Person:
Corres Sanz, Jesús María

Loading...
Profile Picture

Email Address

Birth Date

Research Projects

Organizational Units

Job Title

Last Name

Corres Sanz

First Name

Jesús María

person.page.departamento

ORCID

0000-0003-1298-5700

person.page.upna

1876

Name

Search Results

Now showing 1 - 9 of 9
  • PublicationOpen Access
    High sensitivity humidity sensor based on cladding-etched optical fiber and lossy mode resonances
    (Elsevier, 2016) Ascorbe Muruzabal, Joaquín; Corres Sanz, Jesús María; Matías Maestro, Ignacio; Arregui San Martín, Francisco Javier; Institute of Smart Cities - ISC; Universidad Pública de Navarra / Nafarroako Unibertsitate Publikoa
    In this work a high sensitivity optical fiber humidity sensor (OFHS) is presented. The configuration chosen for this purpose is a cladding-etched single mode optical fiber (CE-SMF) coated with a thin film of tin oxide (SnO2). The etching has been made using hydrofluoric acid (HF) and the coating has been fabricated by means of sputtering. Tin oxide was used to build the nano-coating which produces the Lossy Mode Resonance (LMR) and works as sensitive material. Theoretical and experimental results are shown and compared. The device was tested using a climatic chamber in order to obtain the response of the OFHS to relative humidity. Changes greater than 130 nm have been obtained for relative humidity varying from 20% to 90%, which gives a sensitivity of 1.9 nm/%RH.
  • PublicationOpen Access
    Route towards a label-free optical waveguide sensing platform based on lossy mode resonances
    (IFSA Publishing, 2019) Ruiz Zamarreño, Carlos; Zubiate Orzanco, Pablo; Ozcariz Celaya, Aritz; Elosúa Aguado, César; Socorro Leránoz, Abián Bentor; Urrutia Azcona, Aitor; López Torres, Diego; Acha Morrás, Nerea de; Ascorbe Muruzabal, Joaquín; Vitoria Pascual, Ignacio; Imas González, José Javier; Corres Sanz, Jesús María; Díaz Lucas, Silvia; Hernáez Sáenz de Zaitigui, Miguel; Goicoechea Fernández, Javier; Arregui San Martín, Francisco Javier; Matías Maestro, Ignacio; Del Villar, Ignacio; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren; Institute of Smart Cities - ISC; Ingeniería Eléctrica, Electrónica y de Comunicación; Gobierno de Navarra / Nafarroako Gobernua,0011-1365-2017- 000117; Universidad Pública de Navarra / Nafarroako Unibertsitate Publikoa, PJUPNA26
    According to recent market studies of the North American company Allied Market Research, the field of photonic sensors is an emerging strategic field for the following years and it is expected to garner $18 billion by 2021. The integration of micro and nanofabrication technologies in the field of sensors has allowed the development of new technological concepts such as lab-on-a-chip which have achieved extraordinary advances in terms of detection and applicability, for example in the field of biosensors. This continuous development has allowed that equipment consisting of many complex devices that occupied a whole room a few years ago, at present it is possible to handle them in the palm of the hand; that formerly long duration processes are carried out in a matter of milliseconds and that a technology previously dedicated solely to military or scientific uses is available to the vast majority of consumers. The adequate combination of micro and nanostructured coatings with optical fiber sensors has permitted us to develop novel sensing technologies, such as the first experimental demonstration of lossy mode resonances (LMRs) for sensing applications, with more than one hundred citations and related publications in high rank journals and top conferences. In fact, fiber optic LMR-based devices have been proven as devices with one of the highest sensitivity for refractometric applications. Refractive index sensitivity is an indirect and simple indicator of how sensitive the device is to chemical and biological species, topic where this proposal is focused. Consequently, the utilization of these devices for chemical and biosensing applications is a clear opportunity that could open novel and interesting research lines and applications as well as simplify current analytical methodologies. As a result, on the basis of our previous experience with LMR based sensors to attain very high sensitivities, the objective of this paper is presenting the route for the development of label-free optical waveguide sensing platform based on LMRs that enable to explore the limits of this technology for bio-chemosensing applications.
  • PublicationOpen Access
    Fiber-optic immunosensor based on lossy mode resonances induced by indium tin oxide thin-films
    (IEEE, 2017) Socorro Leránoz, Abián Bentor; Del Villar, Ignacio; Corres Sanz, Jesús María; Arregui San Martín, Francisco Javier; Matías Maestro, Ignacio; Ingeniería Eléctrica y Electrónica; Ingeniaritza Elektrikoa eta Elektronikoa; Institute of Smart Cities - ISC
