Person:
Rodríguez Falces, Javier

Loading...
Profile Picture

Email Address

Birth Date

Research Projects

Organizational Units

Job Title

Last Name

Rodríguez Falces

First Name

Javier

person.page.departamento

Ingeniería Eléctrica, Electrónica y de Comunicación

person.page.instituteName

ISC. Institute of Smart Cities

ORCID

0000-0002-9150-8955

person.page.upna

8624

Name

Search Results

Now showing 1 - 8 of 8
  • PublicationOpen Access
    Validation of the filling factor index to study the filling process of the sEMG signal in the quadriceps
    (Elsevier, 2023) Rodríguez Falces, Javier; Malanda Trigueros, Armando; Mariscal Aguilar, Cristina; Niazi, Imran Khan; Navallas Irujo, Javier; Ingeniería Eléctrica, Electrónica y de Comunicación; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren
    Introduction: The EMG filling factor is an index to quantify the degree to which an EMG signal has been filled. Here, we tested the validity of such index to analyse the EMG filling process as contraction force was slowly increased. Methods: Surface EMG signals were recorded from the quadriceps muscles of healthy subjects as force was gradually increased from 0 to 40% MVC. The sEMG filling process was analyzed by measuring the EMG filling factor (calculated from the non-central moments of the rectified sEMG). Results: (1) As force was gradually increased, one or two prominent abrupt jumps in sEMG amplitude appeared between 0 and 10% of MVC force in all the vastus lateralis and medialis. (2) The jumps in amplitude were originated when a few large-amplitude MUPs, clearly standing out from previous activity, appeared in the sEMG signal. (3) Every time an abrupt jump in sEMG amplitude occurred, a new stage of sEMG filling was initiated. (4) The sEMG was almost completely filled at 2–12% MVC. (5) The filling factor decreased significantly upon the occurrence of an sEMG amplitude jump, and increased as additional MUPs were added to the sEMG signal. (6) The filling factor curve was highly repeatable across repetitions. Conclusions: It has been validated that the filling factor is a useful, reliable tool to analyse the sEMG filling process. As force was gradually increased in the vastus muscles, the sEMG filling process occurred in one or two stages due to the presence of abrupt jumps in sEMG amplitude.
  • PublicationOpen Access
    EMG probability density function: a new way to look at EMG signal filling from single motor unit potential to full interference pattern
    (IEEE, 2023) Navallas Irujo, Javier; Eciolaza Ferrando, Adrián; Mariscal Aguilar, Cristina; Malanda Trigueros, Armando; Rodríguez Falces, Javier; Ingeniería Eléctrica, Electrónica y de Comunicación; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren
    An analytical derivation of the EMG signal's amplitude probability density function (EMG PDF) is presented and used to study how an EMG signal builds-up, or fills, as the degree of muscle contraction increases. The EMG PDF is found to change from a semi-degenerate distribution to a Laplacian-like distribution and finally to a Gaussian-like distribution. We present a measure, the EMG filling factor, to quantify the degree to which an EMG signal has been built-up. This factor is calculated from the ratio of two non-central moments of the rectified EMG signal. The curve of the EMG filling factor as a function of the mean rectified amplitude shows a progressive and mostly linear increase during early recruitment, and saturation is observed when the EMG signal distribution becomes approximately Gaussian. Having presented the analytical tools used to derive the EMG PDF, we demonstrate the usefulness of the EMG filling factor and curve in studies with both simulated signals and real signals obtained from the tibialis anterior muscle of 10 subjects. Both simulated and real EMG filling curves start within the 0.2 to 0.35 range and rapidly rise towards 0.5 (Laplacian) before stabilizing at around 0.637 (Gaussian). Filling curves for the real signals consistently followed this pattern (100% repeatability within trials in 100% of the subjects). The theory of EMG signal filling derived in this work provides (a) an analytically consistent derivation of the EMG PDF as a function of motor unit potentials and motor unit firing patterns; (b) an explanation of the change in the EMG PDF according to degree of muscle contraction; and (c) a way (the EMG filling factor) to quantify the degree to which an EMG signal has been built-up.
