Ruiz Zamarreño, Carlos
Loading...
Email Address
person.page.identifierURI
Birth Date
Job Title
Last Name
Ruiz Zamarreño
First Name
Carlos
person.page.departamento
Ingeniería Eléctrica, Electrónica y de Comunicación
person.page.instituteName
ISC. Institute of Smart Cities
ORCID
person.page.observainves
person.page.upna
Name
- Publications
- item.page.relationships.isAdvisorOfPublication
- item.page.relationships.isAdvisorTFEOfPublication
- item.page.relationships.isAuthorMDOfPublication
12 results
Search Results
Now showing 1 - 10 of 12
Publication Open Access D-shape optical fiber refractometer based on TM and TE lossy mode resonances(SPIE, 2014) Zubiate Orzanco, Pablo; Ruiz Zamarreño, Carlos; Del Villar, Ignacio; Matías Maestro, Ignacio; Arregui San Martín, Francisco Javier; Ingeniería Eléctrica, Electrónica y de Comunicación; Ingeniaritza Elektrikoa, Elektronikoa eta Telekomunikazio IngeniaritzaThe fabrication and characterization of an optical fiber refractometer based on Lossy Mode Resonances (LMR) is presented. TiO2/ poly (sodium 4-styrenesulfonate) coatings deposited on side-polished D-shaped optical fibers are used as LMR supporting coatings. LMRs are sensitive to the external medium refractive index and D-shaped optical fibers enable the observation of TE and TM LMR polarizations. These refractometers based on TE and TM LMR showed an average sensitivity of 2737 nm/RIU and 2893 nm/RIU respectively for a surrounding medium refractive index (SMRI) range from 1.35 to 1.41.Publication Open Access High sensitive and selective C-reactive protein detection by means of lossy mode resonance based optical fiber devices(Elsevier, 2017) Zubiate Orzanco, Pablo; Ruiz Zamarreño, Carlos; Sánchez Zábal, Pedro; Matías Maestro, Ignacio; Arregui San Martín, Francisco Javier; Institute of Smart Cities - ISC; Ingeniería Eléctrica y Electrónica; Ingeniaritza Elektrikoa eta Elektronikoa; Universidad Pública de Navarra / Nafarroako Unibertsitate PublikoaThis work presents the development of high sensitive, selective, fast and reusable C-reactive protein (CRP) aptasensors. This novel approach takes advantage of the utilization of high sensitive refractometers based on Lossy Mode Resonances generated by thin indium tin oxide (ITO) films fabricated onto the planar region of D-shaped optical fibers. CRP selectivity is obtained by means of the adhesion of a CRP specific aptamer chain onto the ITO film using the Layer-by-Layer (LbL) nano-assembly fabrication process. The sensing mechanism relies on resonance wavelength shifts originated by refractive index variations of the aptamer chain in presence of the target molecule. Fabricated devices show high selectivity to CRP when compared with other target molecules, such as urea or creatinine, while maintaining a low detection limit (0.0625 mg/L) and fast response time (61 s). Additionally, these sensors show a repetitive response for several days and are reusable after a cleaning process in ultrapure water.Publication Open Access Optical fiber refractometers based on indium tin oxide coatings with response in the visible spectral region(Elsevier, 2011) Ruiz Zamarreño, Carlos; López, S.; Hernáez Sáenz de Zaitigui, Miguel; Del Villar, Ignacio; Matías Maestro, Ignacio; Arregui San Martín, Francisco Javier; Ingeniería Eléctrica y Electrónica; Ingeniaritza Elektrikoa eta Elektronikoa; Gobierno de Navarra / Nafarroako GobernuaThis work presents the fabrication of optical fiber refractometers based on indium tin oxide (ITO) coatings with response in the visible spectral region. ITO thin-films have been sputtered by employing a rotating mechanism that enables the fabrication of smooth homogeneous coatings onto the optical fiber core. The ITO coated optical fiber devices present several resonances in the visible and infra-red region. These resonances show high optical power attenuations (more than 10 dB) in the visible spectral region, which produces changes in the colour of the output visible light. Therefore, since these resonances shift as a function of the surrounding medium refractive index (SMRI), it is feasible to determine the refractive index of the outer medium in contact with the ITO coating by simply monitoring the chromatic