    A novel immunosensor based on lossy mode resonances (LMRs) induced in optical fibers is developed in this contribution. Indium tin oxide (ITO) is sputtered on the optical substrate to generate an LMR in the transmission spectrum. Type G immunoglobulins (IgGs) are then attached to the ITO-coated fiber using (3-glycidyloxypropyl)trimethoxysilane (GPTMS). A phosphate buffer saline solution containing anti-IgGs is used to detect the biological reactions. The presented device is capable of detecting anti-IgG concentrations up to 10 nM. These results will permit the fabrication of biosensors based on a covalent attachment of bioreceptors over an LMR inducing thin-film.
  • PublicationOpen Access
    Tapered single-mode optical fiber pH sensor based on lossy mode resonances generated by a polymeric thin-film
    (IEEE, 2012) Socorro Leránoz, Abián Bentor; Del Villar, Ignacio; Corres Sanz, Jesús María; Arregui San Martín, Francisco Javier; Matías Maestro, Ignacio; Ingeniería Eléctrica y Electrónica; Ingeniaritza Elektrikoa eta Elektronikoa; Universidad Pública de Navarra / Nafarroako Unibertsitate Publikoa
    Lossy mode resonances can be generated with certain polymeric nanostructures, such as those obtained with a multilayered assembly of poly(allylamine hydrochloride) and poly (acrylic acid). This coating is adsorbed by the electrostatic self assembly technique onto a tapered single-mode optical fiber, in order to evaluate its performance when detecting pH. According to the results reported in this work, the high sensitivity given by a tapering process in a single-mode optical fiber is increased by the effect of this kind of electromagnetic resonances. Particularly, in a pH range from 4.0 to 6.0 the overall wavelength shift of this sensor reaches 200 nm and the transmission at the resonance wavelengths can fall down to -50 dB. These data provide results which can be taken into account to detect pH with high accuracy.
  • PublicationOpen Access
    Recent developments in fiber optics humidity sensors
    (MDPI, 2017) Ascorbe Muruzabal, Joaquín; Corres Sanz, Jesús María; Arregui San Martín, Francisco Javier; Matías Maestro, Ignacio; Ingeniaritza Elektrikoa eta Elektronikoa; Institute of Smart Cities - ISC; Ingeniería Eléctrica y Electrónica; Universidad Pública de Navarra / Nafarroako Unibertsitate Publikoa
    A wide range of applications such as health, human comfort, agriculture, food processing and storage, and electronic manufacturing, among others, require fast and accurate measurement of humidity. Sensors based on optical fibers present several advantages over electronic sensors and great research efforts have been made in recent years in this field. The present paper reports the current trends of optical fiber humidity sensors. The evolution of optical structures developed towards humidity sensing, as well as the novel materials used for this purpose, will be analyzed. Well-known optical structures, such as long-period fiber gratings or fiber Bragg gratings, are still being studied towards an enhancement of their sensitivity. Sensors based on lossy mode resonances constitute a platform that combines high sensitivity with low complexity, both in terms of their fabrication process and the equipment required. Novel structures, such as resonators, are being studied in order to improve the resolution of humidity sensors. Moreover, recent research on polymer optical fibers suggests that the sensitivity of this kind of sensor has not yet reached its limit. Therefore, there is still room for improvement in terms of sensitivity and resolution.
  • PublicationOpen Access
    Influence of waist length in lossy mode resonances generated with coated tapered single mode optical fibers
    (IEEE, 2011) Socorro Leránoz, Abián Bentor; Del Villar, Ignacio; Corres Sanz, Jesús María; Arregui San Martín, Francisco Javier; Matías Maestro, Ignacio; Ingeniería Eléctrica y Electrónica; Ingeniaritza Elektrikoa eta Elektronikoa; Universidad Pública de Navarra / Nafarroako Unibertsitate Publikoa
    In this work, the generation of electromagnetic resonances due to the deposition of a nanocoating on a tapered single-mode optical fiber is analyzed. The layer-by-layer technique is used to control the thickness of the nanocoating. According to the results that have been obtained, the depth of the resonance depends on the length of the waist region. Variations in the transmitted optical power of 40 dB are observed in just a few layers. This can be considered in the fabrication of both highly sensitive resonance-based sensors and optical filters.
  • PublicationOpen Access
