Bohórquez Navarro, Dina Luz

Loading...
Profile Picture

Email Address

Birth Date

Job Title

Last Name

Bohórquez Navarro

First Name

Dina Luz

person.page.departamento

Ingeniería

person.page.instituteName

person.page.observainves

person.page.upna

Name

Search Results

Now showing 1 - 2 of 2
  • PublicationOpen Access
    Generation of lossy mode resonances in a broadband range with multilayer coated coverslips optimized for humidity sensing
    (Elsevier, 2020) Bohórquez Navarro, Dina Luz; Del Villar, Ignacio; Corres Sanz, Jesús María; Matías Maestro, Ignacio; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren; Institute of Smart Cities - ISC; Ingeniería Eléctrica, Electrónica y de Comunicación; Universidad Pública de Navarra / Nafarroako Unibertsitate Publikoa
    Coverslips deposited with a metallic oxide can be employed for generating lossy mode resonances by lateral incidence of light on the coverslip. Here it is demonstrated that with copper oxide the fading observed with other materials in the near infrared (NIR) wavelength range is avoided and LMRs can be obtained in a broadband range from 400 to 1700 nm, which permitted to observe the better performance in the NIR region compared to the visible region: the sensitivity to humidity is improved by more than a factor of two. However, copper oxide is not adequate for sensing humidity. The sensitivity of the device was optimized initially with a tin oxide coating and later with an additional layer of agarose, specifically adequate for the detection of humidity. The best performance was obtained with an agarose concentration 1% w/v, which permitted to observe a 10-fold sensitivity increase compared to the same device without agarose. This opens the path towards the development of environmental, chemical or biological sensors with an optimized sensitivity to a specific parameter to detect.
  • PublicationOpen Access
    Wavelength and intensity based lossy mode resonance breathing sensor
    (Elsevier, 2021) Bohórquez Navarro, Dina Luz; Del Villar, Ignacio; Corres Sanz, Jesús María; Matías Maestro, Ignacio; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren; Institute of Smart Cities - ISC; Ingeniería Eléctrica, Electrónica y de Comunicación; Universidad Pública de Navarra / Nafarroako Unibertsitate Publikoa
    Copper oxide (CuO) allows the generation of lossy mode resonance (LMR) in a wide wavelength range of the optical spectrum, both in the visible and the near-infrared (NIR). For this, it is necessary to use a configuration based on the lateral incidence of light on the edge of a planar waveguide structure. On the other hand, the use of additional coatings of tin oxide (SnO2) and agarose allows an increase in the sensitivity of the sensor, in response to the breathing monitoring. The sensors were characterized, both in intensity and wavelength. In both cases their behavior depends on the position of the LMR in the optical spectrum. Therefore, it is convenient to extract the design rules that allow an optimal behavior of the sensor. In this sense, sensors located in the NIR presented a better behavior in terms of sensitivity and quality of the signal. In addition, the devices were tested in different conditions: repetitive tests at different distances, oral and nasal breathing, and breathing after doing physical exercise.