Villanueva Larre, Arantxa

Loading...
Profile Picture

Email Address

Birth Date

Job Title

Last Name

Villanueva Larre

First Name

Arantxa

person.page.departamento

Ingeniería Eléctrica, Electrónica y de Comunicación

person.page.instituteName

ISC. Institute of Smart Cities

person.page.observainves

person.page.upna

Name

Search Results

Now showing 1 - 10 of 18
  • PublicationOpen Access
    Contributions of artificial intelligence to low resolution renal multiparametric magnetic resonance analysis
    (2021) Oyarzun Domeño, Anne; Villanueva Larre, Arantxa; Ingeniería Eléctrica, Electrónica y de Comunicación; Institute of Smart Cities - ISC; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren
    Arterial spin labeling (ASL), is a Multiparametric Magnetic Resonance Imaging (MRI) technique used to quantify and evaluate Renal Blood Flow (RBF) and detect perfusion failure by labelling blood water as it flows throughout the kidney. This study aims at providing an automatic quantifying and evaluation tool for Chronic Kidney Disease (CKD) patients’s follow-up.
  • PublicationOpen Access
    Beyond basic tuning: exploring discrepancies in user and setup calibration for gaze estimation
    (ACM, 2024-06-04) Garde Lecumberri, Gonzalo; Armendáriz Armenteros, José María; Beruete Cerezo, Rubén; Cabeza Laguna, Rafael; Villanueva Larre, Arantxa; Ingeniería Eléctrica, Electrónica y de Comunicación; Ingeniaritza Elektrikoa, Elektronikoa eta Telekomunikazio Ingeniaritza
    Calibrating gaze estimation models is crucial to maximize the effectiveness of these systems, although its implementation also poses challenges related to usability. Therefore, the simplification of this process is key. In this work, we dissect the impact of calibration due to both the environment and the user in gaze estimation models that employ general-purpose devices. We aim to replicate a workflow close to the final application by starting with pre-trained models and subsequently calibrating them using different strategies, testing under various camera arrangements and user-specific variability. The results indicate differentiation between the impact due to the user and the setup, being the components due to the users a slightly more pronounced impact than those related to the setup, opening the door to understanding calibration as a composite process. In any case, the development of calibration-free remote gaze estimation solutions remains a great challenge, given the crucial role of calibration.
  • PublicationOpen Access
    An image-based framework for the analysis of the murine microvasculature: from tissue clarification to computational hemodynamics
    (MDPI, 2022) Mañosas Sánchez, Santiago; Sanz Muñoz, Aritz; Ederra, Cristina; Urbiola, Ainhoa; Rojas De Miguel, Elvira; Ostiz, Ainhoa; Cortés Domínguez, Iván; Ramírez, Natalia; Ortiz de Solórzano, Carlos; Villanueva Larre, Arantxa; Malvè, Mauro; Ingeniería; Ingeniaritza
    The blood–brain barrier is a unique physiological structure acting as a filter for every molecule reaching the brain through the blood. For this reason, an effective pharmacologic treatment supplied to a patient by systemic circulation should first be capable of crossing the barrier. Standard cell cultures (or those based on microfluidic devices) and animal models have been used to study the human blood–brain barrier. Unfortunately, these tools have not yet reached a state of maturity because of the complexity of this physiological process aggravated by a high heterogeneity that is not easily recapitulated experimentally. In fact, the extensive research that has been performed and the preclinical trials carried out provided sometimes contradictory results, and the functionality of the barrier function is still not fully understood. In this study, we have combined tissue clarification, advanced microscopy and image analysis to develop a one-dimensional computational model of the microvasculature hemodynamics inside the mouse brain. This model can provide information about the flow regime, the pressure field and the wall shear stress among other fluid dynamics variables inside the barrier. Although it is a simplified model of the cerebral microvasculature, it allows a first insight on into the blood–brain barrier hemodynamics and offers several additional possibilities to systematically study the barrier microcirculatory processes.
  • PublicationOpen Access
