Designing a terahertz optical sensor based on helically twisted photonic crystal fiber for toxic gas sensing

Date

2025-01-17

Authors

Saberi, Hana
Pakarzadeh, Hassan

Director

Publisher

Springer Nature
Acceso abierto / Sarbide irekia
Artículo / Artikulua
Versión publicada / Argitaratu den bertsioa

Project identifier

Impacto

Abstract

A novel helically twisted photonic crystal fiber (PCF) is designed and proposed for sensing toxic gases with refractive indices ranging from 1.00 to 1.08. The PCF consists of twelve hollow pipes arranged circularly around the hollow core to support THz radiation propagation. Low-loss polymer Topas is used as the background material of cladding. The fiber is twisted 360 degrees over 50 cm to enhance anti-resonance in the THz region. The fundamental LP01 mode is analyzed using the finite-difference eigenmode (FDE) method. The sensor operates across four frequency bands (0.2 to 3.0 THz) with minimal transmission loss (similar to 10(-4) 1/cm). Key parameters such as refractive index sensitivity, relative sensitivity, resolution, and figure of merit (FOM) are evaluated. The average refractive index sensitivities are 1450, 2250, 3000, and 2550 for Bands 1 to 4, respectively, with 100% relative sensitivity across all bands. The sensor detects refractive index changes as small as 10(-4). The FOM, defined as the inverse of the full width at half maximum, exceeds 30 1/RIU, reaching up to 250 1/RIU due to sharp resonance peaks. Compared to other THz sensors, this design offers enhanced performance in sensing gases like SOx, NOx, and CO, while maintaining a simple structure.

Description

Keywords

Twisted fiber, Photonic crystal fiber, Terahertz sensor, Toxic gases

Department

Ingeniería Eléctrica, Electrónica y de Comunicación / Ingeniaritza Elektrikoa, Elektronikoa eta Telekomunikazio Ingeniaritza

Faculty/School

Degree

Doctorate program

item.page.cita

Sharif, V., Saberi, H., Pakarzadeh, H. (2025) Designing a terahertz optical sensor based on helically twisted photonic crystal fiber for toxic gas sensing. Scientific Reports, 15, 1-12. https://doi.org/10.1038/s41598-024-82704-0

item.page.rights

© The Author(s) 2025. This article is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License, which permits any non-commercial use, sharing, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if you modified the licensed material.

Licencia

Los documentos de Academica-e están protegidos por derechos de autor con todos los derechos reservados, a no ser que se indique lo contrario.