Matías Maestro, Ignacio

Loading...
Profile Picture

Email Address

Birth Date

Job Title

Last Name

Matías Maestro

First Name

Ignacio

person.page.departamento

Ingeniería Eléctrica, Electrónica y de Comunicación

person.page.instituteName

ISC. Institute of Smart Cities

person.page.observainves

person.page.upna

Name

Search Results

Now showing 1 - 10 of 66
  • PublicationOpen Access
    Single-mode-multimode-single-mode and lossy mode resonance-based devices: a comparative study for sensing applications
    (Springer-Verlag, 2015) Matías Maestro, Ignacio; Arregui San Martín, Francisco Javier; Corres Sanz, Jesús María; Del Villar, Ignacio; Hernáez Sáenz de Zaitigui, Miguel; Socorro Leránoz, Abián Bentor; Ingeniería Eléctrica y Electrónica; Ingeniaritza Elektrikoa eta Elektronikoa; Institute of Smart Cities - ISC
  • PublicationOpen Access
    Tapered single-mode optical fiber pH sensor based on lossy mode resonances generated by a polymeric thin-film
    (IEEE, 2012) Socorro Leránoz, Abián Bentor; Del Villar, Ignacio; Corres Sanz, Jesús María; Arregui San Martín, Francisco Javier; Matías Maestro, Ignacio; Ingeniería Eléctrica y Electrónica; Ingeniaritza Elektrikoa eta Elektronikoa; Universidad Pública de Navarra / Nafarroako Unibertsitate Publikoa
    Lossy mode resonances can be generated with certain polymeric nanostructures, such as those obtained with a multilayered assembly of poly(allylamine hydrochloride) and poly (acrylic acid). This coating is adsorbed by the electrostatic self assembly technique onto a tapered single-mode optical fiber, in order to evaluate its performance when detecting pH. According to the results reported in this work, the high sensitivity given by a tapering process in a single-mode optical fiber is increased by the effect of this kind of electromagnetic resonances. Particularly, in a pH range from 4.0 to 6.0 the overall wavelength shift of this sensor reaches 200 nm and the transmission at the resonance wavelengths can fall down to -50 dB. These data provide results which can be taken into account to detect pH with high accuracy.
  • PublicationOpen Access
    SnO2 based optical fiber refractometers
    (SPIE, 2012) Sánchez Zábal, Pedro; Ruiz Zamarreño, Carlos; Hernáez Sáenz de Zaitigui, Miguel; Del Villar, Ignacio; Matías Maestro, Ignacio; Arregui San Martín, Francisco Javier; Ingeniería Eléctrica y Electrónica; Ingeniaritza Elektrikoa eta Elektronikoa; Gobierno de Navarra / Nafarroako Gobernua
    In this work, the fabrication and characterization of refractometers based on lossy mode resonances (LMR) is presented. Tin dioxide (SnO2) films deposited on optical fibers are used as the LMR supporting coatings. These resonances shift to the red as a function of the external refractive index, enabling the fabrication of robust and highly reproducible wavelength-based optical fiber refractometers. The obtained SnO2-based refractometer shows an average sensitivity of 7198 nm/refractive index unit (RIU) in the range 1.333-1.420 RIU.
  • PublicationOpen Access
    Fiber-optic biosensor based on lossy mode resonances
    (Elsevier, 2012) Socorro Leránoz, Abián Bentor; Corres Sanz, Jesús María; Del Villar, Ignacio; Arregui San Martín, Francisco Javier; Matías Maestro, Ignacio; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren; Institute of Smart Cities - ISC; Ingeniería Eléctrica, Electrónica y de Comunicación
  • PublicationOpen Access
    Detection of ethanol in human breath using optical fiber long period grating coated with metal-organic frameworks
    (MDPI, 2017) Acha Morrás, Nerea de; Hromadka, Jiri; Tokay, Begum; Correia, Ricardo; Elosúa Aguado, César; Matías Maestro, Ignacio; Arregui San Martín, Francisco Javier; Morgan, Stephen P.; Korposh, Sergiy; Ingeniaritza Elektrikoa eta Elektronikoa; Institute for Advanced Materials and Mathematics - INAMAT2; Ingeniería Eléctrica y Electrónica
    An optical fiber sensor for ethanol detection in exhaled breath has been developed. It has been fabricated by functionalizing a Long Period Grating with a metal-organic framework, ZIF-8. The sensor’s response was tested by exposure to exhaled breath of a person before and after the ingestion of alcoholic drinks, showing a higher wavelength difference between the resonance bands in the second case. Further work will analyze cross-sensitivity towards temperature, relative humidity and carbon dioxide.
  • PublicationOpen Access
    Fiber-optic immunosensor based on lossy mode resonances induced by indium tin oxide thin-films
    (IEEE, 2017) Socorro Leránoz, Abián Bentor; Del Villar, Ignacio; Corres Sanz, Jesús María; Arregui San Martín, Francisco Javier; Matías Maestro, Ignacio; Ingeniería Eléctrica y Electrónica; Ingeniaritza Elektrikoa eta Elektronikoa; Institute of Smart Cities - ISC
