Person:
Gubía Villabona, Eugenio

Loading...
Profile Picture

Email Address

Birth Date

Research Projects

Organizational Units

Job Title

Last Name

Gubía Villabona

First Name

Eugenio

person.page.departamento

ORCID

0000-0002-0067-1715

person.page.upna

1768

Name

Search Results

Now showing 1 - 3 of 3
  • PublicationOpen Access
    Robust active damping strategy for DFIG wind turbines
    (IEEE, 2021) Rosado Galparsoro, Leyre; Samanes Pascual, Javier; Gubía Villabona, Eugenio; López Taberna, Jesús; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren; Institute of Smart Cities - ISC; Ingeniería Eléctrica, Electrónica y de Comunicación
    Doubly fed induction generators (DFIGs) with an LCL filter are widely used for wind power generation. In these energy conversion systems, there is an interaction between the grid-side converter (GSC) and the rotor-side converter (RSC) control loops, the generator and the LCL filter that must be properly modeled. Such interaction between the GSC and the RSC proves to have a significant influence on the stability. Several active damping (AD) methods for grid-connected converters with an LCL filter have been proposed, nevertheless, the application of these techniques to a DFIG wind turbine is not straightforward, as revealed in this article. To achieve a robust damping irrespective of the grid inductance, this article proposes an AD strategy based on the capacitor current feedback and the adjustment of the control delays to emulate a virtual impedance, in parallel with the filter capacitor, with a dominant resistive component in the range of possible resonance frequencies. This work also proves that, by applying the AD strategy in both converters simultaneously, the damping of the system resonant poles is maximized when a specific value of the grid inductance is considered. Experimental results show the interaction between the GSC and the RSC and validate the proposed AD strategy. © 1986-2012 IEEE.
  • PublicationOpen Access
    Capacitor current feedback active damping with lagged compensator for DFIG wind turbines with LCL filter
    (IEEE, 2020) Rosado Galparsoro, Leyre; Samanes Pascual, Javier; Gubía Villabona, Eugenio; López Taberna, Jesús; Ingeniaritza Elektrikoa eta Elektronikoa; Institute of Smart Cities - ISC; Ingeniería Eléctrica y Electrónica
    Several active damping strategies have been proposed in the literature for grid-connected converters with LCL filter but there are not specific strategies for DFIG wind turbines. In this system, there is an interaction between the two converters of the back-to-back conversion structure, which must be properly modeled in order to design effective damping strategies for the LCL filter resonant poles. This paper proposes a robust active damping strategy for DFIG wind turbines with LCL filter that considers the special features of this system. In this technique the filter capacitor current is fed back through a lag compensator that adjusts the delay of the feedback loop to emulate a virtual impedance that has dominant resistive behavior in the range of possible resonance frequencies. It is shown that a similar damping of the LCL filter resonance is achieved when the strategy isimplemented in either of the two converters.
  • PublicationOpen Access
    Selective harmonic mitigation: limitations of classical control strategies and benefits of model predictive control
    (IEEE, 2023) Rosado Galparsoro, Leyre; Samanes Pascual, Javier; Gubía Villabona, Eugenio; López Taberna, Jesús; Ingeniería Eléctrica, Electrónica y de Comunicación; Institute of Smart Cities - ISC; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren; Universidad Pública de Navarra / Nafarroako Unibertsitate Publikoa
    Selective harmonic mitigation pulsewidth modulation (SHMPWM) combined with model predictive control (MPC) is a promising approach for grid-connected power converters. SHMPWM can guarantee grid code compliance in steady state, e.g. grid harmonic injection, with a reduced output converter filter, while MPC improves dynamic response and allows grid code compliance in the event of grid transients. This paper presents a survey of the MPC strategies already published in the literature developed for their use with SHMPWM. The existing strategies fall into two categories: direct model predictive control with an implicit selective harmonic mitigation modulator, and direct model predictive control based on finite control set (FCS-MPC). One representative control strategy of each group is compared to each other and to the performance of classical proportional- integral (PI) controllers combined with SHMPWM. The goal is to identify the potential benefits of MPC for grid-connected power converters, and determine the main advantages and limitations of the two selected state-of-the-art control strategies. Their performance is assessed through Hardware-in-the-Loop (HIL) experimental results in terms of real-time implementation, harmonic content grid code compliance, dynamic response and performance under grid transients.