Ruiz ZamarreƱo, Carlos
Loading...
Email Address
person.page.identifierURI
Birth Date
Job Title
Last Name
Ruiz ZamarreƱo
First Name
Carlos
person.page.departamento
IngenierĆa ElĆ©ctrica, Electrónica y de Comunicación
person.page.instituteName
ISC. Institute of Smart Cities
ORCID
person.page.observainves
person.page.upna
Name
- Publications
- item.page.relationships.isAdvisorOfPublication
- item.page.relationships.isAdvisorTFEOfPublication
- item.page.relationships.isAuthorMDOfPublication
10 results
Search Results
Now showing 1 - 10 of 10
Publication Open Access D-shape optical fiber refractometer based on TM and TE lossy mode resonances(SPIE, 2014) Zubiate Orzanco, Pablo; Ruiz ZamarreƱo, Carlos; Del Villar, Ignacio; MatĆas Maestro, Ignacio; Arregui San MartĆn, Francisco Javier; IngenierĆa ElĆ©ctrica, Electrónica y de Comunicación; Ingeniaritza Elektrikoa, Elektronikoa eta Telekomunikazio IngeniaritzaThe fabrication and characterization of an optical fiber refractometer based on Lossy Mode Resonances (LMR) is presented. TiO2/ poly (sodium 4-styrenesulfonate) coatings deposited on side-polished D-shaped optical fibers are used as LMR supporting coatings. LMRs are sensitive to the external medium refractive index and D-shaped optical fibers enable the observation of TE and TM LMR polarizations. These refractometers based on TE and TM LMR showed an average sensitivity of 2737 nm/RIU and 2893 nm/RIU respectively for a surrounding medium refractive index (SMRI) range from 1.35 to 1.41.Publication Open Access Optical fiber refractometers based on indium tin oxide coatings with response in the visible spectral region(Elsevier, 2011) Ruiz ZamarreƱo, Carlos; López, S.; HernĆ”ez SĆ”enz de Zaitigui, Miguel; Del Villar, Ignacio; MatĆas Maestro, Ignacio; Arregui San MartĆn, Francisco Javier; IngenierĆa ElĆ©ctrica y Electrónica; Ingeniaritza Elektrikoa eta Elektronikoa; Gobierno de Navarra / Nafarroako GobernuaThis work presents the fabrication of optical fiber refractometers based on indium tin oxide (ITO) coatings with response in the visible spectral region. ITO thin-films have been sputtered by employing a rotating mechanism that enables the fabrication of smooth homogeneous coatings onto the optical fiber core. The ITO coated optical fiber devices present several resonances in the visible and infra-red region. These resonances show high optical power attenuations (more than 10 dB) in the visible spectral region, which produces changes in the colour of the output visible light. Therefore, since these resonances shift as a function of the surrounding medium refractive index (SMRI), it is feasible to determine the refractive index of the outer medium in contact with the ITO coating by simply monitoring the chromatic coordinates of the visible output light.Publication Open Access Optical fiber thermo-refractometer(Optica, 2022) Imas GonzĆ”lez, JosĆ© Javier; Ruiz ZamarreƱo, Carlos; Del Villar, Ignacio; Cardozo da Silva, Jean Carlos; Oliveira, V.; MatĆas Maestro, Ignacio; IngenierĆa ElĆ©ctrica, Electrónica y de Comunicación; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio IngeniaritzarenThis work presents the implementation of a thermo-refractometer, which integrates the measurement of both refractive index and temperature in a single optical fiber structure. To this purpose, a lossy mode resonance (LMR)-based refractometer is obtained by means of the deposition of a titanium dioxide (TiO2) thin film onto a side-polished (D-shaped) single mode fiber. Measurement and subsequent temperature compensation are achieved by means of a fiber Bragg grating (FBG) inscribed in the core of the D-shaped region. The LMR wavelength shift is monitored in transmission while the FBG (FBG peak at 1533 nm) displacement is observed in reflection. The LMR is sensitive to both the surrounding refractive index (SRI), with a sensitivity of 3725.2 nm/RIU in the 1.3324-1.3479 range, and the temperature (- 0.186 nm/°C); while the FBG is only affected by the temperature (32.6 pm/°C in the 25°C - 45°C range). With these values, it is possible to recover the SRI and temperature variations from the wavelength shifts of the LMR and the FBG, constituting a thermo-refractometer, where it is suppressed the effect of the temperature over