Matías Maestro, Ignacio
Loading...
Email Address
person.page.identifierURI
Birth Date
Job Title
Last Name
Matías Maestro
First Name
Ignacio
person.page.departamento
Ingeniería Eléctrica, Electrónica y de Comunicación
person.page.instituteName
ISC. Institute of Smart Cities
ORCID
person.page.observainves
person.page.upna
Name
- Publications
- item.page.relationships.isAdvisorOfPublication
- item.page.relationships.isAdvisorTFEOfPublication
- item.page.relationships.isAuthorMDOfPublication
63 results
Search Results
Now showing 1 - 10 of 63
Publication Embargo Photoisomerization-induced LMR shift for UV radiation detection(Elsevier, 2024) Gallego Martínez, Elieser Ernesto; Ruiz Zamarreño, Carlos; Matías Maestro, Ignacio; Ingeniería Eléctrica, Electrónica y de Comunicación; Institute of Smart Cities - ISC; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio IngeniaritzarenThis work presents an optical sensor for ultraviolet radiation (UV) detection, based on the combined effects of Lossy Mode Resonance (LMR) in the mid infrared (MIR) spectral region and the photoisomerization of a polymeric dye coating. LMR was obtained by means of a sputtered SnO2 thin film on a tetrafluoroethylene-perfluoro (or alkoxy Vinyl Ether, PFA) substrate, along with a photo sensitive coating based on poly R-478. Obtained devices shown response and recovery times of 12 and 43 s, respectively, for an UV excitation of 71 mW at 365 nm. Sensitivity as a function of the excitation wavelength was studied with the highest value of 26 nm/mW obtained at 280 nm. For this excitation wavelength, the limit of detection (LoD) obtained was 0.024 mW. Four different excitation wavelengths were used to cover all UV regions (280, 310, 365 and 395 nm). All measurements were performed at room temperature and humidity (25 ¿C ± 1 ¿C and 13% R.H. ± 2% R.H. respectively). As far as we know, it is the first time that the LMR effect has been recognized in combination with a photoisomerization process.Publication Open Access Surface exciton polariton resonances (SEPR)-based sensors(Elsevier, 2023) Vitoria Pascual, Ignacio; Ruiz Zamarreño, Carlos; Ozcariz Celaya, Aritz; Imas González, José Javier; Del Villar, Ignacio; Matías Maestro, Ignacio; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren; Institute of Smart Cities - ISC; Ingeniería Eléctrica, Electrónica y de ComunicaciónA new type of resonance in the development of sensors using long-range surface exciton polariton (LRSEP) phenomena has been coined: surface exciton plasmon resonance (SEPR). The resonance was obtained in the reflected spectrum of a Kretschmann-Raether setup with a two-coupled-interface structure composed of 412 nm magnesium fluoride and 50 nm chromium thin films. The roles of different parameters such as thicknesses of the films and the incidence angles have been simulated. Some preliminary experimental results show a promising performance with a shift of the resonance central wavelength with changes in the incidence angle of -136.52 nm/° and a sensitivity of 23,221 nm/refractive index unit.Publication Open Access Ammonia gas optical sensor based on lossy mode resonances(IEEE, 2023) Armas, Dayron; Zubiate Orzanco, Pablo; Ruiz Zamarreño, Carlos; Matías Maestro, Ignacio; Ingeniería Eléctrica, Electrónica y de Comunicación; Institute of Smart Cities - ISC; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio IngeniaritzarenThis letter presents the fabrication and characterization of an ammonia (NH 3) gas optical sensor based on lossy mode resonances (LMRs). A chromium (III) oxide (Cr 2 O 3) thin film deposited onto a planar waveguide was used as LMR supporting coating. The obtained LMR shows a maximum attenuation wavelength or resonance wavelength centered at 673 nm. The optical properties of the coating can be modified as a function of the presence and concentration of NH 3 in the external medium. Consequently, the refractive index of the Cr 2 O 3 thin film will change, producing a red-shift of the resonance wavelength. Obtained devices were tested for different concentrations of NH 3 as well as repetitive cycles. Concentrations as low as 10 ppbv of NH 3 were detected at room temperature. Machine learning regression models were used to mitigate the cross-sensitivity of the device under temperature and humidity fluctuations.Publication Open Access Mode transition during deposition of nanoscale ITO coatings on tilted fiber Bragg gratings(Optica Publishing Group, 2022) Imas