    Multiparametric renal magnetic resonance imaging: a reproducibility study in renal allografts with stable function
    (Wiley, 2023) Echeverría Chasco, Rebeca; Martín Moreno, Paloma L.; Vidorreta, Marta; Aramendía Vidaurreta, Verónica; Cano, David; Villanueva Larre, Arantxa; Bastarrika, Gorka; Fernández Seara, María A.; García Fernández, Nuria; Ingeniería Eléctrica, Electrónica y de Comunicación; Institute of Smart Cities - ISC; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren
    Monitoring renal allograft function after transplantation is key for the early detection of allograft impairment, which in turn can contribute to preventing the loss of the allograft. Multiparametric renal MRI (mpMRI) is a promising noninvasive technique to assess and characterize renal physiopathology; however, few studies have employed mpMRI in renal allografts with stable function (maintained function over a long time period). The purposes of the current study were to evaluate the reproducibility of mpMRI in transplant patients and to characterize normal values of the measured parameters, and to estimate the labeling efficiency of Pseudo-Continuous Arterial Spin Labeling (PCASL) in the infrarenal aorta using numerical simulations considering experimental measurements of aortic blood flow profiles. The subjects were 20 transplant patients with stable kidney function, maintained over 1 year. The MRI protocol consisted of PCASL, intravoxel incoherent motion, and T1 inversion recovery. Phase contrast was used to measure aortic blood flow. Renal blood flow (RBF), diffusion coefficient (D), pseudo-diffusion coefficient (D*), flowing fraction (f), and T1 maps were calculated and mean values were measured in the cortex and medulla. The labeling efficiency of PCASL was estimated from simulation of Bloch equations. Reproducibility was assessed with the within-subject coefficient of variation, intraclass correlation coefficient, and Bland-Altman analysis. Correlations were evaluated using the Pearson correlation coefficient. The significance level was p less than 0.05. Cortical reproducibility was very good for T1, D, and RBF, moderate for f, and low for D*, while medullary reproducibility was good for T1 and D. Significant correlations in the cortex between RBF and f (r = 0.66), RBF and eGFR (r = 0.64), and D* and eGFR (r = 0.57) were found. Normal values of the measured parameters employing the mpMRI protocol in kidney transplant patients with stable function were characterized and the results showed good reproducibility of the techniques.
  • PublicationOpen Access
    Attention to product images in an online retailing store: an eye-tracking study considering consumer goals and type of product
    (California State University Press, 2022) Chocarro Eguaras, Raquel; Cortiñas Ugalde, Mónica; Villanueva Larre, Arantxa; Institute for Advanced Research in Business and Economics - INARBE; Institute of Smart Cities - ISC
    The visual content of the product area is crucial in an e-commerce site. This paper studies the differences in attention to product images in the product area in e-commerce sites considering the effects of purchase stage and product category. Attention to product images on websites is measured using eye-tracking in two experiments with 58 students and 66 subjects, with four product categories and four purchase tasks in each one. Our results show that pictures, in general, attract attention first, before the product names and price information. Furthermore, images attract less total attention than textual information. Images attract less attention when they are not crucial for completing the task, such as when purchasing a determined product or when locating product tracking information. Younger people (less than 30) spend much less time viewing the product pictures than older age groups (50 or more). According to our results, e-retailers could improve their sites’ performance by adapting the products’ presentation to the purchase tasks and visitor characteristics.
  • PublicationOpen Access
    Differences in specific abdominal fat depots between metabolically healthy and unhealthy children with overweight/obesity: the role of cardiorespiratory fitness
    (Wiley, 2023) Cadenas-Sánchez, Cristina; Medrano Echeverría, María; Villanueva Larre, Arantxa; Cabeza Laguna, Rafael; Idoate, Fernando; Osés Recalde, Maddi; Rodríguez Vigil, Beatriz; Álvarez de Eulate, Natalia; Alberdi Aldasoro, Nerea; Ortega, Francisco B.; Labayen Goñi, Idoia; Ciencias de la Salud; Ingeniería Eléctrica, Electrónica y de Comunicación; Institute on Innovation and Sustainable Development in Food Chain - ISFOOD; Institute of Smart Cities - ISC; Osasun Zientziak; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren
