Person: Bariáin Aisa, Cándido
Loading...
Email Address
person.page.identifierURI
Birth Date
Research Projects
Organizational Units
Job Title
Last Name
Bariáin Aisa
First Name
Cándido
person.page.departamento
Ingeniería Eléctrica y Electrónica
person.page.instituteName
ORCID
0000-0003-2865-2855
person.page.upna
289
Name
2 results
Search Results
Now showing 1 - 2 of 2
Publication Open Access 46-km-long Raman amplified hybrid double-bus network with point and distributed Brillouin sensors(IEEE, 2012) Fernández Vallejo, Montserrat; Olier Aguado, David; Zornoza Indart, Ander; Pérez Herrera, Rosa Ana; Díaz Lucas, Silvia; Elosúa Aguado, César; Bariáin Aisa, Cándido; Loayssa Lara, Alayn; López-Amo Sáinz, Manuel; Ingeniería Eléctrica y Electrónica; Ingeniaritza Elektrikoa eta ElektronikoaWe experimentally demonstrate a 46-km hybrid network that combine point and distributed Brillouin sensors. The proposed sensor network multiplexes low-cost intensity point sensors based on fiber-optic tapers, which are able to measure vibrations in the 0.01 to 50 Hz frequency range. The sensor network with a double-bus is a low noise configuration, which offers a higher optical signal to noise ratio and dynamic range than a single-bus. Thus, the number of sensors to be multiplexed could increase or we could reach further distances. The system also deploys remote distributed Raman amplification to extend the sensing range.Publication Open Access Long-range hybrid network with point and distributed Brillouin sensors using Raman amplification(Optical Society of America, 2010) Zornoza Indart, Ander; Pérez Herrera, Rosa Ana; Elosúa Aguado, César; Díaz Lucas, Silvia; Bariáin Aisa, Cándido; Loayssa Lara, Alayn; López-Amo Sáinz, Manuel; Ingeniería Eléctrica y Electrónica; Ingeniaritza Elektrikoa eta ElektronikoaWe propose a novel concept for hybrid networks that combine point and distributed Brillouin sensors in a cost-effective architecture that also deploys remote distributed Raman amplification to extend the sensing range. A 46-km proof-of-concept network is experimentally demonstrated integrating point vibration sensors based on fiber Bragg gratings and tapers with distributed temperature sensing along the network bus. In this network the use of Raman amplification to compensate branching and fiber losses provides a temperature resolution of 0.7°C and 13 m. Moreover, it was possible to obtain good optical signal to noise ratio in the measurements from the four point vibration sensors that were remotely multiplexed in the network. These low-cost intensity sensors are able to measure vibrations in the 0.1 to 50 Hz frequency range, which are important in the monitoring of large infrastructures such as pipelines.