  • PublicationOpen Access
    The contribution of the tendon electrode to M-wave characteristics in the biceps brachii, vastus lateralis and tibialis anterior
    (Wiley, 2023) Rodríguez Falces, Javier; Etxaleku, Saioa; Trajano, Gabriel S.; Setuain Chourraut, Igor; Ciencias de la Salud; Ingeniería Eléctrica, Electrónica y de Comunicación; Osasun Zientziak; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren
    In some compound muscle action potentials (M waves) recorded using the belly–tendon configuration, the tendon electrode makes a noticeable contribution to the M wave. However, this finding has only been demonstrated in some hand and foot muscles. Here, we assessed the contribution of the tendon potential to the amplitude of the vastus lateralis, biceps brachii and tibialis anterior M waves, and we also examined the role of this tendon potential in the shoulder-like feature appearing in most M waves. M waves were recorded separately at the belly and tendon locations of the vastus lateralis, biceps brachii and tibialis anterior from 38 participants by placing the reference electrode at a distant (contralateral) site. The amplitude of the M waves and the latency of their peaks and shoulders were measured. In the vastus lateralis, the tendon potential was markedly smaller in amplitude (∼75%) compared to the belly M wave (P = 0.001), whereas for the biceps brachii and tibialis anterior, the tendon and belly potentials had comparable amplitudes. In the vastus lateralis, the tendon potential showed a small positive peak coinciding in latency with the shoulder of the belly–tendon M wave, whilst in the biceps brachii and tibialis anterior, the tendon potential showed a clear negative peak which coincided in latency with the shoulder. The tendon potential makes a significant contribution to the belly–tendon M waves of the biceps brachii and tibialis anterior muscles, but little contribution to the vastus lateralis M waves. The shoulder observed in the belly–tendon M wave of the vastus lateralis is caused by the belly potential, the shoulder in the biceps brachii M wave is generated by the tendon potential, whereas the shoulder in the tibialis anterior M wave is caused by both the tendon and belly potentials.
  • PublicationOpen Access
    Masked least-squares averaging in processing of scanning-EMG recordings with multiple-discharges
    (Springer, 2020) Corera Orzanco, Íñigo; Malanda Trigueros, Armando; Rodríguez Falces, Javier; Navallas Irujo, Javier; Ingeniería Eléctrica y Electrónica; Ingeniaritza Elektrikoa eta Elektronikoa
    Removing artifacts from nearby motor units is one of the main objectives when processing scanning-EMG recordings. Methods such as median filtering or masked least-squares smoothing (MLSS) can be used to eliminate artifacts in recordings with just one discharge of the motor unit potential (MUP) at each location. However, more effective artifact removal can be achieved if several discharges per position are recorded. In this case, processing usually involves averaging the discharges available at each position and then applying a median filter in the spatial dimension. The main drawback of this approach is that the median filter tends to distort the signal waveform. In this paper, we present a new algorithm that operates on multiple discharges simultaneously and in the spatial dimension. We refer to this algorithm as the multi masked least-squares smoothing (MMLSS) algorithm: an extension of the MLSS algorithm for the case of multiple discharges. The algorithm is tested using simulated scanning-EMG signals in different recording conditions, i.e., at different levels of muscle contraction and for different numbers of discharges per position. Results demonstrate that the algorithm eliminates artifacts more effectively than any previously available method and does so without distorting the waveform of the signal.
  • PublicationOpen Access
    M-wave changes caused by brief voluntary and stimulated isometric contractions
    (Springer, 2023) Rodríguez Falces, Javier; Malanda Trigueros, Armando; Navallas Irujo, Javier; Place, Nicolas; Ingeniería Eléctrica, Electrónica y de Comunicación; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren; Universidad Pública de Navarra / Nafarroako Unibertsitate Publikoa
