Mostrar el registro sencillo del ítem

dc.creatorLópez Torres, Diegoes_ES
dc.creatorElosúa Aguado, Césares_ES
dc.creatorVillatoro, Joeles_ES
dc.creatorZubia, Josebaes_ES
dc.creatorRothhardt, Manfredes_ES
dc.creatorSchuster, Kayes_ES
dc.creatorArregui San Martín, Francisco Javieres_ES
dc.date.accessioned2024-01-15T11:39:42Z
dc.date.available2024-01-15T11:39:42Z
dc.date.issued2017
dc.identifier.citationLopez-Torres, D., Elosua, C., Villatoro, J., Zubia, J., Rothhardt, M., Schuster, K., & Arregui, F. J. (2017). Photonic crystal fiber interferometer coated with a PAH/PAA nanolayer as humidity sensor. Sensors and Actuators B: Chemical, 242, 1065-1072. https://doi.org/10.1016/j.snb.2016.09.144en
dc.identifier.issn0925-4005en
dc.identifier.urihttps://hdl.handle.net/2454/47050
dc.descriptionAlojado según Res. CNEAI 5/12/23es_ES
dc.description.abstractIn this paper, an optical fiber interferometric humidity sensor is presented. The device consists of 1 cmlong segment of photonic crystal fiber (PCF) spliced to standard single mode fibers (SMFs), forming an interferometer: the two collapsed interfaces between PCF and SMF segments produce the excitation and recombination of core and cladding modes. The latter interact with a poly(allylamine hydrochloride) (PAH) and poly(acrylic acid) (PAA) polymeric nanocoating deposited on the PCF by the well-established layer-by-layer nano assembly (LbL) technique. Humidity modifies the index of the polymeric nanolayer which in turns alters the cladding modes along the PCF segment and causes a detectable shift to the interference pattern. A study of different nanocoting thicknesses is presented in order to obtain the best possible sensibility for the sensor. Furthermore, the interrogation of the humidity sensor is presented not only by the conventional study of the spectrum shift amplitude, but also making use of the Fast Fourier Transform (FFT), which yields a linearization of the device response. The sensor here presented is reproducible, can resolve 0.074% of relative humidity (RH) and operates in the 20–95% RH range. Moreover, it exhibits response time of 0.3 s, a negligible cross sensitivity to temperature as well as long term stability.en
dc.description.sponsorshipThis work was supported by the Spanish Economy and Competitivity Ministry-FEDER TEC2013-43679-R.en
dc.format.mimetypeapplication/pdfen
dc.language.isoengen
dc.publisherElsevieren
dc.relation.ispartofSensors and Actuators B 242 (2017 ) 1065-1072en
dc.subjectPhotonic crystal fiberen
dc.subjectInterferometeren
dc.subjectLayer-by-layer nanoassemblyen
dc.subjectHumidity sensoren
dc.subjectFast Fourier transformen
dc.titlePhotonic crystal fiber interferometer coated with a PAH/PAA nanolayer as humidity sensoren
dc.typeArtículo / Artikuluaes
dc.typeinfo:eu-repo/semantics/articleen
dc.date.updated2024-01-15T11:32:12Z
dc.contributor.departmentIngeniería Eléctrica y Electrónicaes_ES
dc.contributor.departmentIngeniaritza Elektrikoa eta Elektronikoaeu
dc.contributor.departmentInstitute of Smart Cities - ISCen
dc.rights.accessRightsAcceso cerrado / Sarbide itxiaes
dc.rights.accessRightsinfo:eu-repo/semantics/closedAccessen
dc.identifier.doi10.1016/j.snb.2016.09.144
dc.relation.projectIDinfo:eu-repo/grantAgreement/MINECO//TEC2013-43679-R/ES/en
dc.relation.publisherversionhttps://doi.org/10.1016/j.snb.2016.09.144