Person: Rodríguez Falces, Javier
Loading...
Email Address
person.page.identifierURI
Birth Date
Research Projects
Organizational Units
Job Title
Last Name
Rodríguez Falces
First Name
Javier
person.page.departamento
Ingeniería Eléctrica, Electrónica y de Comunicación
person.page.instituteName
ISC. Institute of Smart Cities
ORCID
0000-0002-9150-8955
person.page.upna
8624
Name
16 results
Search Results
Now showing 1 - 10 of 16
Publication Open Access A new muscle architecture model with non-uniform distribution of muscle fiber types(World Academy of Science, Engineering and Technology, 2007) Navallas Irujo, Javier; Malanda Trigueros, Armando; Gila Useros, Luis; Rodríguez Falces, Javier; Rodríguez Carreño, Ignacio; Ingeniería Eléctrica y Electrónica; Ingeniaritza Elektrikoa eta ElektronikoaAccording to previous studies, some muscles present a non-homogeneous spatial distribution of its muscle fiber types and motor unit types. However, available muscle models only deal with muscles with homogeneous distributions. In this paper, a new architecture muscle model is proposed to permit the construction of non-uniform distributions of muscle fibers within the muscle cross section. The idea behind is the use of a motor unit placement algorithm that controls the spatial overlapping of the motor unit territories of each motor unit type. Results show the capabilities of the new algorithm to reproduce arbitrary muscle fiber type distributions.Publication Open Access Modelling fibrillation potentials: analysis of time parameters in the muscle intracellular action potential(IEEE, 2007) Rodríguez Falces, Javier; Malanda Trigueros, Armando; Gila Useros, Luis; Rodríguez Carreño, Ignacio; Navallas Irujo, Javier; Ingeniería Eléctrica y Electrónica; Ingeniaritza Elektrikoa eta ElektronikoaA single fibre action potential (SFAP) can be modelled as the convolution of a biolectrical source and a filter impulse response. In the Dimitrov-Dimitrova (D-D) convolutional model, the first temporal derivative of the intracellular action potential (IAP) is used as the source, and T spl is a time parameter related to the duration of the IAP waveform. Our work is centred on the relation between Tspl and the main spike duration (MSD), defined as the time interval between the first and third phases of the SFAP. We show that Tspl essentially determines the MSD parameter. As experimental data, we used fibrillation potentials (FPs) of two different muscles to study the D-D model. We found that T spl should have a certain statistical variability in order to explain the variability in the MSD of our FPs. In addition, we present a method to estimate the T spl values corresponding to a given SFAP from its measured MSD.Publication Open Access A masked least-squares smoothing procedure for artifact reduction in scanning-EMG recordings(Springer, 2018) Corera Orzanco, Íñigo; Eciolaza Ferrando, Adrián; Rubio Zamora, Oliver; Malanda Trigueros, Armando; Rodríguez Falces, Javier; Navallas Irujo, Javier; Ingeniería Eléctrica, Electrónica y de Comunicación; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio IngeniaritzarenScanning-EMG is an electrophysiological technique in which the electrical activity of the motor unit is recorded at multiple points along a corridor crossing the motor unit territory. Correct analysis of the scanning-EMG signal requires prior elimination of interference from nearby motor units. Although the traditional processing based on the median filtering is effective in removing such interference, it distorts the physiological waveform of the scanning-EMG signal. In this study, we describe a new scanning-EMG signal processing algorithm that preserves the physiological signal waveform while effectively removing interference from other motor units. To obtain a cleaned-up version of the scanning signal, the masked least-squares smoothing (MLSS) algorithm recalculates and replaces each sample value of the signal using a least-squares smoothing in the spatial dimension, taking into account the information of only those samples that are not contaminated with activity of other motor units. The performance of the new algorithm with simulated scanning-EMG signals is studied and compared with the performance of the median algorithm and tested with real scanning signals. Results show that the MLSS algorithm distorts the waveform of the scanning-EMG signal much less than the median algorithm (approximately 3.5 dB gain), being at the same time very effective at removing interference components.Publication Open Access Motor unit profile: a new way to describe the scanning-EMG potential(Elsevier, 2017) Corera Orzanco, Íñigo; Malanda Trigueros, Armando; Rodríguez Falces, Javier; Porta Cuéllar, Sonia; Navallas Irujo, Javier; Ingeniería Eléctrica y Electrónica; Ingeniaritza Elektrikoa eta ElektronikoaThe motor unit profile, a representation of the trajectories of positive and negative turns of a scanning-EMG signal, is a new way to characterize the motor unit potential. Such characterization allows quantification of the scanning-EMG signal's complexity, which is closely related to the anatomy and physiology of the motor unit. To extract the motor unit profile, an algorithm that detects the turns of the scanning-EMG signal and links them using point-tracking techniques has been developed. The performance of this algorithm is sensitive to three parameters: the turn detection threshold, the maximum tracking interval threshold, and the trajectory purge threshold. Real scanning-EMG signals have been used to analyze the algorithm's behavior and the influence of the algorithm's parameters and to determine which parameter values provide the best performance.Publication Open Access EMG probability density function: a new way to look at EMG signal filling