Pérez Herrera, Rosa Ana

Loading...
Profile Picture

Email Address

Birth Date

Job Title

Last Name

Pérez Herrera

First Name

Rosa Ana

person.page.departamento

Ingeniería Eléctrica, Electrónica y de Comunicación

person.page.instituteName

ISC. Institute of Smart Cities

person.page.observainves

person.page.upna

Name

Search Results

Now showing 1 - 10 of 11
  • PublicationOpen Access
    Linear fiber laser configurations for optical concentration sensing in liquid solutions
    (MDPI, 2024) Soares, Liliana; Pérez Herrera, Rosa Ana; Novais, Susana; Ferreira, António; Silva, Susana; Frazão, Orlando; Ingeniería Eléctrica, Electrónica y de Comunicación; Ingeniaritza Elektrikoa, Elektronikoa eta Telekomunikazio Ingeniaritza; Institute of Smart Cities - ISC
    In this study, different configurations based on linear fiber lasers were proposed and experimentally demonstrated to measure the concentration of liquid solutions. Samples of paracetamol liquid solutions with different concentrations, in the range from 52.61 to 201.33 g/kg, were used as a case-study. The optical gain was provided by a commercial bidirectional Erbium-Doped Fiber Amplifier (EDFA) and the linear cavity was obtained using two commercial Fiber Bragg Gratings (FBGs). The main difference of each configuration was the coupling ratio of the optical coupler used to extract the system signal. The sensing head corresponded to a Single-Mode Fiber (SMF) tip that worked as an intensity sensor. The results reveal that, despite the optical coupler used (50:50, 60:40, 70:30 or 80:20), all the configurations reached the laser condition, however, the concentration sensing was only possible using a laser drive current near to the threshold value. The configurations using a 70:30 and an 80:20 optical coupler allowed paracetamol concentration measurements with a higher sensitivity of (−3.00 ± 0.24) pW/(g/kg) to be performed. In terms of resolution, the highest value obtained was 1.75 g/kg, when it was extracted at 20% of the output power to the linear cavity fiber laser configuration.
  • PublicationOpen Access
    Low noise dual-wavelength erbium fiber laser in single-longitudinal-mode operation
    (Springer, 2012) Rota Rodrigo, Sergio; Pérez Herrera, Rosa Ana; Fernández Vallejo, Montserrat; López-Amo Sáinz, Manuel; Ingeniería Eléctrica y Electrónica; Ingeniaritza Elektrikoa eta Elektronikoa
    A new stable dual-wavelength fiber-ring laser based on erbium-doped fiber amplification is reported. The laser is based on ring resonators and employs fiber Bragg gratings to select the operation wavelengths. The topology of the laser has a significant influence in its performance: allowing an independent control of the losses for both lasing wavelengths and achieving a low noise configuration. As a result, it is experimentally demonstrated that both emission lines work in single-longitudinal-mode operation and the topology offers a better stability and higher optical signalto-noise ratios than similar configurations.
  • PublicationOpen Access
    Influence of saturable absorbers on fiber ring laser sensors
    (SPIE, 2017) Rodríguez Cobo, Luis; Quintela, M. A.; Ruiz Lombera, Rubén; Pérez Herrera, Rosa Ana; López-Amo Sáinz, Manuel; López Higuera, José Miguel; Ingeniaritza Elektrikoa eta Elektronikoa; Institute of Smart Cities - ISC; Ingeniería Eléctrica y Electrónica
    In this work, a fiber ring laser sensor has been employed to analyze the influence of passive Er-doped fiber acting as saturable absorber. Lasing modes of fiber ring lasers can be reduced by properly locating a saturable absorber that narrows the spectral width of the FBG that selects the lasing wavelength. Employing commercial Er-doped fiber, different configurations have been evaluated, reaching the SLM regime on a ring cavity of several meters. Thus, the achieved strain response of the whole sensor behaves at its mirror FBG, exhibiting linear response to strain.
  • PublicationOpen Access
    Optimizing graphene oxide saturable absorbers for short pulse generation in fiber lasers: characterization and aging assessment
