López-Amo Sáinz, Manuel

Loading...
Profile Picture

Email Address

Birth Date

Job Title

Last Name

López-Amo Sáinz

First Name

Manuel

person.page.departamento

Ingeniería Eléctrica, Electrónica y de Comunicación

person.page.instituteName

ISC. Institute of Smart Cities

person.page.observainves

person.page.upna

Name

Search Results

Now showing 1 - 10 of 17
  • PublicationOpen Access
    Characterization of a hybrid Fabry-Pérot Cavity based on a four-bridge double-Y-shape-core microstructured fiber
    (SPIE, 2014-06-02) Rodrigues Pinto, Ana Margarida; López Aldaba, Aitor; López-Amo Sáinz, Manuel; Frazão, Orlando; Santos, José Luís; Baptista, José Manuel; Baierl, Hardy; Auguste, Jean-Louis; Jamier, Raphael; Roy, Philippe; Ingeniería Eléctrica y Electrónica; Ingeniaritza Elektrikoa eta Elektronikoa; Institute of Smart Cities - ISC
    In this work, a hybrid Fabry-Perot interferometer based on a novel four-bridge microstructured fiber is presented and characterized. The characterization of this cavity is performed in the L-band using two different instruments: an optical spectrum analyzer and an optical backscatter reflectometer. The Fabry-Perot output signal presents linear variation with temperature changes (sensitivity 9.8-11.9 pm/ºC), variation with the polarization states of light and high stability.
  • PublicationOpen Access
    Enhancement of the sensitivity of a volatile organic compounds MOF sensor by means of its structure
    (MDPI, 2019) López Torres, Diego; López Aldaba, Aitor; Elosúa Aguado, César; Auguste, Jean-Louis; Jamier, Raphael; Roy, Philippe; López-Amo Sáinz, Manuel; Arregui San Martín, Francisco Javier; Ingeniería Eléctrica y Electrónica; Ingeniaritza Elektrikoa eta Elektronikoa; Institute of Smart Cities - ISC; Universidad Pública de Navarra / Nafarroako Unibertsitate Publikoa
    In this paper, we experimentally compare several core structures of Microstructured Optical Fibers (MOFs) for low-finesse Fabry-Pérot (FP) sensors. These sensors are designed for Volatile Organic Compounds (VOCs) measurements. We deposit Indium Tin Oxide (ITO) thin films by sputtering on the MOFs and different optical phase responses of the FP were measured for saturated atmospheres of ethanol. The sensitivity of the developed sensors is demonstrated to depend on the geometry and the dimensions of the MOF-cores. The sensors show recovery times under 100 s and the baselines are fully recovered after exposure to VOC.
  • PublicationOpen Access
    Interferometric vs wavelength selective optical fiber sensors for cryogenic temperature measurements
    (SPIE, 2017) Miguel Soto, Verónica de; Leandro González, Daniel; López Aldaba, Aitor; Beato López, Juan Jesús; Pérez de Landazábal Berganzo, José Ignacio; Auguste, Jean-Louis; Jamier, Raphael; Roy, Philippe; López-Amo Sáinz, Manuel; Ingeniaritza Elektrikoa eta Elektronikoa; Fisika; Institute for Advanced Materials and Mathematics - INAMAT2; Ingeniería Eléctrica y Electrónica; Física
    In this work, a preliminary study of the behavior of two different interferometric fiber optic sensors and two different wavelength selective fiber optic sensors is performed. A photonic cristal fiber Fabry-Pérot interferometer, a Sagnac interferometer, a commercial fiber Bragg grating (FBG) and a π-phase shifted fiber Bragg grating interrogated in a random distributed feedback fiber laser are analyzed. A comparison of their sensitivities and resolutions is carried out to analyze their performance as sensors for cryogenic temperatures, taking into account their advantages and drawbacks.
  • PublicationOpen Access
    Microstructured optical fiber sensor for soil moisture measurements
    (Optical Society of America, 2018) López Aldaba, Aitor; López Torres, Diego; Campo-Bescós, Miguel; López Rodríguez, José Javier; Yerro Lizarazu, David; Elosúa Aguado, César; Arregui San Martín, Francisco Javier; Auguste, Jean-Louis; Jamier, Raphael; Roy, Philippe; López-Amo Sáinz, Manuel; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren; Ingeniaritza; Institute of Smart Cities - ISC; Ingeniería Eléctrica, Electrónica y de Comunicación; Ingeniería