    Objectives: Fat depots localization has a critical role in the metabolic health status of adults. Nevertheless, whether that is also the case in children remains under- studied. Therefore, the aims of this study were: (i) to examine the differ-ences between metabolically healthy (MHO) and unhealthy (MUO) overweight/obesity phenotypes on specific abdominal fat depots, and (ii) to further explore whether cardiorespiratory fitness plays a major role in the differences between metabolic phenotypes among children with overweight/obesity. Methods: A total of 114 children with overweight/obesity (10.6 ±1.1 years, 62 girls) were included. Children were classified as MHO (n=68) or MUO. visceral (VAT), abdominal subcutaneous (ASAT), intermuscular abdominal (IMAAT), psoas, hepatic, pancreatic, and lumbar bone marrow adipose tissues were measured by magnetic resonance imaging. Cardiorespiratory fitness was assessed using the 20 m shuttle run test. Results: MHO children had lower VAT and ASAT contents and psoas fat fraction compared to MUO children (difference =12.4%– 25.8%, all p<0.035). MUO- unfit had more VAT and ASAT content than those MUO- fit and MHO- fit (difference =34.8%– 45.3%, all p<0.044). MUO- unfit shows also greater IMAAT fat fraction than those MUO- fit and MHO- fit peers (difference =16.4%– 13.9% respectively, all p≤0.001). In addition, MHO- unfit presented higher IMAAT fat fraction than MHO- fit (difference =13.4%, p<0.001). MUO- unfit presented higher psoas fat fraction than MHO- fit (difference =29.1%, p=0.008). Conclusions: VAT together with ASAT and psoas fat fraction, were lower in MHO than in MUO children. Further, we also observed that being fit, regardless of metabolic phenotype, has a protective role over the specific abdominal fat depots among children with overweight/obesity.
  • PublicationOpen Access
    Advancing ASL kidney image registration: a tailored pipeline with VoxelMorph
    (Springer, 2025-01-31) Oyarzun Domeño, Anne; Cia Alonso, Izaskun; Echeverría Chasco, Rebeca; Fernández Seara, María A.; Martín Moreno, Paloma L.; García Fernández, Nuria; Bastarrika, Gorka; Navallas Irujo, Javier; Villanueva Larre, Arantxa; Ingeniería Eléctrica, Electrónica y de Comunicación; Ingeniaritza Elektrikoa, Elektronikoa eta Telekomunikazio Ingeniaritza; Institute of Smart Cities - ISC; Universidad Pública de Navarra / Nafarroako Unibertsitate Publikoa; Gobierno de Navarra / Nafarroako Gobernua
    In clinical renal assessment, image registration plays a pivotal role, as patient movement during data acquisition can significantly impede image post-processing and the accurate estimation of hemodynamic parameters. This study introduces a deep learning-based image registration framework specifically for arterial spin labeling (ASL) imaging. ASL is a magnetic resonance imaging technique that modifies the longitudinal magnetization of blood perfusing the kidney using a series of radiofrequency pulses combined with slice-selective gradients. After tagging the arterial blood, label images are captured following a delay, allowing the tagged blood bolus to enter the renal tissue, while control images are acquired without tagging the arterial spins. Given that perfusion maps are generated at the pixel level by subtracting control images from label images and considering the relatively small signal intensity difference, precise alignment of these images is crucial to minimize motion artefacts and prevent significant errors in perfusion calculations. Moreover, due to the extended ASL acquisition times and the anatomical location of the kidneys, renal images are often susceptible to pulsation, peristalsis, and breathing motion. These motion-induced noises and other instabilities can adversely affect ASL imaging outcomes, making image registration essential. However, research on renal MRI registration, particularly with respect to learning-based techniques, remains limited, with even less focus on renal ASL. Our study proposes a learning-based image registration approach that builds upon VoxelMorph and introduces groupwise inference as a key enhancement. The dataset includes 2448 images of transplanted kidneys (TK) and 2456 