the refractometer operation, which could cause errors in the fourth or even third decimal of the measured SRI value.Publication Open Access SnO2 based optical fiber refractometers(SPIE, 2012) SĆ”nchez ZĆ”bal, Pedro; Ruiz ZamarreƱo, Carlos; HernĆ”ez SĆ”enz de Zaitigui, Miguel; Del Villar, Ignacio; MatĆas Maestro, Ignacio; Arregui San MartĆn, Francisco Javier; IngenierĆa ElĆ©ctrica y Electrónica; Ingeniaritza Elektrikoa eta Elektronikoa; Gobierno de Navarra / Nafarroako GobernuaIn this work, the fabrication and characterization of refractometers based on lossy mode resonances (LMR) is presented. Tin dioxide (SnO2) films deposited on optical fibers are used as the LMR supporting coatings. These resonances shift to the red as a function of the external refractive index, enabling the fabrication of robust and highly reproducible wavelength-based optical fiber refractometers. The obtained SnO2-based refractometer shows an average sensitivity of 7198 nm/refractive index unit (RIU) in the range 1.333-1.420 RIU.Publication Open Access D-shape optical fiber pH sensor based on lossy mode resonances (LMRs)(IEEE, 2016-01-07) Zubiate Orzanco, Pablo; Ruiz ZamarreƱo, Carlos; Del Villar, Ignacio; MatĆas Maestro, Ignacio; Arregui San MartĆn, Francisco Javier; IngenierĆa ElĆ©ctrica, Electrónica y de Comunicación; Ingeniaritza Elektrikoa, Elektronikoa eta Telekomunikazio IngeniaritzaThe fabrication and characterization of an optical fiber pH sensor based on Lossy Mode Resonances (LMRs) is presented. PAH/PAA polymeric thin-films fabricated onto side-polished D-shaped optical fibers are used as LMR supporting coatings. The thickness of PAH/PAA coatings can be modified as a function of the external medium pH. As a consequence of this variation, the effective refractive index of the structure will change, producing a shift of the LMR. The fabricated sensor has been used to measure pH from 4.0 to 5.0. This pH sensor showed a sensitivity of 101.3 nm per pH unit, which means a resolution of ~6Ć10-4 pH units by using a conventional communications Optical Spectrum Analyzer (OSA), which is an improvement over commercial pH sensors.Publication Open Access Low cutoff wavelength etched SMS structures towards verification of the quality of automotive antifreeze(IEEE, 2020) RodrĆguez RodrĆguez, Wenceslao Eduardo; RodrĆguez RodrĆguez, Adolfo JosuĆ©; Ruiz ZamarreƱo, Carlos; Del Villar, Ignacio; Zúñiga AlanĆs, Manuel; IngenierĆa ElĆ©ctrica, Electrónica y de Comunicación; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren; Gobierno de Navarra / Nafarroako Gobernua, 2019 904 116; Universidad PĆŗblica de Navarra / Nafarroako Unibertsitate Publikoa, PJUPNA26Optical fiber single mode-multimode-single mode (SMS) structures can be used as wavelength detection-based sensors. In this work, we focus on the performance at short wavelengths, where optical sources and detectors are less expensive. Here, a self-image band with a high transmission power is monitored in this short-wavelength range. In addition, the diameter and the length of the SMS structure have been optimized in order to improve the sensitivity of the device. In this sense, a maximum refractive index sensitivity of 305 nm/RIU was achieved by an etched SMS with a diameter of 34μ m. Furthermore, the obtained devices were used for testing the quality of automotive coolant and antifreeze liquid.Publication Open Access Fiber-optic lossy mode resonance sensors(Elsevier, 2014) Arregui San MartĆn, Francisco Javier; Del Villar, Ignacio; Corres Sanz, JesĆŗs MarĆa; Goicoechea FernĆ”ndez, Javier; Ruiz ZamarreƱo, Carlos; ElosĆŗa Aguado, CĆ©sar; HernĆ”ez SĆ”enz de Zaitigui, Miguel; Rivero Fuente, Pedro J.; Socorro LerĆ”noz, AbiĆ”n Bentor; Urrutia Azcona, Aitor; SĆ”nchez ZĆ”bal, Pedro; Zubiate Orzanco, Pablo; López Torres, Diego; Acha MorrĆ”s, Nerea de; MatĆas Maestro, Ignacio; IngenierĆa ElĆ©ctrica y Electrónica; Ingeniaritza Elektrikoa eta Elektronikoa; Gobierno de Navarra / Nafarroako GobernuaIn the last 4 years, experimental evidences about the potential use of optical sensors based on Lossy Mode Resonances (LMR) have been presented in the literature. These LMR sensors have some similarities with Surface Plasmon Resonance (SPR) sensors, the gold standard in label-free, real-time