Algueta-Miguel, Jose M.
Loading...
Email Address
person.page.identifierURI
Birth Date
Job Title
Last Name
Algueta-Miguel
First Name
Jose M.
person.page.departamento
Ingeniería Eléctrica, Electrónica y de Comunicación
person.page.instituteName
ORCID
person.page.observainves
person.page.upna
Name
- Publications
- item.page.relationships.isAdvisorOfPublication
- item.page.relationships.isAdvisorTFEOfPublication
- item.page.relationships.isAuthorMDOfPublication
2 results
Search Results
Now showing 1 - 2 of 2
Publication Open Access Analog lock-in amplifier design using subsampling for accuracy enhancement in GMI sensor applications(MDPI, 2023) Algueta-Miguel, Jose M.; Beato López, Juan Jesús; López Martín, Antonio; Ciencias; Zientziak; Institute of Smart Cities - ISC; Institute for Advanced Materials and Mathematics - INAMAT2; Universidad Pública de Navarra / Nafarroako Unibertsitate Publikoa, PJUPNA2005A frequency downscaling technique for enhancing the accuracy of analog lock-in amplifier (LIA) architectures in giant magneto-impedance (GMI) sensor applications is presented in this paper. As a proof of concept, the proposed method is applied to two different LIA topologies using, respectively, analog and switching-based multiplication for phase-sensitive detection. Specifically, the operation frequency of both the input and the reference signals of the phase-sensitive detector (PSD) block of the LIA is reduced through a subsampling process using sample-and-hold (SH) circuits. A frequency downscaling from 200 kHz, which is the optimal operating frequency of the employed GMI sensor, to 1 kHz has been performed. In this way, the proposed technique exploits the inherent advantages of analog signal multiplication at low frequencies, while the principle of operation of the PSD remains unaltered. The circuits were assembled using discrete components, and the frequency downscaling proposal was experimentally validated by comparing the measurement accuracy with the equivalent conventional circuits. The experimental results revealed that the error in the signal magnitude measurements was reduced by a factor of 8 in the case of the analog multipliers and by a factor of 21 when a PSD based on switched multipliers was used. The error in-phase detection using a two-phase LIA was also reduced by more than 25%.Publication Open Access A lock-in amplifier for magnetic nanoparticle detection using GMI sensors(IEEE, 2024-09-30) Algueta-Miguel, Jose M.; Beato López, Juan Jesús; López Martín, Antonio; Gómez Polo, Cristina; Ciencias; Zientziak; Ingeniería Eléctrica, Electrónica y de Comunicación; Ingeniaritza Elektrikoa, Elektronikoa eta Telekomunikazio Ingeniaritza; Institute for Advanced Materials and Mathematics - INAMAT2; Institute of Smart Cities - ISCA digital lock-in amplifier (LIA) for contactless magnetic nanoparticle (MNP) detection using giant magnetoimpedance (GMI) sensors is presented. The proposed approach is based on the simultaneous detection of the second harmonic amplitude and phase. A Xilinx Artix-7 field-programmable gate array (FPGA) has been employed for efficiently implementing the phase-sensitive detection (PSD) and the subsequent digital processing. The analog GMI sensor interface has been designed for minimizing the dependence of the excitation current on the GMI sensor impedance, also enhancing the rejection of the parasitic second-order distortion produced by the setup. A subsampling process of the analog outputs has been applied, both increasing the effective resolution of the analog-to-digital converter (ADC) and facilitating signal recovery. The proposed system improves the MNP detection capability reported in previous works using the second harmonic amplitude. Moreover, a characterization of the phase response, which had not been previously studied in the literature, is also provided.