images of healthy kidneys (HK). We compared the automatic image registration results with the widely recognized optimization method Elastix. The model’s performance was evaluated using the mean structural similarity index (MSSIM), normalized correlation coefficient (NCC), temporal signal-tonoise ratio (TSNR) of the samples, and the mean cortical signal (CSIM) in perfusion-weighted images, thereby extending the evaluation beyond traditional similarity-based metrics. Our method achieved superior image registration performance, with peak NCC (0.987 ± 0.006) and MSSIM (0.869 ± 0.048) values in the kidney region, significantly surpassing Elastix and the unregistered series (p\ 0.05) on TK and HK datasets. Regularization analysis showed that higher k values (1, 2) produced smoother deformation fields, while moderate k values (0.5, 0.9) balanced smoothness and detail, maintaining low non-positive Jacobian percentages (\1%) comparable to Elastix. Additionally, our method improved CSIM by 14.3% (2.304 ± 1.167) and TSNR by 13.1% (3.888 ± 2.170) in TK, and achieved up to 13.2% (CSIM) and 29.8% (TSNR) enhancements in HK, demonstrating robustness and improved signal quality across datasets and acquisition techniques.
  • PublicationOpen Access
    Effects of time-restricted eating and resistance training on skeletal muscle tissue quantity, quality and function in postmenopausal women with overweight or obesity: a study protocol
    (Elsevier, 2024-12-30) Alfaro-Magallanes, Víctor Manuel; Medrano Echeverría, María; Echarte Medina, Jon; Osés Recalde, Maddi; Izquierdo Rodríguez, Claudia; Concepción Álvarez, Mara de la Caridad; Galbete Jiménez, Arkaitz; Idoate, Fernando; Zugasti Murillo, Ana; Petrina Jáuregui, María Estrella; Goñi Gironés, María Elena; Ribelles, María Jesús; Amasene, María; Arenaza Etxeberría, Lide; Tejada Garrido, Clara Isabel; Elejalde, E.; Azcárate Jiménez, Unai Xabier; Ruiz Sarrias, Oskitz; Sayar-Beristain, Onintza; García-Ramos, Amador; Martínez Labari, Cristina; Armendáriz Brugos, Cristina; Villanueva Larre, Arantxa; Ruiz Ruiz, Jonatan; Cabeza Laguna, Rafael; Labayen Goñi, Idoia; Ciencias de la Salud; Osasun Zientziak; Institute of Smart Cities - ISC; Ingeniería Eléctrica, Electrónica y de Comunicación; Ingeniaritza Elektrikoa, Elektronikoa eta Telekomunikazio Ingeniaritza; Estadística, Informática y Matemáticas; Estatistika, Informatika eta Matematika; Institute on Innovation and Sustainable Development in Food Chain - ISFOOD
    Background & aims: time-restricted eating (TRE) shows promise for weight loss and improving menopauserelated body composition and cardiometabolic health, but its effects on skeletal muscle tissue (SMT) in postmenopausal women are unknown. This study investigates the effects of three weight loss interventions over 12 weeks on SMT quantity, quality, function, and cardiometabolic health in postmenopausal women with overweight/obesity, with effects persistence evaluated at a 12-month follow-up. Methods and results: in this randomized controlled trial, 78 postmenopausal women (50–65 years; BMI 25–40 kg/m2; sedentary lifestyle; eating window ≥12 h/day; no severe metabolic impairments) will be recruited. Participants will be randomly assigned to one of three groups for 12 weeks: TRE, TRE + resistance training, or CR + resistance training. The TRE groups will reduce their eating window to 8 h and receive nutritional advice to adhere to a Mediterranean diet. The CR group will follow a personalized hypocaloric diet (− 500 kcal/day). Resistance training groups will perform supervised resistance training 3 times/week. Primary Outcome: Change in SMT quantity measured by MRI at baseline and after 12 weeks. Secondary Outcomes: intermuscular adipose tissue (IMAT), strength, power, body weight and composition, and cardiometabolic risk factors. Conclusion: this study will illustrate the effects of TRE and TRE combined with resistance exercise compared with the currently recommended obesity-lifestyle treatment on SMT quantity, quality, function, and cardiometabolic markers. The results will offer insights into dietary strategies to combat obesity and metabolic diseases without increasing sarcopenia risk in postmenopausal women, a sparsely studied and particularly affected population.
  • PublicationOpen Access
    Low cost gaze estimation: knowledge-based solutions