biomolecular interaction analysis. In these new LMR sensors, if the non-metallic nanocladding of an optical waveguide fulfills the conditions explained in this work, coupling of light to the cladding modes happens at certain resonance wavelengths, which enables the use of LMR devices as refractometers and opens the door to diverse applications such as in biology and proteomics research. These highly sensitive refractometers have already shown sensitivities higher than 20,000 nm/RIU or 5x10-7 RIU and, given the youth of this field, it is expected to achieve even better values.Publication Open Access Tunable optical fiber pH sensors based on TE and TM Lossy Mode Resonances (LMRs)(Elsevier, 2016) Zubiate Orzanco, Pablo; Ruiz ZamarreƱo, Carlos; Del Villar, Ignacio; MatĆas Maestro, Ignacio; Arregui San MartĆn, Francisco Javier; Institute of Smart Cities - ISC; IngenierĆa ElĆ©ctrica y Electrónica; Ingeniaritza Elektrikoa eta ElektronikoaIn this paper, a high sensitivity optical fiber pH sensor based on lossy mode resonance (LMR) generated with transversal electric (TE) and transversal magnetic (TM) polarized light is presented. Poly(allylamine hydrochloride) (PAH)/poly(acrylic acid) (PAA) polymeric thin-films fabricated onto side-polished Dshaped optical fibers are used as pH-sensitive as well as LMR supporting coatings. The adequate selection of the pH-sensitive coating fabrication parameters enables to obtain devices working at different pH regions. Two devices have been obtained in order to measure pH from 4.0 to 5.0 and from 7.0 to 8.0 respectively. Obtained optical fiber pH sensors based on TE and TM LMRs showed a maximum sensitivity of 69 nm/pH, which means a resolution of ā¼0.0008 pH units by using a conventional communications Optical Spectrum Analyzer (OSA) with 0.06 nm resolution.Publication Open Access Experimental study and sensing applications of polarization-dependent lossy mode resonances generated by D-shape coated optical fibers(IEEE, 2015) Zubiate Orzanco, Pablo; Ruiz ZamarreƱo, Carlos; Del Villar, Ignacio; MatĆas Maestro, Ignacio; Arregui San MartĆn, Francisco Javier; IngenierĆa ElĆ©ctrica y Electrónica; Ingeniaritza Elektrikoa eta ElektronikoaThe fabrication and characterization of an optical fiber refractometer based on Lossy Mode Resonances (LMR) is presented. TiO2/ poly (sodium 4-styrenesulfonate) (PSS) coatings deposited on side-polished D-shaped optical fibers are used as LMR supporting coatings. LMRs are sensitive to the external medium refractive index and D-shaped optical fibers enable the observation of TE and TM LMR polarizations. These refractometers based on TE and TM LMR showed an average sensitivity of 2737 nm/RIU and 2893 nm/RIU respectively for a surrounding medium refractive index (SMRI) range from 1.35 to 1.41. This work also explores the utilization of previously described refractometers in the context of two common industrial applications such as the determination of the sugar content or °Brix in beverages and the salt concentration in sea water.Publication Open Access Optical fiber refractometers based on sputtered indium tin oxide coatings(IEEE, 2011) López, S.; Ruiz ZamarreƱo, Carlos; HernĆ”ez, M.; Del Villar, Ignacio; Arregui San MartĆn, Francisco Javier; MatĆas Maestro, Ignacio; IngenierĆa ElĆ©ctrica y Electrónica; Ingeniaritza Elektrikoa eta ElektronikoaThis work presents the fabrication of optical fiber refractometers based on indium tin oxide (ITO) coatings deposited by sputtering with response in the visible spectral region. ITO thin-films have been sputtered by employing a rotating mechanism that enables the fabrication of smooth and homogeneous coatings onto the optical fiber core. Fabricated ITO coated optical fiber devices present several resonances in the visible and near infrared region. These resonances show high optical power attenuations (more than 10 dB) in the visible spectral region, which produces changes in the colour of the output visible light. Therefore, since these resonances shift as a function of the refractive index (RI) of the surrounding medium it is feasible to determine the RI of the outer medium in contact with the ITO coating by simply monitoring the chromatic coordinates (colour change), x and y, of the visible output light