Gómez Polo, Cristina
Loading...
Email Address
person.page.identifierURI
Birth Date
Job Title
Last Name
Gómez Polo
First Name
Cristina
person.page.departamento
Ciencias
person.page.instituteName
InaMat2. Instituto de Investigación en Materiales Avanzados y Matemáticas
ORCID
person.page.observainves
person.page.upna
Name
- Publications
- item.page.relationships.isAdvisorOfPublication
- item.page.relationships.isAdvisorTFEOfPublication
- item.page.relationships.isAuthorMDOfPublication
2 results
Search Results
Now showing 1 - 2 of 2
Publication Open Access Monitoring structural transformations in metamagnetic shape memory alloys by non-contact GMI technology(IOP Publishing, 2023) Beato López, Juan Jesús; La Roca, Paulo Matías; Algueta-Miguel, Jose M.; Garayo Urabayen, Eneko; Sánchez-Alarcos Gómez, Vicente; Recarte Callado, Vicente; Gómez Polo, Cristina; Pérez de Landazábal Berganzo, José Ignacio; Ciencias; Ingeniería Eléctrica, Electrónica y de Comunicación; Institute for Advanced Materials and Mathematics - INAMAT2; Institute of Smart Cities - ISC; Zientziak; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio IngeniaritzarenDifferent applications based on metamagnetic shape memory alloy (MSMA) require monitoring the evolution of the martensitic transformation (MT) to optimize the actuation mechanism. To avoid interaction with the active material, a non-contact technique would be ideal. Nevertheless, non-contact detection involves complex methods like diffraction, optical analysis, or electromagnetic technology. The present work demonstrates that the MT can be monitored without interaction with the active material using a low-cost technology based on the Giant Magnetoimpedance (GMI) effect. The GMI sensor is based on a (CoFe)SiB soft magnetic wire submitted to an alternating current and whose second harmonic voltage variation allows to detect changes in the strength of the stray magnetic fields linked to the metamagnetic phase transition. The sensor has been tested using the MT of a NiMnInCo MSMA. A specific application for environmental temperature control using the non-contact GMI sensor is proposed.Publication Open Access Contactless magnetic nanoparticle detection platform based on non-linear GMI effect(Elsevier, 2021) Beato López, Juan Jesús; Algueta-Miguel, Jose M.; Gómez Polo, Cristina; Zientziak; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren; Institute for Advanced Materials and Mathematics - INAMAT2; Institute of Smart Cities - ISC; Ciencias; Ingeniería Eléctrica, Electrónica y de ComunicaciónA detection platform based on non-linear Giant Magnetoimpedance Effect was analyzed for the design of a contactless and low-cost detector of magnetic nanoparticles. The sensor consists of two soft magnetic amorphous wires (Co66Fe2Si13B15Cr4, 1.5 cm in length) placed in parallel and connected electrically in series. Initially, a simple voltage divider was employed to characterize the variations of the first, V1fand second harmonic, V2f, voltages. Their response was analyzed under the effect of the remnant magnetic field generated by different amounts of Fe3O4 nanoparticles (mean diameter 140 nm) as a function of an external magnetic field, H. Due to the larger relative variations showed by V2f, the second harmonic was chosen for the final prototype development. An electronic interface was designed for both current excitation and V2f detection. The designed detection platform, characterized by high detection sensitivity, low-cost, portable, and reusable features, can be employed to efficiently detect magnetic nanoparticles.