from single motor unit potential to full interference pattern(IEEE, 2023) Navallas Irujo, Javier; Eciolaza Ferrando, Adrián; Mariscal Aguilar, Cristina; Malanda Trigueros, Armando; Rodríguez Falces, Javier; Ingeniería Eléctrica, Electrónica y de Comunicación; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio IngeniaritzarenAn analytical derivation of the EMG signal's amplitude probability density function (EMG PDF) is presented and used to study how an EMG signal builds-up, or fills, as the degree of muscle contraction increases. The EMG PDF is found to change from a semi-degenerate distribution to a Laplacian-like distribution and finally to a Gaussian-like distribution. We present a measure, the EMG filling factor, to quantify the degree to which an EMG signal has been built-up. This factor is calculated from the ratio of two non-central moments of the rectified EMG signal. The curve of the EMG filling factor as a function of the mean rectified amplitude shows a progressive and mostly linear increase during early recruitment, and saturation is observed when the EMG signal distribution becomes approximately Gaussian. Having presented the analytical tools used to derive the EMG PDF, we demonstrate the usefulness of the EMG filling factor and curve in studies with both simulated signals and real signals obtained from the tibialis anterior muscle of 10 subjects. Both simulated and real EMG filling curves start within the 0.2 to 0.35 range and rapidly rise towards 0.5 (Laplacian) before stabilizing at around 0.637 (Gaussian). Filling curves for the real signals consistently followed this pattern (100% repeatability within trials in 100% of the subjects). The theory of EMG signal filling derived in this work provides (a) an analytically consistent derivation of the EMG PDF as a function of motor unit potentials and motor unit firing patterns; (b) an explanation of the change in the EMG PDF according to degree of muscle contraction; and (c) a way (the EMG filling factor) to quantify the degree to which an EMG signal has been built-up.Publication Open Access Motor unit action potential duration, II: a new automatic measurement method based on the wavelet transform(Lippincott, Williams & Wilkins, 2007) Rodríguez Carreño, Ignacio; Gila Useros, Luis; Malanda Trigueros, Armando; García Gurtubay, Ignacio; Mallor Giménez, Fermín; Gómez Elvira, Sagrario; Rodríguez Falces, Javier; Navallas Irujo, Javier; Ingeniería Eléctrica y Electrónica; Estadística e Investigación Operativa; Ingeniaritza Elektrikoa eta Elektronikoa; Estatistika eta Ikerketa OperatiboaTo present and evaluate a new algorithm, based on the wavelet transform, for the automatic measurement of motor unit action potential (MUAP) duration. A total of 240 MUAPs were studied. The waveform of each MUAP was wavelet-transformed, and the start and end points were estimated by regarding the maxima and minima points in a particular scale of the wavelet transform. The results of the new method were compared with the gold standard of duration marker positions obtained by manual measurement. The new method was also compared with a conventional algorithm, which we had found to be best in a previous comparative study. To evaluate the new method against manual measurements, the dispersion of automatic and manual duration markers were analyzed in a set of 19 repeatedly recorded MUAPs. The differences between the new algorithm’s marker positions and the gold standard of duration marker positions were smaller than those observed with the conventional method. The dispersion of the new algorithm’s marker positions was slightly less than that of the manual one. Our new method for automatic measurement of MUAP duration is more accurate than other available algorithms and more consistent than manual measurements.Publication Open Access M-wave changes caused by brief voluntary and stimulated isometric contractions(Springer, 2023) Rodríguez Falces, Javier; Malanda Trigueros, Armando; Navallas Irujo, Javier; Place, Nicolas; Ingeniería Eléctrica, Electrónica y de Comunicación; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren; Universidad Pública de Navarra / Nafarroako Unibertsitate PublikoaIntroduction Under isometric conditions, the increase in muscle force is accompanied by a reduction in the fbers’ length. The efects of muscle shortening on the compound muscle action potential (M wave) have so far been investigated only by computer simulation. This study was undertaken to assess experimentally the M-wave changes caused by brief voluntary and stimulated isometric contractions. Methods Two diferent methods of inducing muscle shortening under isometric condition were adopted: (1) applying a brief (1 s) tetanic contraction and (2) performing brief voluntary contractions of diferent intensities. In both methods, supramaximal stimulation was applied to the brachial plexus and femoral nerves to evoke M waves. In the frst method, electrical stimulation (20 Hz) was delivered with the muscle at rest, whereas in the second, stimulation was applied while participants performed 5-s stepwise isometric contractions at 10, 20, 30, 40, 50, 60, 70, and 100% MVC. The amplitude and duration of the frst and second M-wave phases were computed. Results The main fndings were: (1) on application of tetanic stimulation, the amplitude of the M-wave frst phase decreased (~10%, P<0.05), that of the second phase increased (~50%, P<0.05), and the M-wave duration decreased (~20%, P<0.05) across the frst fve M waves of the tetanic train and then plateaued for the subsequent responses; (2) when superimposing a single electrical stimulus on muscle contractions of increasing forces, the amplitude of the M-wave frst phase decreased (~20%, P<0.05), that of the second phase increased (~30%, P<0.05), and