coordinates of the visible output light.Publication Open Access Optical fiber thermo-refractometer(Optica, 2022) Imas González, José Javier; Ruiz Zamarreño, Carlos; Del Villar, Ignacio; Cardozo da Silva, Jean Carlos; Oliveira, V.; Matías Maestro, Ignacio; Ingeniería Eléctrica, Electrónica y de Comunicación; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio IngeniaritzarenThis work presents the implementation of a thermo-refractometer, which integrates the measurement of both refractive index and temperature in a single optical fiber structure. To this purpose, a lossy mode resonance (LMR)-based refractometer is obtained by means of the deposition of a titanium dioxide (TiO2) thin film onto a side-polished (D-shaped) single mode fiber. Measurement and subsequent temperature compensation are achieved by means of a fiber Bragg grating (FBG) inscribed in the core of the D-shaped region. The LMR wavelength shift is monitored in transmission while the FBG (FBG peak at 1533 nm) displacement is observed in reflection. The LMR is sensitive to both the surrounding refractive index (SRI), with a sensitivity of 3725.2 nm/RIU in the 1.3324-1.3479 range, and the temperature (- 0.186 nm/°C); while the FBG is only affected by the temperature (32.6 pm/°C in the 25°C - 45°C range). With these values, it is possible to recover the SRI and temperature variations from the wavelength shifts of the LMR and the FBG, constituting a thermo-refractometer, where it is suppressed the effect of the temperature over the refractometer operation, which could cause errors in the fourth or even third decimal of the measured SRI value.Publication Open Access Optical fiber sensors based on indium tin oxide surface plasmon resonance supporting coatings(SPIE, 2009-10-05) Ruiz Zamarreño, Carlos; Hernáez Sáenz de Zaitigui, Miguel; Matías Maestro, Ignacio; Arregui San Martín, Francisco Javier; Ingeniería Eléctrica y Electrónica; Ingeniaritza Elektrikoa eta ElektronikoaIn this work, surface plasmon resonance (SPR) based optical fiber sensors are revisited by using a transparent conductive coating, Indium Tin Oxide in our case, as the SPR supporting layer. The utilization of these coatings shifts the plasmon resonance band to the infra-red region and allows the tunability of the SPR wavelength by adjusting the film fabrication parameters. Here, we study the fabrication process of these novel devices and characterize their response to variations in the refractive index of the external medium opening the door to a wide range of applications.Publication Open Access SnO2 based optical fiber refractometers(SPIE, 2012) Sánchez Zábal, Pedro; Ruiz Zamarreño, Carlos; Hernáez Sáenz de Zaitigui, Miguel; Del Villar, Ignacio; Matías Maestro, Ignacio; Arregui San Martín, Francisco Javier; Ingeniería Eléctrica y Electrónica; Ingeniaritza Elektrikoa eta Elektronikoa; Gobierno de Navarra / Nafarroako GobernuaIn this work, the fabrication and characterization of refractometers based on lossy mode resonances (LMR) is presented. Tin dioxide (SnO2) films deposited on optical fibers are used as the LMR supporting coatings. These resonances shift to the red as a function of the external refractive index, enabling the fabrication of robust and highly reproducible wavelength-based optical fiber refractometers. The obtained SnO2-based refractometer shows an average sensitivity of 7198 nm/refractive index unit (RIU) in the range 1.333-1.420 RIU.Publication Open Access D-shape optical fiber pH sensor based on lossy mode resonances (LMRs)(IEEE, 2016-01-07) Zubiate Orzanco, Pablo; Ruiz Zamarreño, Carlos; Del Villar, Ignacio; Matías Maestro, Ignacio; Arregui San Martín, Francisco Javier; Ingeniería Eléctrica, Electrónica y de Comunicación; Ingeniaritza Elektrikoa, Elektronikoa eta Telekomunikazio IngeniaritzaThe fabrication and characterization of an optical fiber pH sensor based on Lossy Mode Resonances (LMRs) is presented. PAH/PAA polymeric thin-films fabricated onto side-polished D-shaped optical fibers are used as LMR supporting coatings. The thickness of PAH/PAA coatings can be modified as a function of the external medium pH. As a consequence of this variation, the effective refractive index of the structure will change, producing