    Introduction Under isometric conditions, the increase in muscle force is accompanied by a reduction in the fbers’ length. The efects of muscle shortening on the compound muscle action potential (M wave) have so far been investigated only by computer simulation. This study was undertaken to assess experimentally the M-wave changes caused by brief voluntary and stimulated isometric contractions. Methods Two diferent methods of inducing muscle shortening under isometric condition were adopted: (1) applying a brief (1 s) tetanic contraction and (2) performing brief voluntary contractions of diferent intensities. In both methods, supramaximal stimulation was applied to the brachial plexus and femoral nerves to evoke M waves. In the frst method, electrical stimulation (20 Hz) was delivered with the muscle at rest, whereas in the second, stimulation was applied while participants performed 5-s stepwise isometric contractions at 10, 20, 30, 40, 50, 60, 70, and 100% MVC. The amplitude and duration of the frst and second M-wave phases were computed. Results The main fndings were: (1) on application of tetanic stimulation, the amplitude of the M-wave frst phase decreased (~10%, P<0.05), that of the second phase increased (~50%, P<0.05), and the M-wave duration decreased (~20%, P<0.05) across the frst fve M waves of the tetanic train and then plateaued for the subsequent responses; (2) when superimposing a single electrical stimulus on muscle contractions of increasing forces, the amplitude of the M-wave frst phase decreased (~20%, P<0.05), that of the second phase increased (~30%, P<0.05), and M-wave duration decreased (~30%, P<0.05) as force was raised from 0 to 60–70% MVC force. Conclusions The present results will help to identify the adjustments in the M-wave profle caused by muscle shortening and also contribute to diferentiate these adjustments from those caused by muscle fatigue and/or changes in Na+–K+ pump activity.
  • PublicationOpen Access
    The filling factor of the sEMG signal at low contraction forces in the quadriceps muscles is influenced by the thickness of the subcutaneous layer
    (Frontiers Media, 2023) Rodríguez Falces, Javier; Malanda Trigueros, Armando; Mariscal Aguilar, Cristina; Navallas Irujo, Javier; Ingeniería Eléctrica, Electrónica y de Comunicación; Institute of Smart Cities - ISC; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren
    Introduction: It has been shown that, for male subjects, the sEMG activity at low contraction forces is normally 'pulsatile', i.e., formed by a few large-amplitude MUPs, coming from the most superficial motor units. The subcutaneous layer thickness, known to be greater in females than males, influences the electrode detection volume. Here, we investigated the influence of the subcutaneous layer thickness on the type of sEMG activity (pulsatile vs. continuous) at low contraction forces. Methods: Voluntary surface EMG signals were recorded from the quadriceps muscles of healthy males and females as force was gradually increased from 0% to 40% MVC. The sEMG filling process was examined by measuring the EMG filling factor, computed from the non-central moments of the rectified sEMG signal. Results: 1) The sEMG activity at low contraction forces was ¿continuous¿ in the VL, VM and RF of females, whereas this sEMG activity was ¿pulsatile¿ in the VL and VM of males. 2) The filling factor at low contraction forces was lower in males than females for the VL (p = 0.003) and VM (p = 0.002), but not for the RF (p = 0.54). 3) The subcutaneous layer was significantly thicker in females than males for the VL (p = 0.001), VM (p = 0.001), and RF (p = 0.003). 4) A significant correlation was found in the vastus muscles between the subcutaneous layer thickness and the filling factor (p < 0.05). Discussion: The present results indicate that the sEMG activity at low contraction forces in the female quadriceps muscles is 'continuous' due to the thick subcutaneous layer of these muscles, which impedes an accurate assessment of the sEMG filling process.
  • PublicationOpen Access
    Automatic jitter measurement in needle-detected motor unit potential trains
    (Elsevier, 2022) Malanda Trigueros, Armando; Stashuk, Daniel W.; Navallas Irujo, Javier; Rodríguez Falces, Javier; Rodríguez Carreño, Ignacio; Valle, César; Garnés Camarena, Óscar; Ingeniería Eléctrica, Electrónica y de Comunicación; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren; Universidad Pública de Navarra / Nafarroako Unibertsitate Publikoa