M-wave duration decreased (~30%, P<0.05) as force was raised from 0 to 60–70% MVC force. Conclusions The present results will help to identify the adjustments in the M-wave profle caused by muscle shortening and also contribute to diferentiate these adjustments from those caused by muscle fatigue and/or changes in Na+–K+ pump activity.Publication Open Access Understanding EMG PDF changes with motor unit potential amplitudes, firing rates, and noise level through EMG filling curve analysis(IEEE, 2024-08-30) Navallas Irujo, Javier; Mariscal Aguilar, Cristina; Malanda Trigueros, Armando; Rodríguez Falces, Javier; Ingeniería Eléctrica, Electrónica y de Comunicación; Ingeniaritza Elektrikoa, Elektronikoa eta Telekomunikazio IngeniaritzaEMG filling curve characterizes the EMG filling process and EMG probability density function (PDF) shape change for the entire force range of a muscle.We aim to understand the relation between the physiological and recording variables, and the resulting EMG filling curves. We thereby present an analytical and simulation study to explain how the filling curve patterns relate to specific changes in the motor unit potential (MUP) waveforms and motor unit (MU) firing rates, the two main factors affecting the EMG PDF, but also to recording conditions in terms of noise level. We compare the analytical results with simulated cases verifying a perfect agreement with the analytical model. Finally, we present a set of real EMG filling curves with distinct patterns to explain the information about MUP amplitudes, MU firing rates, and noise level that these patterns provide in the light of the analytical study. Our findings reflect that the filling factor increases when firing rate increases or when newly recruited motor unit have potentials of smaller or equal amplitude than the former ones. On the other hand, the filling factor decreases when newly recruited potentials are larger in amplitude than the previous potentials. Filling curves are shown to be consistent under changes of the MUP waveform, and stretched under MUP amplitude scaling. Our findings also show how additive noise affects the filling curve and can even impede to obtain reliable information from the EMG PDF statistics.Publication Open Access Masked least-squares averaging in processing of scanning-EMG recordings with multiple-discharges(Springer, 2020) Corera Orzanco, Íñigo; Malanda Trigueros, Armando; Rodríguez Falces, Javier; Navallas Irujo, Javier; Ingeniería Eléctrica y Electrónica; Ingeniaritza Elektrikoa eta ElektronikoaRemoving artifacts from nearby motor units is one of the main objectives when processing scanning-EMG recordings. Methods such as median filtering or masked least-squares smoothing (MLSS) can be used to eliminate artifacts in recordings with just one discharge of the motor unit potential (MUP) at each location. However, more effective artifact removal can be achieved if several discharges per position are recorded. In this case, processing usually involves averaging the discharges available at each position and then applying a median filter in the spatial dimension. The main drawback of this approach is that the median filter tends to distort the signal waveform. In this paper, we present a new algorithm that operates on multiple discharges simultaneously and in the spatial dimension. We refer to this algorithm as the multi masked least-squares smoothing (MMLSS) algorithm: an extension of the MLSS algorithm for the case of multiple discharges. The algorithm is tested using simulated scanning-EMG signals in different recording conditions, i.e., at different levels of muscle contraction and for different numbers of discharges per position. Results demonstrate that the algorithm eliminates artifacts more effectively than any previously available method and does so without distorting the waveform of the signal.Publication Open Access Validation of the filling factor index to study the filling process of the sEMG signal in the quadriceps(Elsevier, 2023) Rodríguez Falces, Javier; Malanda Trigueros, Armando; Mariscal Aguilar, Cristina; Niazi, Imran Khan; Navallas Irujo, Javier; Ingeniería Eléctrica, Electrónica y de Comunicación; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio IngeniaritzarenIntroduction: The EMG filling factor is an index to quantify the degree to which an EMG signal has been filled. Here, we tested the validity of such index to analyse the EMG filling process as contraction force was slowly increased. Methods: Surface EMG signals were recorded from the quadriceps muscles of healthy subjects as force was gradually increased from 0 to 40% MVC. The sEMG filling process was analyzed by measuring the EMG filling factor (calculated from the non-central moments of the rectified sEMG). Results: (1) As force was gradually increased, one or two prominent abrupt jumps in sEMG amplitude appeared between 0 and 10% of MVC force in all the vastus lateralis and medialis. (2) The jumps in amplitude were originated when a few large-amplitude MUPs, clearly standing out from previous activity, appeared in the sEMG signal. (3) Every time an abrupt jump in sEMG amplitude occurred, a new stage of sEMG filling was initiated. (4) The sEMG was almost completely filled at 2–12% MVC. (5) The filling factor decreased significantly upon the occurrence of an sEMG amplitude jump, and increased as additional MUPs were added to the sEMG signal. (6) The filling factor curve was highly repeatable across repetitions. Conclusions: It has been validated that the filling factor is a useful, reliable tool to analyse the sEMG filling process. As force was gradually increased in the vastus muscles, the sEMG filling process occurred in one or two stages due to the presence of abrupt jumps in sEMG amplitude.