    (SPIE, 2024-06-20) Monteiro, Catarina S.; Pérez Herrera, Rosa Ana; Silva, Nuno A.; Silva, Susana; Frazão, Orlando; Ingeniería Eléctrica, Electrónica y de Comunicación; Ingeniaritza Elektrikoa, Elektronikoa eta Telekomunikazio Ingeniaritza; Institute of Smart Cities - ISC
    The generation of short pulses in fiber lasers using saturable absorbers made of graphene oxide (GO), focusing on film thickness, was studied and optimized. The saturable absorber comprised a GO thin film deposited onto a single-mode fiber using the spray coating technique. Water-dispersed GO with a concentration of 4 mg/mL, characterized by a high proportion of monolayer flakes, was employed. This thin film was integrated into a cavity ring laser featuring an erbium-doped fiber amplifier (EDFA), resulting in a fiber laser emitting at a central emission wavelength of approximately 1564 nm and having a total cavity length of approximately 120 m. By controlling intracavity polarization, short-pulsed light was generated through mode-locking, Q switching, or a combination of both regimes. This work presents a comprehensive characterization of the cavity ring laser operating under the mode-locking regime. It encompasses an analysis of the spectral behavior, focusing on the evolution of the Kelly¿s sidebands with increasing pump power, as well as an assessment of its temporal stability. Moreover, the effects of the aging of the saturable absorber material were studied after a time period of 6 months after the fabrication. It was observed that the general characteristics of spectral signal of the laser were maintained, with long-term stability.
  • PublicationOpen Access
    Short pulse generation in erbium-doped fiber lasers using graphene oxide as a saturable absorber
    (Science and Technology Publications, Lda., 2023) Monteiro, Catarina S.; Pérez Herrera, Rosa Ana; Silva, Susana; Frazão, Orlando; Ingeniería Eléctrica, Electrónica y de Comunicación; Ingeniaritza Elektrikoa, Elektronikoa eta Telekomunikazio Ingeniaritza; Institute of Smart Cities - ISC
    The use of graphene oxide (GO) as a saturable absorber for short pulses generation in an Erbium-doped fiber laser was studied and demonstrated. The saturable absorber consisted of a thin GO film, with a high concentration of monolayer GO flakes, spray-coated on the end face of a ferrule-connected fiber. By including the saturable absorber in the laser cavity and controlling the intra-cavity polarization, the generation of short-pulsed light was achieved under mode-locking and Q-switching operations. Under mode-locking operation, it was observed a pulse train with a fundamental repetition rate of 1.48 MHz, with a working wavelength centered at 1564.4 nm. In the Q-switch operation, a pulse train with a 12.7 kHz repetition rate and a 14.3 µs pulse duration was attained for a 230-mA pump current. Further investigation showed a linear dependence of the repetition rate with the pump power, attaining frequencies between 12.7 and 14.4 kHz.
  • PublicationOpen Access
    Wavelength-switchable L-band fiber laser assisted by random reflectors
    (EDP Open, 2023) Pérez Herrera, Rosa Ana; Roldán Varona, Pablo; Sánchez González, Arturo; Rodríguez Cobo, Luis; López Higuera, José Miguel; López-Amo Sáinz, Manuel; Ingeniería Eléctrica, Electrónica y de Comunicación; Institute of Smart Cities - ISC; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren
    A wavelength-switchable L-band erbium-doped fiber laser (EDFL) assisted by an artificially controlled backscattering (ACB) fiber reflector is here presented. This random reflector was inscribed by femtosecond (fs) laser direct writing on the axial axis of a multimode fiber with 50 lm core and 125 lm cladding with a length of 17 mm. This microstructure was placed inside a surgical syringe to be positioned in the center of a high-precision rotation mount to accurately control its angle of rotation. Only by rotating this mount, three different output spectra were obtained: a single wavelength lasing centered at 1574.75 nm, a dual wavelength lasing centered at 1574.75 nm and 1575.75 nm, and a single wavelength lasing centered at 1575.5 nm. All of them showed an optical signal-to-noise ratio (OSNR) of around 60 dB when pumped at 300 mW
