Impact of methods for data selection on the day-to-day reproducibility of resting metabolic rate assessed with four different metabolic carts
Date
2023Author
Version
Acceso abierto / Sarbide irekia
Type
Artículo / Artikulua
Version
Versión publicada / Argitaratu den bertsioa
Project Identifier
Impact
|
10.1016/j.numecd.2023.07.017
Abstract
Background and aims: Accomplishing a high day-to-day reproducibility is important to detect changes in resting metabolic rate (RMR) and respiratory exchange ratio (RER) that may be produced after an intervention or for monitoring patients’ metabolism over time. We aimed to analyze: (i) the influence of different methods for selecting indirect calorimetry data on RMR and RER assessments; and, (ii) ...
[++]
Background and aims: Accomplishing a high day-to-day reproducibility is important to detect changes in resting metabolic rate (RMR) and respiratory exchange ratio (RER) that may be produced after an intervention or for monitoring patients’ metabolism over time. We aimed to analyze: (i) the influence of different methods for selecting indirect calorimetry data on RMR and RER assessments; and, (ii) whether these methods influence RMR and RER day-to-day reproducibility. Methods and results: Twenty-eight young adults accomplished 4 consecutive RMR assessments (30-min each), using the Q-NRG (Cosmed, Rome, Italy), the Vyntus CPX (Jaeger-CareFusion, Höchberg, Germany), the Omnical (Maastricht Instruments, Maastricht, The Netherlands), and the Ultima CardiO2 (Medgraphics Corporation, St. Paul, Minnesota, USA) carts, on 2 consecutive mornings. Three types of methods were used: (i) short (periods of 5 consecutive minutes; 6e10, 11e15, 16e20, 21e25, and 26e30 min) and long time intervals (TI) methods (6e25 and 6 e30 min); (ii) steady state (SSt methods); and, (iii) methods filtering the data by thresholding from the mean RMR (filtering methods). RMR and RER were similar when using different methods (except RMR for the Vyntus and RER for the Q-NRG). Conversely, using different methods impacted RMR (all P 0.037) and/or RER (P 0.009) day-to-day reproducibility in all carts. The 6e25 min and the 6e30 min long TI methods yielded more reproducible measurements for all metabolic carts.
Conclusion: The 6e25 min and 6e30 min should be the preferred methods for selecting data, as they result in the highest day-to-day reproducibility of RMR and RER assessments. [--]
Subject
Between-days reproducibility,
Coefficient of variation,
Indirect calorimetry,
REE,
Reliability,
Resting energy expenditure
Publisher
Elsevier
Published in
Nutrition, Metabolism and Cardiovascular Diseases, 33(11), 2023
Departament
Universidad Pública de Navarra. Departamento de Ciencias de la Salud /
Nafarroako Unibertsitate Publikoa. Osasun Zientziak Saila /
Universidad Pública de Navarra/Nafarroako Unibertsitate Publikoa. Institute on Innovation and Sustainable Development in Food Chain - ISFOOD
Publisher version
Sponsorship
This work was supported by the Spanish Ministry of Economy and Competitiveness via Retos de la Sociedad grant DEP2016-79512-R (to JRR), and European Regional Development Funds (ERDF); Spanish Ministry of Education grant (FPU15/04059 to JMAA; FPU19/01609 to LJ-F; and FPU18/03357 to MD-M); the University of Granada Plan Propio de Investigación 2016-Excellence actions: Unit of Excellence on Exercise and Health (to JRR); the University of Granada Plan Propio 2020 and 2018 Programa Contratos-Puente (to JMA and GS-D, respectively), and Programa Perfeccionamiento de Doctores (to GS-D); Junta de Andalucía, Consejería de Conocimiento, Investigación y Universidades grant SOMM17/6107/UGR (to JRR) via the ERDF; Grant FJC2020-044453-I funded by MCIN/AEI/10.13039/501100011033 and by “European Union NextGenerationEU/PRTR” (to JMA); the Fundación Alfonso Martín Escudero (to GS-D); and a Marie Skłodowska-Curie Actions-Individual Fellowship grant (Horizon2020, 101028941, to GS-D).