    A discrete sensor based on a Sn0₂-FP (Fabry-Pérot) cavity is presented and characterized in real soil conditions. Results are compared, for the first time to our knowledge, with a commercial capacitive sensor and gravimetric measurements.
  • PublicationOpen Access
    SnO2-MOF-Fabry-Perot optical sensor for relative humidity measurements
    (Elsevier, 2018) López Aldaba, Aitor; López Torres, Diego; Elosúa Aguado, César; Auguste, Jean-Louis; Jamier, Raphael; Roy, Philippe; Arregui San Martín, Francisco Javier; López-Amo Sáinz, Manuel; Ingeniaritza Elektrikoa eta Elektronikoa; Institute of Smart Cities - ISC; Ingeniería Eléctrica y Electrónica
    In this paper, a new optical fiber sensor for relative humidity measurements is presented and characterized. The sensor is based on a SnO2 sputtering deposition on a microstructured optical fiber (MOF) low-finesse Fabry-Pérot (FP) sensing head. The feasibility of the device as a breathing sensor is also experimentally demonstrated. The interrogation of the sensing head is carried out by monitoring the Fast Fourier Transform phase variations of the FP interference frequency. This method substitutes the necessity of tracking the optical spectrum peaks or valleys, which can be a handicap when noise or multiple contributions are present: therefore, it is low-sensitive to noise and to artifacts signal amplitude. The sensor shows a linear behavior in a wide relative humidity range (20%–90% relative humidity) in which the sensitivity is 0.14 rad/%; the maximum observed instability is 0.007 rad, whereas the highest hysteresis is 5% RH. The cross correlation with temperature is also considered and a method to lower its influence is proposed. For human breathing measurement, the registered rising and recovery times are 370 ms and 380 ms respectively.
  • PublicationOpen Access
    Study of optical fiber sensors for cryogenic temperature measurements
    (MDPI, 2017) Miguel Soto, Verónica de; Leandro González, Daniel; López Aldaba, Aitor; Beato López, Juan Jesús; Pérez de Landazábal Berganzo, José Ignacio; Auguste, Jean-Louis; Jamier, Raphael; Roy, Philippe; López-Amo Sáinz, Manuel; Ingeniaritza Elektrikoa eta Elektronikoa; Fisika; Institute for Advanced Materials and Mathematics - INAMAT2; Institute of Smart Cities - ISC; Ingeniería Eléctrica y Electrónica; Física; Universidad Pública de Navarra / Nafarroako Unibertsitate Publikoa
    In this work, the performance of five different fiber optic sensors at cryogenic temperatures has been analyzed. A photonic crystal fiber Fabry-Pérot interferometer, two Sagnac interferometers, a commercial fiber Bragg grating (FBG), and a -phase shifted fiber Bragg grating interrogated in In this work, the performance of five different fiber optic sensors at cryogenic temperatures has been analyzed. A photonic crystal fiber Fabry-Pérot interferometer, two Sagnac interferometers, a commercial fiber Bragg grating (FBG), and a π-phase shifted fiber Bragg grating interrogated in a random distributed feedback fiber laser have been studied. Their sensitivities and resolutions as sensors for cryogenic temperatures have been compared regarding their advantages and disadvantages. Additionally, the results have been compared with the given by a commercial optical backscatter reflectometer that allowed for distributed temperature measurements of a single mode fiber.
  • PublicationOpen Access
    Title enhancement of the sensitivity of a volatile organic compounds MOF-sensor by means of its structure
    (MDPI, 2017) López Torres, Diego; López Aldaba, Aitor; Elosúa Aguado, César; Auguste, Jean-Louis; Jamier, Raphael; Roy, Philippe; López-Amo Sáinz, Manuel; Arregui San Martín, Francisco Javier; Ingeniaritza Elektrikoa eta Elektronikoa; Institute for Advanced Materials and Mathematics - INAMAT2; Ingeniería Eléctrica y Electrónica; Universidad Pública de Navarra / Nafarroako Unibertsitate Publikoa