González, José Javier; Albert, Jacques; Del Villar, Ignacio; Ozcariz Celaya, Aritz; Ruiz Zamarreño, Carlos; Matías Maestro, Ignacio; Ingeniería Eléctrica, Electrónica y de Comunicación; Institute of Smart Cities - ISC; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio IngeniaritzarenThe mode transition phenomenon is experimentally demonstrated in tilted fiber Bragg gratings (TFBG) through the deposition of an indium tin oxide (ITO) thin film employing a DC sputtering machine.Publication Open Access Femtomolar detection by nanocoated fiber label-free biosensors(American Chemical Society, 2018) Chiavaioli, Francesco; Zubiate Orzanco, Pablo; Del Villar, Ignacio; Ruiz Zamarreño, Carlos; Giannetti, Ambra; Tombelli, Sara; Trono, Cosimo; Arregui San Martín, Francisco Javier; Matías Maestro, Ignacio; Baldini, Francesco; Institute of Smart Cities - ISC; Ingeniería Eléctrica y Electrónica; Ingeniaritza Elektrikoa eta Elektronikoa; Gobierno de Navarra / Nafarroako GobernuaThe advent of optical fibre-based biosensors combined with that of nanotechnologies has provided an oppor-tunity for developing in situ, portable, lightweight, versatile and high-performance optical sensing platforms. We report on the generation of lossy mode resonances by the deposition of nm-thick metal oxide films on optical fibres, which makes it possible to measure precisely and accurately the changes in optical properties of the fibre-surrounding medium with very high sensitivity compared to other technology platforms, such as long period gratings or surface plasmon resonances, the gold standard in label-free and real-time biomolecular interaction analysis. This property, combined with the application of specialty structures such as D-shaped fibres, permits enhancing the light-matter interaction. SEM and TEM imaging together with X-EDS tool have been utilised to characterise the two films used, i.e. indium tin oxide and tin dioxide. More-over, the experimental transmission spectra obtained after the deposition of the nanocoatings have been numerically cor-roborated by means of wave propagation methods. With the use of a conventional wavelength interrogation system and ad-hoc developed microfluidics, the shift of the lossy mode resonance can be reliably recorded in response to very low analyte concentrations. Repeated experiments confirm a big leap in performance thanks to the capability to detect femtomolar concentrations in human serum, improving the detection limit by three orders of magnitude when compared with other fibre-based configurations. The biosensor has been regenerated several times by injecting sodium dodecyl sul-phate, which proves the capability of sensor to be reused.Publication Open Access High sensitive refractometers based on lossy mode resonances (LMRs) supported by ITO coated D-shaped optical fibers(Optical Society of America, 2015) Zubiate Orzanco, Pablo; Ruiz Zamarreño, Carlos; Del Villar, Ignacio; Matías Maestro, Ignacio; Arregui San Martín, Francisco Javier; Ingeniería Eléctrica y Electrónica; Ingeniaritza Elektrikoa eta ElektronikoaTin doped indium oxide (ITO) coatings fabricated onto D-shaped optical fibers are presented as the supporting medium for Lossy Mode Resonances (LMRs) generation. The characteristic geometry of ITO-coated D-shaped optical fibers enables to observe experimentally LMRs obtained with both TM and TE polarized light (LMRTM and LMRTE). This permits to obtain a maximum transmission decay of 36 dB with a LMR spectral width of 6.9 nm, improving that obtained in previous works, where the LMRs were a combination of an LMRTM and an LMRTE. Surrounding medium refractive index (SMRI) sensitivity characterization of LMRTM has been performed obtaining a maximum sensitivity of 8742 nm/RIU in the range 1.365-1.38 refractive index units (RIU) which overcomes that of surface plasmon resonance-based optical fiber devices presented in recent works.Publication Open Access Optical fiber refractometers based on indium tin oxide coatings with response in the visible spectral region(Elsevier, 2011) Ruiz Zamarreño, Carlos; López, S.; Hernáez Sáenz de Zaitigui, Miguel; Del Villar, Ignacio; Matías Maestro, Ignacio; Arregui San Martín, Francisco Javier; Ingeniería Eléctrica y Electrónica; Ingeniaritza Elektrikoa eta Elektronikoa; Gobierno de Navarra / Nafarroako GobernuaThis work presents the fabrication of optical fiber refractometers based on indium tin oxide (ITO) coatings with response in the visible spectral