    (IEEE, 2020) Martinikorena Aranburu, Ion; Larumbe Bergera, Andoni; Ariz Galilea, Mikel; Porta Cuéllar, Sonia; Cabeza Laguna, Rafael; Villanueva Larre, Arantxa; Ingeniería Eléctrica, Electrónica y de Comunicación; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren
    Eye tracking technology in low resolution scenarios is not a completely solved issue to date. The possibility of using eye tracking in a mobile gadget is a challenging objective that would permit to spread this technology to non-explored fields. In this paper, a knowledge based approach is presented to solve gaze estimation in low resolution settings. The understanding of the high resolution paradigm permits to propose alternative models to solve gaze estimation. In this manner, three models are presented: a geometrical model, an interpolation model and a compound model, as solutions for gaze estimation for remote low resolution systems. Since this work considers head position essential to improve gaze accuracy, a method for head pose estimation is also proposed. The methods are validated in an optimal framework, I2Head database, which combines head and gaze data. The experimental validation of the models demonstrates their sensitivity to image processing inaccuracies, critical in the case of the geometrical model. Static and extreme movement scenarios are analyzed showing the higher robustness of compound and geometrical models in the presence of user’s displacement. Accuracy values of about 3◦ have been obtained, increasing to values close to 5◦ in extreme displacement settings, results fully comparable with the state-of-the-art.
  • PublicationOpen Access
    Diagnostic and prognostic potential of multiparametric renal MRI in Kidney transplant patients
    (Wiley, 2024) Echeverría Chasco, Rebeca; Martín Moreno, Paloma L.; Aramendía Vidaurreta, Verónica; García-Ruiz, Leyre; Mora-Gutiérrez, José María; Vidorreta Díaz de Cerio, Marta; Villanueva Larre, Arantxa; Cano, David; Bastarrika, Gorka; Fernández Seara, María A.; Ingeniería Eléctrica, Electrónica y de Comunicación; Institute of Smart Cities - ISC; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren
    Background: Multiparametric MRI provides assessment of functional and structural parameters in kidney allografts. Itoffers a non-invasive alternative to the current reference standard of kidney biopsy. Purpose: To evaluate the diagnostic and prognostic utility of MRI parameters in the assessment of allograft function in thefirst 3-months post-transplantation. Study Type: Prospective. Subjects: 32 transplant recipients (54 17 years, 20 females), divided into two groups according to estimated glomerularfiltration rate (eGFR) at 3-months post-transplantation: inferior graft function (IGF; eGFR<45 mL/min/1.73 m2,n=10) andsuperior graft function (SGF; eGFR≥45 mL/min/1.73 m2,n=22). Further categorization was based on the need for hemo-dialysis (C1) and decrease in s-creatinine (C2) at 1-week post-transplantation: delayed-graft-function (DGF:n=4 C1,n=10 C2) and early graft-function (EGF:n=28 C1,n=22 C2). Field Strength/Sequence: 3-T, pseudo-continuous arterial spin labeling, T1-mapping, and diffusion-weighted imaging. Assessment: Multiparametric MRI was evaluated at 1-week in all patients and 3-months after transplantation in 28 patients. Renalbloodflow (RBF), diffusion coefficients (ADC,ΔADC,D,ΔD,D*,flowing fractionf),T1andΔT1were calculated in cortex andmedulla. The diagnostic and prognostic value of these parameters, obtained at 3-months and 1-week post-transplantation,respectively, was evaluated in the cortex to discriminate between DGF and EGF, and between SGF and IGF. Statistical Tests: Logistic regression, receiver-operating-characteristics, area-under-the-curve (AUC), confidence intervals(CIs), analysis-of-variance,t-test, Wilcoxon-Mann–Whitney test, Fisher’s exact test, Pearson’s correlation.P-value<0.05 wasconsidered significant. Results: DGF patients exhibited significantly lower cortical RBF and f and higherD*. The diagnostic value of MRI fordetecting DGF was excellent (AUC=100%). Significant differences between patients with IGF and SGF were found inRBF,ΔT1, andΔD. Multiparametric MRI showed higher diagnostic (AUC=95.32%; CI: 88%–100%) and prognostic(AUC=97.47%, CI: 92%–100%) values for detecting IGF than eGFR (AUC=89.50%, CI: 79%–100%). Data Conclusion: Multiparametric MRI may show high diagnostic and prognostic value in transplanted patients, yieldingbetter results compared to eGFR measurements. Level of Evidence: 2. Technical Efficacy: Stage 1.