    In this paper, we experimentally compare several core structures of Microstructured Optical Fibers (MOFs) for low-finesse Fabry-Pérot (FP) sensors. These sensors are designed for Volatile Organic Compounds (VOCs) measurements. We deposit Indium Tin Oxide (ITO) thin films by sputtering on the MOFs and different optical phase responses of the FP were measured for saturated atmospheres of ethanol. The sensitivity of the developed sensors is demonstrated to depend on the geometry and the dimensions of the MOF-cores. The sensors show recovery times under 100 s and the baselines are fully recovered after exposure to VOC.
  • PublicationOpen Access
    Relative humidity multi-point optical sensors system based on Fast Fourier multiplexing technique
    (SPIE, 2017) López Aldaba, Aitor; López Torres, Diego; Elosúa Aguado, César; Auguste, Jean-Louis; Jamier, Raphael; Roy, Philippe; Arregui San Martín, Francisco Javier; López-Amo Sáinz, Manuel; Ingeniaritza Elektrikoa eta Elektronikoa; Institute of Smart Cities - ISC; Ingeniería Eléctrica y Electrónica
    In this paper, a new multipoint optical fiber system for relative humidity measurements based on Sn02-FP (Fabry-Pérot) sensing heads and an optical interrogator as single active device is presented and characterized. The interrogation of the sensing heads is carried out by monitoring the Fast Fourier Transform phase variations of the FP (Fabry-Pérot) interference frequencies. This method allows to multiplex several sensors with different wavelength spacing interference pattern. The sensors operate within a wide humidity range (20%-90% relative humidity) with low crosstalk between them. Five sensing heads have been measured using two different channels of the optical interrogator. The availability of four channels in the interrogator allows to multiplex a higher number of sensors, reducing proportionally the cost of each sensing point.
  • PublicationOpen Access
    Experimental and numerical characterization of a hybrid Fabry-Perot cavity for temperature sensing
    (MDPI, 2015) López Aldaba, Aitor; Rodrigues Pinto, Ana Margarida; López-Amo Sáinz, Manuel; Frazão, Orlando; Santos, José Luís; Baptista, José Manuel; Baierl, Hardy; Auguste, Jean-Louis; Jamier, Raphael; Roy, Philippe; Ingeniería Eléctrica y Electrónica; Ingeniaritza Elektrikoa eta Elektronikoa
    A hybrid Fabry-Pérot cavity sensing head based on a four-bridge microstructured fiber is characterized for temperature sensing. The characterization of this cavity is performed numerically and experimentally in the L-band. The sensing head output signal presents a linear variation with temperature changes, showing a sensitivity of 12.5 pm/°C. Moreover, this Fabry-Pérot cavity exhibits good sensitivity to polarization changes and high stability over time.
  • PublicationOpen Access
    SnO2-MOF-Fabry-Pérot humidity optical sensor system based on Fast Fourier transform technique
    (SPIE, 2016) López Aldaba, Aitor; López Torres, Diego; Ascorbe Muruzabal, Joaquín; Rota Rodrigo, Sergio; Elosúa Aguado, César; López-Amo Sáinz, Manuel; Arregui San Martín, Francisco Javier; Corres Sanz, Jesús María; Auguste, Jean-Louis; Jamier, Raphael; Roy, Philippe; Ingeniaritza Elektrikoa eta Elektronikoa; Institute of Smart Cities - ISC; Ingeniería Eléctrica y Electrónica
    In this paper, a new sensor system for relative humidity measurements based on a SnO2 sputtering deposition on a microstructured optical fiber (MOF) low-finesse Fabry-Pérot (FP) sensing head is presented and characterized. The interrogation of the sensing head is carried out by monitoring the Fast Fourier Transform phase variations of the FP interference frequency. This method is low-sensitive to signal amplitude variations and also avoids the necessity of tracking the evolution of peaks and valleys in the spectrum. The sensor is operated within a wide humidity range (20%-90% relative humidity) with a maximum sensitivity achieved of 0.14rad/%. The measurement method uses a commercial optical interrogator as the only active element, this compact solution allows real time analysis of the data.