López-Amo Sáinz, Manuel

Loading...
Profile Picture

Email Address

Birth Date

Job Title

Last Name

López-Amo Sáinz

First Name

Manuel

person.page.departamento

Ingeniería Eléctrica, Electrónica y de Comunicación

person.page.instituteName

ISC. Institute of Smart Cities

person.page.observainves

person.page.upna

Name

Search Results

Now showing 1 - 3 of 3
  • PublicationOpen Access
    Interferometric vs wavelength selective optical fiber sensors for cryogenic temperature measurements
    (SPIE, 2017) Miguel Soto, Verónica de; Leandro González, Daniel; López Aldaba, Aitor; Beato López, Juan Jesús; Pérez de Landazábal Berganzo, José Ignacio; Auguste, Jean-Louis; Jamier, Raphael; Roy, Philippe; López-Amo Sáinz, Manuel; Ingeniaritza Elektrikoa eta Elektronikoa; Fisika; Institute for Advanced Materials and Mathematics - INAMAT2; Ingeniería Eléctrica y Electrónica; Física
    In this work, a preliminary study of the behavior of two different interferometric fiber optic sensors and two different wavelength selective fiber optic sensors is performed. A photonic cristal fiber Fabry-Pérot interferometer, a Sagnac interferometer, a commercial fiber Bragg grating (FBG) and a π-phase shifted fiber Bragg grating interrogated in a random distributed feedback fiber laser are analyzed. A comparison of their sensitivities and resolutions is carried out to analyze their performance as sensors for cryogenic temperatures, taking into account their advantages and drawbacks.
  • PublicationOpen Access
    Study of optical fiber sensors for cryogenic temperature measurements
    (MDPI, 2017) Miguel Soto, Verónica de; Leandro González, Daniel; López Aldaba, Aitor; Beato López, Juan Jesús; Pérez de Landazábal Berganzo, José Ignacio; Auguste, Jean-Louis; Jamier, Raphael; Roy, Philippe; López-Amo Sáinz, Manuel; Ingeniaritza Elektrikoa eta Elektronikoa; Fisika; Institute for Advanced Materials and Mathematics - INAMAT2; Institute of Smart Cities - ISC; Ingeniería Eléctrica y Electrónica; Física; Universidad Pública de Navarra / Nafarroako Unibertsitate Publikoa
    In this work, the performance of five different fiber optic sensors at cryogenic temperatures has been analyzed. A photonic crystal fiber Fabry-Pérot interferometer, two Sagnac interferometers, a commercial fiber Bragg grating (FBG), and a -phase shifted fiber Bragg grating interrogated in In this work, the performance of five different fiber optic sensors at cryogenic temperatures has been analyzed. A photonic crystal fiber Fabry-Pérot interferometer, two Sagnac interferometers, a commercial fiber Bragg grating (FBG), and a π-phase shifted fiber Bragg grating interrogated in a random distributed feedback fiber laser have been studied. Their sensitivities and resolutions as sensors for cryogenic temperatures have been compared regarding their advantages and disadvantages. Additionally, the results have been compared with the given by a commercial optical backscatter reflectometer that allowed for distributed temperature measurements of a single mode fiber.
  • PublicationOpen Access
    Micro-drilled optical fiber for enhanced laser strain sensors
    (SPIE, 2019) Pérez Herrera, Rosa Ana; Bravo Acha, Mikel; Roldán Varona, Pablo; Leandro González, Daniel; Rodríguez Cobo, Luis; López Higuera, José Miguel; López-Amo Sáinz, Manuel; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren; Institute of Smart Cities - ISC; Ingeniería Eléctrica, Electrónica y de Comunicación
    In this work, we present an experimental measurement of temperature and strain sensitivities of a micro-drilled optical fiber (MDOF). The MDOF consisted of a quasi-randomly distributed reflector along a single mode fiber (SMF). A fiber cavity laser based on MDOF was experimentally studied, attaining a single-wavelength laser emission centered at 1568.6nm. The output power level obtained from this single-laser oscillation when pumped at 140mW was around - 9.6dBm, and an optical signal to noise ratio (OSNR) of around 45dB was measured. Although temperature sensitivities of fiber Bragg gratings used as sensors are similar to our MDOF, strain sensitivity is enhanced around one order of magnitude when the MDOF was used.