    A novel immunosensor based on lossy mode resonances (LMRs) induced in optical fibers is developed in this contribution. Indium tin oxide (ITO) is sputtered on the optical substrate to generate an LMR in the transmission spectrum. Type G immunoglobulins (IgGs) are then attached to the ITO-coated fiber using (3-glycidyloxypropyl)trimethoxysilane (GPTMS). A phosphate buffer saline solution containing anti-IgGs is used to detect the biological reactions. The presented device is capable of detecting anti-IgG concentrations up to 10 nM. These results will permit the fabrication of biosensors based on a covalent attachment of bioreceptors over an LMR inducing thin-film.
  • PublicationOpen Access
    Thin film coated D-shaped fiber regenerable biosensor
    (Optica, 2020) Santano Rivero, Desiree; Ciáurriz Gortari, Paula; Tellechea Malda, Edurne; Zubiate Orzanco, Pablo; Socorro Leránoz, Abián Bentor; Del Villar, Ignacio; Matías Maestro, Ignacio; Arregui San Martín, Francisco Javier; Ingeniería Eléctrica, Electrónica y de Comunicación; Ingeniaritza Elektrikoa, Elektronikoa eta Telekomunikazio Ingeniaritza; Institute of Smart Cities - ISC
    We present a novel covalent functionalization of a D-shape fiber biosensor based on Lossy Mode Resonances. IgG/anti-IgG model is applied to prove the regeneration of the union and thus the re-usability of the sensor.
  • PublicationOpen Access
    Lossy mode resonance enabling ultra-low detection limit for fibre-optic biosensors (INVITED)
    (Springer, 2020) Chiavaioli, Francesco; Giannetti, Ambra; Tombelli, Sara; Trono, Cosimo; Del Villar, Ignacio; Matías Maestro, Ignacio; Zubiate Orzanco, Pablo; Ruiz Zamarreño, Carlos; Arregui San Martín, Francisco Javier; Baldini, Francesco; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren; Institute of Smart Cities - ISC; Ingeniería Eléctrica, Electrónica y de Comunicación; Gobierno de Navarra / Nafarroako Gobernua, 72/2015
    The combination of optical fibre-based biosensors with nanotechnologies is providing the opportunity for the development of in situ, portable, lightweight, versatile and high-sensitivity optical sensing platforms. We report on the generation of lossy mode resonances (LMRs) by means of the deposition of nm-thick SnO2 film on optical fibres. This allows measuring precisely and accurately the changes in refractive index of the fibre-surrounding medium with very high sensitivity compared to other optical technology platforms, such as long period grating or surface plasmon resonance. This approach, mixed with the use of specialty fiber structures such as Dshaped fibres, allows improving the light-matter interaction in strong way. Different imaging systems, i.e. SEM and TEM along with X-EDS tool, have been used to study the optical features of the fiber coating. The shift of the LMR has been monitored in real-time thanks to conventional wavelength interrogation system and ad hoc developed microfluidics. A big leap in performance has been attained by detecting femtomolar concentrations in human serum. The biosensor reusability has been also tested by using a solution of sodium dodecyl sulphate.
  • PublicationOpen Access
    Optical fiber vacuum sensor based on modal interferometer and PDMS coating
    (IEEE, 2019) Ascorbe Muruzabal, Joaquín; Fuentes Lorenzo, Omar; Corres Sanz, Jesús María; Arregui San Martín, Francisco Javier; Matías Maestro, Ignacio; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren; Institute of Smart Cities - ISC; Ingeniería Eléctrica, Electrónica y de Comunicación
    This work studies the behavior of polydimethylsiloxane (PDMS) as a transducer for optical vacuum pressure measurements. The optical structure chosen for this device is a modal interferometer achieved by splicing a coreless multimode optical fiber between two single mode fibers. Then, an etching process is applied to the obtained device, in order to decrease the diameter of the fiber and increase the sensitivity. Finally, the fiber is coated by dip-coating with a layer of PDMS, which changes its volume with pressure changes. The device has been studied in the 1x10(-3) mbar to 10 mbar range with a wavelength shift of 4 nm. A maximum sensitivity of 35 nm/mbar was obtained. The simple fabrication process, which can be applied to more sensitive structures, suggest that PDMS can be a good choice for the development of optical fiber vacuum sensors.
  • PublicationOpen Access
    D-shape optical fiber refractometer based on TM and TE lossy mode resonances
    (SPIE, 2014) Zubiate Orzanco, Pablo; Ruiz Zamarreño, Carlos; Del Villar, Ignacio; Matías Maestro, Ignacio; Arregui San Martín, Francisco Javier; Ingeniería Eléctrica, Electrónica y de Comunicación; Ingeniaritza Elektrikoa, Elektronikoa eta Telekomunikazio Ingeniaritza
    The fabrication and characterization of an optical fiber refractometer based on Lossy Mode Resonances (LMR) is presented. TiO2/ poly (sodium 4-styrenesulfonate) coatings deposited on side-polished D-shaped optical fibers are used as LMR supporting coatings. LMRs are sensitive to the external medium refractive index and D-shaped optical fibers enable the observation of TE and TM LMR polarizations. These refractometers based on TE and TM LMR showed an average sensitivity of 2737 nm/RIU and 2893 nm/RIU respectively for a surrounding medium refractive index (SMRI) range from 1.35 to 1.41.