Serrano Arriezu, Luis Javier
Loading...
Email Address
person.page.identifierURI
Birth Date
Job Title
Last Name
Serrano Arriezu
First Name
Luis Javier
person.page.departamento
Ingeniería Eléctrica, Electrónica y de Comunicación
person.page.instituteName
ISC. Institute of Smart Cities
ORCID
person.page.observainves
person.page.upna
Name
- Publications
- item.page.relationships.isAdvisorOfPublication
- item.page.relationships.isAdvisorTFEOfPublication
- item.page.relationships.isAuthorMDOfPublication
17 results
Search Results
Now showing 1 - 10 of 17
Publication Open Access Implementation of context aware e-health environments based on social sensor networks(MDPI, 2016) Aguirre Gallego, Erik; Led Ramos, Santiago; López Iturri, Peio; Azpilicueta Fernández de las Heras, Leyre; Serrano Arriezu, Luis Javier; Falcone Lanas, Francisco; Ingeniería Eléctrica y Electrónica; Ingeniaritza Elektrikoa eta Elektronikoa; Gobierno de Navarra / Nafarroako GobernuaIn this work, context aware scenarios applied to e-Health and m-Health in the framework of typical households (urban and rural) by means of deploying Social Sensors will be described. Interaction with end-users and social/medical staff is achieved using a multi-signal input/output device, capable of sensing and transmitting environmental, biomedical or activity signals and information with the aid of a combined Bluetooth and Mobile system platform. The devices, which play the role of Social Sensors, are implemented and tested in order to guarantee adequate service levels in terms of multiple signal processing tasks as well as robustness in relation with the use wireless transceivers and channel variability. Initial tests within a Living Lab environment have been performed in order to validate overall system operation. The results obtained show good acceptance of the proposed system both by end users as well as by medical and social staff, increasing interaction, reducing overall response time and social inclusion levels, with a compact and moderate cost solution that can readily be largely deployed.Publication Open Access Analysis and description of HOLTIN service provision for AECG monitoring in complex indoor environments(MDPI, 2013) Led Ramos, Santiago; Azpilicueta Fernández de las Heras, Leyre; Aguirre Gallego, Erik; Martínez de Espronceda Cámara, Miguel; Serrano Arriezu, Luis Javier; Falcone Lanas, Francisco; Ingeniería Eléctrica y Electrónica; Ingeniaritza Elektrikoa eta ElektronikoaIn this work, a novel ambulatory ECG monitoring device developed in-house called HOLTIN is analyzed when operating in complex indoor scenarios. The HOLTIN system is described, from the technological platform level to its functional model. In addition, by using in-house 3D ray launching simulation code, the wireless channel behavior, which enables ubiquitous operation, is performed. The effect of human body presence is taken into account by a novel simplified model embedded within the 3D Ray Launching code. Simulation as well as measurement results are presented, showing good agreement. These results may aid in the adequate deployment of this novel device to automate conventional medical processes, increasing the coverage radius and optimizing energy consumption.Publication Open Access Implementation and operational analysis of an interactive intensive care unit within a smart health context(MDPI, 2018) López Iturri, Peio; Aguirre Gallego, Erik; Trigo Vilaseca, Jesús Daniel; Astrain Escola, José Javier; Azpilicueta Fernández de las Heras, Leyre; Serrano Arriezu, Luis Javier; Villadangos Alonso, Jesús; Falcone Lanas, Francisco; Ingeniaritza Elektrikoa eta Elektronikoa; Matematika eta Informatika Ingeniaritza; Institute of Smart Cities - ISC; Ingeniería Eléctrica y Electrónica; Ingeniería Matemática e InformáticaIn the context of hospital management and operation, Intensive Care Units (ICU) are one of the most challenging in terms of time responsiveness and criticality, in which adequate resource management and signal processing play a key role in overall system performance. In this work, a context aware Intensive Care Unit is implemented and analyzed to provide scalable signal acquisition capabilities, as well as to provide tracking and access control. Wireless channel analysis is performed by means of hybrid optimized 3D Ray Launching deterministic simulation to assess potential interference impact as well as to provide required coverage/capacity thresholds for employed transceivers. Wireless system operation within the ICU scenario, considering conventional transceiver operation, is feasible in terms of quality of service for the complete scenario. Extensive measurements of overall interference levels have also been carried out, enabling subsequent adequate coverage/capacity estimations, for a set of Zigbee based nodes. Real system operation has been tested, with ad-hoc designed Zigbee wireless motes, employing lightweight communication protocols to minimize energy and bandwidth usage. An ICU information gathering application and software architecture for Visitor Access Control has been implemented, providing monitoring of the Boxes external doors and the identification of visitors via a RFID system. The results enable a solution to provide ICU access control and tracking capabilities previously not exploited, providing a step forward in the implementation of a Smart Health framework.Publication Open Access Smart cities, IoT y salud: retos de Internet of medical things (IoMT)(Sociedad Española de Informática de la Salud, 2018) Trigo Vilaseca, Jesús Daniel; Serrano