    In an active motor unit (MU), the time intervals between the firings of its muscle fibers vary across successive MU activations. This variability is called jitter and is increased in pathological processes that affect the neuromuscular junctions or terminal axonal segments of MUs. Traditionally, jitter has been measured using single fiber electrodes (SFEs) and a difficult and subjective manual technique. SFEs are expensive and reused, implying a potential risk of patient infection; so, they are being gradually substituted by safer, disposable, concentric needle electrodes (CNEs). As CNEs are larger, voltage contributions from individual fibers of a MU are more difficult to detect, making jitter measurement more difficult. This paper presents an automatic method to estimate jitter from trains of motor unit potentials (MUPs), for both SFE and CNE records. For a MUP train, segments of MUPs generated by single muscle fibers (SF MUP segments) are found and jitter is measured between pairs of these segments. Segments whose estimated jitter values are not reliable, according to several SF MUP segment characteristics, are excluded. The method has been tested in several simulation studies that use mathematical models of muscle fiber potentials. The results are very satisfactory in terms of jitter estimation error (less than 10% in most of the cases studied) and mean number of valid jitter estimates obtained per simulated train (greater than 1.0 in many of the cases and less than 0.5 only in the most complicated). A preliminary study with real signals was also performed, using 19 MUP trains from 3 neuropathic patients. Jitter measurements obtained by the automatic method were compared with those extracted from a commercial system (Keypoint) and the edition and supervision of an expert electromyographer. From these measurements 63% were taken from equivalent interval pair sites within the time span of the MUP trains and, as such, were considered as compatible measurements. Differences in jitter of these compatible measurements were very low (mean value of 1.3 μs, mean of absolute differences of 2.97 μs, 25% and 75% percentile intervals of − 0.85 and 3.82 μs, respectively). Although new tests with larger number of real recordings are still required, the method seems promising for clinical practice.
  • PublicationOpen Access
    Sarcolemmal excitability, M-Wave changes, and conduction velocity during a sustained low-force contraction
    (Frontiers Media, 2021) Rodríguez Falces, Javier; Place, Nicolas; Ingeniería Eléctrica, Electrónica y de Comunicación; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren
    This study was undertaken to investigate whether sarcolemmal excitability is impaired during a sustained low-force contraction [10% maximal voluntary contraction (MVC)] by assessing muscle conduction velocity and also by analyzing separately the first and second phases of the muscle compound action potential (M wave). Twenty-one participants sustained an isometric knee extension of 10% MVC for 3min. M waves were evoked by supramaximal single shocks to the femoral nerve given at 10-s intervals. The amplitude, duration, and area of the first and second M-wave phases were computed. Muscle fiber conduction velocity, voluntary surface electromyographic (EMG), perceived effort, MVC force, peak twitch force, and temperature were also recorded. The main findings were: (1) during the sustained contraction, conduction velocity remained unchanged. (2) The amplitude of the M-wave first phase decreased for the first ~30s (−7%, p<0.05) and stabilized thereafter, whereas the second phase amplitude increased for the initial ~30s (+7%, p<0.05), before stabilizing. (3) Both duration and area decreased steeply during the first ~30s, and then more gradually for the rest of the contraction. (4) During the sustained contraction, perceived effort increased fivefold, whereas knee extension EMG increased by ~10%. (5) Maximal voluntary force and peak twitch force decreased (respectively, −9% and −10%, p<0.05) after the low-force contraction. Collectively, the present results indicate that sarcolemmal excitability is well preserved during a sustained 10% MVC task. A depression of the M-wave first phase during a low-force contraction can occur even in the absence of changes in membrane excitability. The development of fatigue during a low-force contraction can occur without alteration of membrane excitability.