Otim, Timothy

Loading...
Profile Picture

Email Address

Birth Date

Job Title

Last Name

Otim

First Name

Timothy

person.page.departamento

Estadística, Informática y Matemáticas

person.page.instituteName

ORCID

person.page.observainves

person.page.upna

Name

Search Results

Now showing 1 - 2 of 2
  • PublicationOpen Access
    Effects of the body wearable sensor position on the UWB localization accuracy
    (MDPI, 2019) Otim, Timothy; Díez, Luis E.; Bahillo, Alfonso; López Iturri, Peio; Falcone Lanas, Francisco; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren; Institute of Smart Cities - ISC; Ingeniería Eléctrica, Electrónica y de Comunicación
    Over the years, several Ultrawideband (UWB) localization systems have been proposed and evaluated for accurate estimation of the position for pedestrians. However, most of them are evaluated for a particular wearable sensor position; hence, the accuracy obtained is subject to a given wearable sensor position. This paper is focused on studying the effects of body wearable sensor positions i.e., chest, arm, ankle, wrist, thigh, forehead, and hand, on the localization accuracy. According to our results, the forehead and the chest provide the best and worst body sensor location for tracking a pedestrian, respectively. With the wearable sensor at the forehead and chest position, errors lower than 0.35 m (90th percentile) and 4 m can be obtained, respectively. The reason for such a contrast in the performance lies in the fact that, in non-line-of-sight (NLOS) situations, the chest generates the highest multipath of any part of the human body. Thus, the large errors obtained arise due to the signal arriving at the target wearable sensor by multiple reflections from interacting objects in the environment rather than by direct line-of-sight (LOS) or creeping wave propagation mechanism.
  • PublicationOpen Access
    Towards sub-meter level UWB indoor localization using body wearable sensors
    (IEEE, 2020) Otim, Timothy; Bahillo, Alfonso; Enrique Díez, Luis; López Iturri, Peio; Falcone Lanas, Francisco; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren; Institute of Smart Cities - ISC; Ingeniería Eléctrica, Electrónica y de Comunicación
    Thanks to its ability to provide sub-meter level positioning accuracy, Ultrawideband (UWB) has found wide use in several wireless body area network (WBAN) applications such as ambient assisted living, remote patient management and preventive care, among others. In spite of the attractiveness of UWB, it is not possible to achieve this level of accuracy when the human body obstructs the wireless channel, leading to a bias in the Time of Flight (TOF) measurements, and hence a detection of position errors of several meters. In this paper, a study of how a sub-meter level of accuracy can be achieved after compensating for body shadowing is presented. Using a Particle Filter (PF), we apply UWB ranging error models that take into consideration the body shadowing effect and evaluate them through simulations and extensive measurements. The results show a significant reduction in the median position error of up to 75 % and 82 % for simulations and experiments, respectively, leading to the achievement of a sub-meter level of localization accuracy.