a shift of the LMR. The fabricated sensor has been used to measure pH from 4.0 to 5.0. This pH sensor showed a sensitivity of 101.3 nm per pH unit, which means a resolution of ~6×10-4 pH units by using a conventional communications Optical Spectrum Analyzer (OSA), which is an improvement over commercial pH sensors.Publication Open Access Fiber-optic lossy mode resonance sensors(Elsevier, 2014) Arregui San Martín, Francisco Javier; Del Villar, Ignacio; Corres Sanz, Jesús María; Goicoechea Fernández, Javier; Ruiz Zamarreño, Carlos; Elosúa Aguado, César; Hernáez Sáenz de Zaitigui, Miguel; Rivero Fuente, Pedro J.; Socorro Leránoz, Abián Bentor; Urrutia Azcona, Aitor; Sánchez Zábal, Pedro; Zubiate Orzanco, Pablo; López Torres, Diego; Acha Morrás, Nerea de; Matías Maestro, Ignacio; Ingeniería Eléctrica y Electrónica; Ingeniaritza Elektrikoa eta Elektronikoa; Gobierno de Navarra / Nafarroako GobernuaIn the last 4 years, experimental evidences about the potential use of optical sensors based on Lossy Mode Resonances (LMR) have been presented in the literature. These LMR sensors have some similarities with Surface Plasmon Resonance (SPR) sensors, the gold standard in label-free, real-time biomolecular interaction analysis. In these new LMR sensors, if the non-metallic nanocladding of an optical waveguide fulfills the conditions explained in this work, coupling of light to the cladding modes happens at certain resonance wavelengths, which enables the use of LMR devices as refractometers and opens the door to diverse applications such as in biology and proteomics research. These highly sensitive refractometers have already shown sensitivities higher than 20,000 nm/RIU or 5x10-7 RIU and, given the youth of this field, it is expected to achieve even better values.Publication Open Access Tunable optical fiber pH sensors based on TE and TM Lossy Mode Resonances (LMRs)(Elsevier, 2016) Zubiate Orzanco, Pablo; Ruiz Zamarreño, Carlos; Del Villar, Ignacio; Matías Maestro, Ignacio; Arregui San Martín, Francisco Javier; Institute of Smart Cities - ISC; Ingeniería Eléctrica y Electrónica; Ingeniaritza Elektrikoa eta ElektronikoaIn this paper, a high sensitivity optical fiber pH sensor based on lossy mode resonance (LMR) generated with transversal electric (TE) and transversal magnetic (TM) polarized light is presented. Poly(allylamine hydrochloride) (PAH)/poly(acrylic acid) (PAA) polymeric thin-films fabricated onto side-polished Dshaped optical fibers are used as pH-sensitive as well as LMR supporting coatings. The adequate selection of the pH-sensitive coating fabrication parameters enables to obtain devices working at different pH regions. Two devices have been obtained in order to measure pH from 4.0 to 5.0 and from 7.0 to 8.0 respectively. Obtained optical fiber pH sensors based on TE and TM LMRs showed a maximum sensitivity of 69 nm/pH, which means a resolution of ∼0.0008 pH units by using a conventional communications Optical Spectrum Analyzer (OSA) with 0.06 nm resolution.Publication Open Access Experimental study and sensing applications of polarization-dependent lossy mode resonances generated by D-shape coated optical fibers(IEEE, 2015) Zubiate Orzanco, Pablo; Ruiz Zamarreño, Carlos; Del Villar, Ignacio; Matías Maestro, Ignacio; Arregui San Martín, Francisco Javier; Ingeniería Eléctrica y Electrónica; Ingeniaritza Elektrikoa eta ElektronikoaThe fabrication and characterization of an optical fiber refractometer based on Lossy Mode Resonances (LMR) is presented. TiO2/ poly (sodium 4-styrenesulfonate) (PSS) coatings deposited on side-polished D-shaped optical fibers are used as LMR supporting coatings. LMRs are sensitive to the external medium refractive index and D-shaped optical fibers enable the observation of TE and TM LMR polarizations. These refractometers based on TE and TM LMR showed an average sensitivity of 2737 nm/RIU and 2893 nm/RIU respectively for a surrounding medium refractive index (SMRI) range from 1.35 to 1.41. This work also explores the utilization of previously described refractometers in the context of two common industrial applications such as the determination of the sugar content or °Brix in beverages and the salt concentration in sea water.