Júdez Colorado, Aitor
Loading...
Email Address
person.page.identifierURI
Birth Date
Job Title
Last Name
Júdez Colorado
First Name
Aitor
person.page.departamento
Ingeniería Eléctrica y Electrónica
person.page.instituteName
ORCID
person.page.observainves
person.page.upna
Name
- Publications
- item.page.relationships.isAdvisorOfPublication
- item.page.relationships.isAdvisorTFEOfPublication
- item.page.relationships.isAuthorMDOfPublication
2 results
Search Results
Now showing 1 - 2 of 2
Publication Open Access High sensitivity fiber-optic liquid level sensor using biconical tapered fibers(Optical Society of America, 2018) Júdez Colorado, Aitor; Leandro González, Daniel; Pérez Herrera, Rosa Ana; Galarza Galarza, Marko; López-Amo Sáinz, Manuel; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren; Institute of Smart Cities - ISC; Ingeniería Eléctrica, Electrónica y de Comunicación; Universidad Pública de Navarra / Nafarroako Unibertsitate PublikoaA liquid level sensor is presented using a biconical tapered standard single-mode fiber, being its main characteristic an outstanding sensitivity for a low cost transducer. Temperature compensation is enabled with the same interrogation equipment.Publication Open Access Spatial-frequency multiplexing of high-sensitivity liquid level sensors based on multimode interference micro-fibers(Elsevier, 2020) Galarza Galarza, Marko; Pérez Herrera, Rosa Ana; Leandro González, Daniel; Júdez Colorado, Aitor; López-Amo Sáinz, Manuel; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren; Institute of Smart Cities - ISC; Ingeniería Eléctrica, Electrónica y de Comunicación; Universidad Pública de Navarra / Nafarroako Unibertsitate PublikoaThis paper shows a new fiber optic sensor multiplexed system for liquid level sensing. Biconical fibertapers converging at a 40 mm-long micro-fiber are used as transducers. The tapers are designed to providethe propagation of the two main cylindrical modes in the micro-fiber avoiding higher order modes ormodes with other symmetries. The liquid level is calculated in real time from the measurement of thefrequency and phase components of the spectral interference pattern of the submerged micro-fiber.The system is fully characterized by theoretical simulations in terms of the sensitivity as a function ofthe most responsive parameter, which is the width of the micro-fiber. Phase sensibilities of 3.7 rad/mmare experimentally obtained and values as high as 11.4 rad/mm are theoretically predicted. The strongdependence of the spatial frequency with the width of the micro-fiber has been used to multiplex threesensors in series in this domain. The maximum detected crosstalk between sensors is 0.2 rad/mm.