scanning-EMG signals is studied and compared with the performance of the median algorithm and tested with real scanning signals. Results show that the MLSS algorithm distorts the waveform of the scanning-EMG signal much less than the median algorithm (approximately 3.5 dB gain), being at the same time very effective at removing interference components.
  • PublicationOpen Access
    EMG probability density function: a new way to look at EMG signal filling from single motor unit potential to full interference pattern
    (IEEE, 2023) Navallas Irujo, Javier; Eciolaza Ferrando, Adrián; Mariscal Aguilar, Cristina; Malanda Trigueros, Armando; Rodríguez Falces, Javier; Ingeniería Eléctrica, Electrónica y de Comunicación; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren
    An analytical derivation of the EMG signal's amplitude probability density function (EMG PDF) is presented and used to study how an EMG signal builds-up, or fills, as the degree of muscle contraction increases. The EMG PDF is found to change from a semi-degenerate distribution to a Laplacian-like distribution and finally to a Gaussian-like distribution. We present a measure, the EMG filling factor, to quantify the degree to which an EMG signal has been built-up. This factor is calculated from the ratio of two non-central moments of the rectified EMG signal. The curve of the EMG filling factor as a function of the mean rectified amplitude shows a progressive and mostly linear increase during early recruitment, and saturation is observed when the EMG signal distribution becomes approximately Gaussian. Having presented the analytical tools used to derive the EMG PDF, we demonstrate the usefulness of the EMG filling factor and curve in studies with both simulated signals and real signals obtained from the tibialis anterior muscle of 10 subjects. Both simulated and real EMG filling curves start within the 0.2 to 0.35 range and rapidly rise towards 0.5 (Laplacian) before stabilizing at around 0.637 (Gaussian). Filling curves for the real signals consistently followed this pattern (100% repeatability within trials in 100% of the subjects). The theory of EMG signal filling derived in this work provides (a) an analytically consistent derivation of the EMG PDF as a function of motor unit potentials and motor unit firing patterns; (b) an explanation of the change in the EMG PDF according to degree of muscle contraction; and (c) a way (the EMG filling factor) to quantify the degree to which an EMG signal has been built-up.