  • PublicationOpen Access
    Measurement of paracetamol concentration using a fiber laser system
    (IEEE, 2023) Soares, Liliana; Pérez Herrera, Rosa Ana; Novais, Susana; Ferreira, António; Frazão, Orlando; Silva, Susana; Ingeniería Eléctrica, Electrónica y de Comunicación; Institute of Smart Cities - ISC; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren
    A linear fiber laser system for measurements of paracetamol concentration is experimentally demonstrated. The cavity is based on a fiber loop mirror and an FBG centered at 1567.8 nm. The sensing head corresponds to a refractometric sensor, whose which principle of operation is based on Fresnel reflection in the fiber tip (FBG side). The system works at detected variations of paracetamol concentrations with a sensitivity of [8.74± 0.34)× 10-5] µW/(g/kg) and a resolution of 2.77 g/kg. The results prove that the fiber laser system could be an asset for processing industries, specifically for non-invasive and real-time measurements of concentration.
  • PublicationOpen Access
    Fiber optic sensor networks
    (Elsevier, 2013) Pérez Herrera, Rosa Ana; López-Amo Sáinz, Manuel; Ingeniería Eléctrica y Electrónica; Ingeniaritza Elektrikoa eta Elektronikoa
    One of the main goals in fiber optic sensor technology is to multiplex together a high number of sensorsin the same network in order to share expensive terminal equipment and develop a system including multiple measuring points. Different kind of multiplexing networks for fiber optic sensors will be described and compared here, including networks using optical amplification and lasing multiplexing systems. State of the art in multiplexed and distributed sensor networks is also shown, focused on robust, remote and distributed Brillouin networks.
  • PublicationOpen Access
    Paracetamol concentration-sensing scheme based on a linear cavity fiber laser configuration
    (Elsevier, 2023) Soares, Liliana; Pérez Herrera, Rosa Ana; Novais, Susana; Ferreira, António; Frazão, Orlando; Silva, Susana; Ingeniería Eléctrica, Electrónica y de Comunicación; Institute of Smart Cities - ISC; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren
    A paracetamol concentration-sensing scheme based on a linear cavity fiber laser configuration is demonstrated experimentally. The laser cavity has a fiber sensor at one end, that allows refractive index measurements. The refractometer consists of a cleaved fiber tip combined with an FBG functioning as a reflecting mirror. The combination of a fiber loop mirror at the other end allows to reflect all the light from the FBG and refractometer, forming a linear cavity. By measuring the intensity variation of the Fresnel reflection at the fiber-to-liquid interface, the measured concentration is linear and have a concentration sensitivity of -8.74±0.34×10-5 µW/(g/kg), over a range of 52.61 to 219.25 g/kg, and with a resolution of 2.77 g/kg. The results obtained present high stability and prove the potential of the fiber laser system to performed real-time measurements of concentration, in a non-invasive way.
  • PublicationOpen Access
    Láseres de fibra óptica basados en reflectores clásicos, estrechados y microperforados
    (SEDOPTICA, 2021) Sánchez González, Arturo; Pérez Herrera, Rosa Ana; Roldán Varona, Pablo; Rodríguez Cobo, Luis; López Higuera, José Miguel; López-Amo Sáinz, Manuel; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren; Institute of Smart Cities - ISC; Ingeniería Eléctrica, Electrónica y de Comunicación; Universidad Pública de Navarra / Nafarroako Unibertsitate Publikoa, PJUPNA1928
    En este trabajo se presenta un estudio comparativo entre distintos láseres de fibra óptica altamente dopada con erbio, con cavidades lineales conformadas tanto por reflectores puntuales clásicos como reflectores distribuidos. El estudio analiza experimentalmente las principales prestaciones de cada configuración, destacando las mejoras en estabilidad de emisión y estrechamiento de línea alcanzadas con fibras estrechadas microperforadas.