region. ITO thin-films have been sputtered by employing a rotating mechanism that enables the fabrication of smooth homogeneous coatings onto the optical fiber core. The ITO coated optical fiber devices present several resonances in the visible and infra-red region. These resonances show high optical power attenuations (more than 10 dB) in the visible spectral region, which produces changes in the colour of the output visible light. Therefore, since these resonances shift as a function of the surrounding medium refractive index (SMRI), it is feasible to determine the refractive index of the outer medium in contact with the ITO coating by simply monitoring the chromatic coordinates of the visible output light.Publication Open Access A fiber optic ammonia sensor using a universal pH indicator(MDPI, 2014) Rodríguez Rodríguez, Adolfo Josué; Ruiz Zamarreño, Carlos; Matías Maestro, Ignacio; Arregui San Martín, Francisco Javier; Cruz, René; May Arrioja, Daniel A.; Ingeniería Eléctrica y Electrónica; Ingeniaritza Elektrikoa eta ElektronikoaA universal pH indicator is used to fabricate a fiber optic ammonia sensor. The advantage of this pH indicator is that it exhibits sensitivity to ammonia over a broad wavelength range. This provides a differential response, with a valley around 500 nm and a peak around 650 nm, which allows us to perform ratiometric measurements. The ratiometric measurements provide not only an enhanced signal, but can also eliminate any external disturbance due to humidity or temperature fluctuations. In addition, the indicator is embedded in a hydrophobic and gas permeable polyurethane film named Tecoflex®. The film provides additional advantages to the sensor, such as operation in dry environments, efficient transport of the element to be measured to the sensitive area of the sensor, and prevent leakage or detachment of the indicator. The combination of the universal pH indicator and Tecoflex® film provides a reliable and robust fiber optic ammonia sensor.Publication Open Access LMR-based optical sensor for ethylene detection at visible and mid-infrared regions(IEEE, 2023) Gallego Martínez, Elieser Ernesto; Hualde Otamendi, Mikel; Ruiz Zamarreño, Carlos; Matías Maestro, Ignacio; Ingeniería Eléctrica, Electrónica y de Comunicación; Institute of Smart Cities - ISC; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren; Universidad Pública de Navarra / Nafarroako Unibertsitate PublikoaEthylene monitoring has long been a method of controlling the ripening of climacteric fruits, but it turns out that this gas is an important biomarker in biomedical applications. This work presents an optical gas sensor based on the lossy mode resonance (LMR) effect for ethylene detection in planar waveguide configuration. Two different approaches have been explored: one in the visible (VIS) spectral region and the second one in the mid infrared (MIR) region. Optical resonances have been achieved, in all cases, by means of sputtered tin oxide thin films. Response and recovery times were 54 and 246 s, respectively, for the sensor with the resonance in the VIS region, while the device operating in the MIR obtained response and recovery times of 19 and 47 s, respectively. The sensitivity during ethylene detection varied from 93.8 to 187.5 pm/ppm with the devices working in the VIS and MIR regions, respectively. According to the calibration curve, devices show an ethylene limit of detection (LOD) of 4.0058 and 0.6532 ppm in the VIS and MIR spectral regions, respectively, which finds applications in climacteric fruit ripening assessment as well as hemodialysis control. Cross sensitivity with humidity was also characterized for both devices.Publication Open Access Ultra-low detection limit lossy mode resonance-based fibre-optic biosensor(Optica Publishing Group, 2018) Chiavaioli, Francesco; Zubiate Orzanco, Pablo; Del Villar, Ignacio; Ruiz Zamarreño, Carlos; Giannetti, Ambra; Tombelli, Sara; Trono, Cosimo; Matías Maestro, Ignacio; Arregui San Martín, Francisco Javier; Baldini, Francesco; Ingeniería Eléctrica, Electrónica y de Comunicación; Ingeniaritza Elektrikoa, Elektronikoa eta Telekomunikazio Ingeniaritza; Institute of Smart Cities - ISCWe report on ultra-low detection limit lossy mode resonance-based fibre-optic biosensor coated with nm-thick tin dioxide film, which allows measuring fibre-surrounding medium changes with very high sensitivity for label-free and real-time biomolecular interaction analysis