    A comparative study between SMS interferometers and lossy mode resonace optical fiber devices for sensing applications
    (SPIE, 2015) Socorro Leránoz, Abián Bentor; Hernáez Sáenz de Zaitigui, Miguel; Del Villar, Ignacio; Corres Sanz, Jesús María; Arregui San Martín, Francisco Javier; Matías Maestro, Ignacio; Ingeniería Eléctrica y Electrónica; Ingeniaritza Elektrikoa eta Elektronikoa; Universidad Pública de Navarra / Nafarroako Unibertsitate Publikoa; Universidad Pública de Navarra / Nafaroako Unibertsitate Publikoa
    Optical fiber sensors are of great interest due to their intrinsic advantages over electronic sensors. In this work, the sensing characteristics of two different and novel optical fiber devices are compared, after simultaneously depositing a thin-film using the layer-by-layer assembly deposition process. The first one is an SMS structure, formed by splicing two single-mode fiber pigtails on both sides of a coreless multimode fiber segment. This structure induces an interferometric phenomenon that generates several attenuation and transmission bands along the spectrum. These bands are sensitive to variations in the surrounding refractive index, although this sensitivity has been enhanced by a TiO2/PSS thin-film. The other device is a 40 mm uncladded segment of a 200 µm-core multimode optical fiber. When coated by a TiO2/PSS thinfilm, part of the light transmitted into the uncladded core is coupled into the thin-film, generating a lossy mode resonance (LMR). The absorption peaks due to these phenomena red-shift as long as the thin-film thickness increases or the external RI becomes higher. The performance of these devices as refractometers and relative humidity sensors are tested. Results show that the LMR-based sensor is more sensitive in both situations, in spite of its lower sensitivity. Particularly, it presents a 7-fold sensitivity enhancement when measuring surrounding medium refractive index changes and a 10-fold sensitivity enhancement when measuring environmental relative humidity. To our knowledge, this is the first time that a comparative study between SMS and LMR sensors is performed.
  • PublicationOpen Access
    AC/DC millivoltage sensor by means of ITO-coated optical fibers: towards monitoring of biosignals
    (IEEE, 2019) Aginaga Etxamendi, Concepción Isabel; Socorro Leránoz, Abián Bentor; Fuentes Lorenzo, Omar; Del Villar, Ignacio; Corres Sanz, Jesús María; Matías Maestro, Ignacio; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren; Institute of Smart Cities - ISC; Ingeniería Eléctrica, Electrónica y de Comunicación; Gobierno de Navarra / Nafarroako Gobernua
    This contribution shows the monitoring of AC and DC millivoltage signals by means of lossy mode resonances generated by Indium Tin Oxide (ITO) on optical fibers. Sensors were obtained by sputtering ITO thin-films onto 25 mm-length segments of 200 μm bare optical fibers. Depositing a 1 μm thin-film of ITO leads to obtain reduced thin-film resistances of near 340 ohms. This allows the detection of voltage signals by monitoring the wavelength shift of the resonances. Sensitivities up to 40 nm/V can be achieved when tracking sinusoidal signals of a few cents of mV peak-to-peak. This opens the path for further research pursuing the detection of biomedical signals.
  • PublicationOpen Access
    Wavelength and intensity based lossy mode resonance breathing sensor
    (Elsevier, 2021) Bohórquez Navarro, Dina Luz; Del Villar, Ignacio; Corres Sanz, Jesús María; Matías Maestro, Ignacio; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren; Institute of Smart Cities - ISC; Ingeniería Eléctrica, Electrónica y de Comunicación; Universidad Pública de Navarra / Nafarroako Unibertsitate Publikoa
    Copper oxide (CuO) allows the generation of lossy mode resonance (LMR) in a wide wavelength range of the optical spectrum, both in the visible and the near-infrared (NIR). For this, it is necessary to use a configuration based on the lateral incidence of light on the edge of a planar waveguide structure. On the other hand, the use of additional coatings of tin oxide (SnO2) and agarose allows an increase in the sensitivity of the sensor, in response to the breathing monitoring. The sensors were characterized, both in intensity and wavelength. In both cases their behavior depends on the position of the LMR in the optical spectrum. Therefore, it is convenient to extract the design rules that allow an optimal behavior of the sensor. In this sense, sensors located in the NIR presented a better behavior in terms of sensitivity and quality of the signal. In addition, the devices were tested in different conditions: repetitive tests at different distances, oral and nasal breathing, and breathing after doing physical exercise.