Andres, NievesPinto Fuste, Cristina LeyreLobera, JuliaLópez, Ana M.Palero, V. R.2021-04-072022-09-0120200030-399210.1016/j.optlastec.2020.106304https://academica-e.unavarra.es/handle/2454/39503Radial deformation of blood vessels has been measured by combining shape and deformation measurements. The difficulty of measuring both magnitudes simultaneously is related to the different order of magnitude. The veins have diameters up to 20 mm and suffer micrometric deformations due to cardiac movement. Temporal comparison of two-wavelength multiplexed holograms has been used for calculations. The radius value was calculated from the information of the vein shape, obtained by means of double wavelength holography, while the deformation of the vein has been measured with traditional holographic interferometry. In this work, both techniques have been combined using only one recording system. The technique has been tested in a latex tube and in a sheep aorta (ex-vivo). The experiments in both cases have been designed to simulate real patient situations. Differences found between the model and real vessels are presented in the paper.12p.application/pdfeng© 2020 Elsevier Ltd. This manuscript version is made available under the CC-BY-NC-ND 4.0Digital holographyDual wavelength holographyRadial deformation of blood vesselsShape of veinsDigital holography applied to simultaneously measure the shape and the radial deformation of a blood vessel (ex-vivo)info:eu-repo/semantics/articleinfo:eu-repo/semantics/openAccessAcceso abierto / Sarbide irekia