Arriezu, Luis Javier; Astrain Escola, José Javier; Falcone Lanas, Francisco; Institute of Smart Cities - ISCLa innovación tecnológica aplicada al ámbito de la salud está permitiendo el rápido desarrollo de la internet de los dispositivos médicos, o en su versión inglesa más aceptada internet of medical things (iomt). En este artículo se pretende dar una visión general de las posibilidades y retos de estas tecnologías, la cuales deben imbricarse como pilar fundamental en el desarrollo de estrategias locales, regionales y estatales de las ciudades inteligentes o smart cities.Publication Open Access Future wireless communication systems to enable IoMT services and applications(CRC Press, 2023) Trigo Vilaseca, Jesús Daniel; Astrain Escola, José Javier; Serrano Arriezu, Luis Javier; Falcone Lanas, Francisco; Ingeniería Eléctrica, Electrónica y de Comunicación; Ingeniaritza Elektrikoa, Elektronikoa eta Telekomunikazio Ingeniaritza; Estadística, Informática y Matemáticas; Estatistika, Informatika eta MatematikaWireless communication systems play a key role in the adoption of IoMT services and applications, owing to inherent mobility capabilities, providing highly scalable and flexible deployments. In this chapter, the framework for IoMT wireless communication system evolution, from current LPWAN/5G connectivity to future B5G systems, focusing on sub THz (mainly in the 100 GHz to 300 GHz frequency range) and THz bands (up to 10 THz) is described. Further, the requirements in terms of device integration, node density, interference and energy handling is also discussed. The specific requirements in terms of wearable devices, considering intra-body, on-body and off-body communication links, coverage/capacity estimations for different case uses considering different communication link types are also presented. At last, different application scenarios, such as the evolution of current IoMT applications towards sensing networks, and security as well as interoperability and standardization aspects within the IoMT communication framework are discussed in detail.Publication Open Access Analysis of bluetooth-based wireless sensor networks performance in hospital environments(MDPI, 2016) López Iturri, Peio; Led Ramos, Santiago; Aguirre Gallego, Erik; Azpilicueta Fernández de las Heras, Leyre; Serrano Arriezu, Luis Javier; Falcone Lanas, Francisco; Ingeniería Eléctrica y Electrónica; Ingeniaritza Elektrikoa eta ElektronikoaIn this work, a method to analyze the performance of Bluetooth-based Wireless Sensor Networks (WSN) deployed within hospital environments is presented. Due to the complexity that this kind of scenarios exhibit in terms of radio propagation and coexistence with other wireless communication systems and other potential interference sources, the deployment of WSNs becomes a complex task which requires an in-depth radio planning analysis. For that purpose, simulation results obtained with the aid of an in-house developed 3D Ray Launching code are presented. The scenarios under analysis are located at the Hospital of Navarre Complex (HNC), in the city of Pamplona. As hospitals have a wide variety of scenarios, the analysis has been carried out in different zones such as Boxes, where different medical sensors based on Bluetooth communication protocol have been deployed. The simulation results obtained have been validated with measurements within the scenario under analysis, exhibiting Bluetooth-based WSNs performance within hospital environments in terms of coverage/capacity relations. The proposed methodology can aid in obtaining optimal network configuration and hence performance of Bluetooth-based WSNs within medical/health service provision environments.Publication Open Access Development and validation of an automatic and intelligent system for medullation and average diameter evaluation to alpaca, llama and mohair fibers(2021) Quispe Bonilla, Max David; Quispe Peña, Edgar; Serrano Arriezu, Luis Javier; Trigo Vilaseca, Jesús Daniel; Quispe Bonilla, Christian; Institute of Smart Cities - ISCThe aim of this work was to develop and validate an automatic and intelligent system (based in artificial intelligence) capable of quantify and identify fibers, by type of medullation in 5 categories. This work was carried out in Lima, Peru. To develop the software a trained model was generated based on You Only Look at Once for medullation and DenseNet for average fiber diameter (AFD), using Python. Language C was used to develop the graphical user interface. For the hardware; mechanical, electronic and optical subsystems was design and development. Samples of white alpaca, llama and mohair fibers (2108, 1858, 901 fibers, respectively) were evaluated for identification the fibers medullation. Additionally, AFD of 197 samples of white alpacas were measured with two methods. This system identifies 5 types of medullation and measures the diameter of the fibers. Each sample is evaluated in 40 sec, considering about 1500 fibers/sample. At two-proportion z-test of different fiber medullation types obtained with direct counting and our system no significant differences were found. At t-test of AFD obtained with OFDA device and our system no significant difference were found. The relationship between these methods was very stronger (r=0.95). The use of this system is recommended for fiber evaluation for the purpose of genetic improvement of fibers in animal production; purchase-sale, and processing of fiber to verify the quality of fibers; and research on medullation to increase knowledge about alpaca, llama and mohair fibers.Publication Open Access Patient tracking in a multi-building, tunnel-connected hospital complex(IEEE, 2020) Trigo Vilaseca, Jesús Daniel; Klaina, Hicham; Picallo Guembe, Imanol; López Iturri, Peio; Astrain Escola, José Javier; Falcone Lanas, Francisco; Serrano Arriezu, Luis Javier; Ingeniería Eléctrica, Electrónica y de Comunicación; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren; Universidad Pública de Navarra / Nafarroako Unibertsitate Publikoa, PJUPNA29Patients admitted to Intensive Care Units (ICU) are transported from and to other units. Knowing their location is strategic for a sound planning of intra-hospital transports as well as resources management. This is even more crucial in big hospital complexes, comprised of several buildings often connected through tunnels. In this work, a patient tracking application in a multi-building, tunnel-connected hospital complex (the Hospital Complex of Navarre) is presented. The system leverages Internet of Medical Things (IoMT) communication technologies, such as Long Range Wide-Area Network (LoRaWAN) and Near Field Communication (NFC). The locations of the LoRaWAN nodes were selected based on several factors, including the situation of the tunnels, buildings services and medical equipment and a literature review on intra-hospital ICU patients' trips. The possible locations of the LoRaWAN gateways were selected based on 3D Ray Launching Simulations, in order to obtain accurate characterization. Once the locations were set, a LoRaWAN radio coverage studio was performed. The main conclusion drawn is that just one LoRaWAN gateway would be enough to cover all overground LoRaWAN nodes deployed. A second one would be required for underground coverage. In addition, a remote, private cloud infrastructure together with a mobile application was created to manage the information generated. On-field tests were performed to assess the technical feasibility of the system. The application provides with on-demand ICU patients' movement flow around the complex. Although designed for the ICU-admitted patients' context, the system could be easily extrapolated to other use cases.Publication Open Access Building standardized and secure mobile health services based on social media(MDPI, 2020) Trigo Vilaseca, Jesús Daniel; Rubio, Óscar J.; Martínez de Espronceda Cámara, Miguel; Alesanco, Álvaro; Alenza García, José Francisco; Serrano Arriezu, Luis Javier; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren; Institute of Smart Cities - ISC; Ingeniería Eléctrica, Electrónica y de Comunicación; Universidad Pública de Navarra / Nafarroako Unibertsitate Publikoa, PJUPNA29Mobile devices and social media have been used to create empowering healthcare services. However, privacy and security concerns remain. Furthermore, the integration of interoperability biomedical standards is a strategic feature. Thus, the objective of this paper is to build enhanced healthcare services by merging all these components. Methodologically, the current mobile health telemonitoring architectures and their limitations are described, leading to the identification of new potentialities for a novel architecture. As a result, a standardized, secure/private, social-media-based mobile health architecture has been proposed and discussed. Additionally, a technical proof-of-concept (two Android applications) has been developed by selecting a social media (Twitter), a security envelope (open Pretty Good Privacy (openPGP)), a standard (Health Level 7 (HL7)) and an information-embedding algorithm (modifying the transparency channel, with two versions). The tests performed included a small-scale and a boundary scenario. For the former, two sizes of images were tested; for the latter, the two versions of the embedding algorithm were tested. The results show that the system is fast enough (less than 1 s) for most mHealth telemonitoring services. The architecture provides users with friendly (images shared via social media), straightforward (fast and inexpensive), secure/private and interoperable mHealth services.Publication Open Access Multimodal minimally invasive wearable technology for epilepsy monitoring: a feasibility study of the periauricular area(IEEE, 2023) Besné, Guillermo M.; López Iturri, Peio; Alegre, Manuel; Artieda, Julio; Trigo Vilaseca, Jesús Daniel; Serrano Arriezu, Luis Javier; Falcone Lanas, Francisco; Valencia Ustárroz, Miguel; Institute of Smart Cities - ISCAmbulatory monitoring is of great interest in both clinical and domestic environments. Despite the technological advances, few monitoring solutions are suitable for medical application and diagnosis. Here, we investigate the feasibility of targeting the periauricular area (ear pavilion, ear canal, and the surrounding skin areas) to implement a multimodal system that fulfills the requirements of ergonomics and minimal obstructiveness in the context of epilepsy monitoring. Six physiological signals are selected and explored for their integration in the area of interest and a ¿proof-of-concept¿ prototype integrating the components in a single portable device targeting the selected location is implemented. Results show mixed results where some parameters are highly reliable, and others are impractical or require customized technology to provide clinically relevant information. To enable data acquisition, storage, and processing within the Internet of Medical Things paradigms, wireless body area transceiver integration is also analyzed in terms of coverage/capacity relations, showing feasibility for such device configuration.