Analysis and description of HOLTIN service provision for AECG monitoring in complex indoor environments

dc.contributor.authorLed Ramos, Santiago
dc.contributor.authorAzpilicueta Fernández de las Heras, Leyre
dc.contributor.authorAguirre Gallego, Erik
dc.contributor.authorMartínez de Espronceda Cámara, Miguel
dc.contributor.authorSerrano Arriezu, Luis Javier
dc.contributor.authorFalcone Lanas, Francisco
dc.contributor.departmentIngeniería Eléctrica y Electrónicaes_ES
dc.contributor.departmentIngeniaritza Elektrikoa eta Elektronikoaeu
dc.date.accessioned2015-04-13T10:02:03Z
dc.date.available2015-04-13T10:02:03Z
dc.date.issued2013
dc.description.abstractIn this work, a novel ambulatory ECG monitoring device developed in-house called HOLTIN is analyzed when operating in complex indoor scenarios. The HOLTIN system is described, from the technological platform level to its functional model. In addition, by using in-house 3D ray launching simulation code, the wireless channel behavior, which enables ubiquitous operation, is performed. The effect of human body presence is taken into account by a novel simplified model embedded within the 3D Ray Launching code. Simulation as well as measurement results are presented, showing good agreement. These results may aid in the adequate deployment of this novel device to automate conventional medical processes, increasing the coverage radius and optimizing energy consumption.en
dc.description.sponsorshipProject ENEIDA TEC2010-21563-C02-01, funded by the Ministry of Economy and Competitiveness of Spain.en
dc.format.mimetypeapplication/pdfen
dc.identifier.doi10.3390/s130404947
dc.identifier.issn1424-8220 (electronic)
dc.identifier.urihttps://academica-e.unavarra.es/handle/2454/16944
dc.language.isoengen
dc.publisherMDPIen
dc.relation.ispartofSensors 2013, 13(4), 4947-4960es
dc.relation.projectIDinfo:eu-repo/grantAgreement/MICINN//TEC2010-21563-C02-01/ES/
dc.relation.publisherversionhttps://dx.doi.org/10.3390/s130404947
dc.rights© 2013 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license. en
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttps://creativecommons.org/licenses/by/3.0/
dc.subjectAmbulatory electrocardiogramen
dc.subjectU-Healthen
dc.subjectHOLTINen
dc.subject3D ray launchingen
dc.titleAnalysis and description of HOLTIN service provision for AECG monitoring in complex indoor environmentsen
dc.typeinfo:eu-repo/semantics/article
dc.type.versioninfo:eu-repo/semantics/publishedVersion
dspace.entity.typePublication
relation.isAuthorOfPublication017b7053-1fbc-4210-8f6c-07436ea32878
relation.isAuthorOfPublication00915558-0f9a-4e8e-a04c-8a7eaa1629da
relation.isAuthorOfPublicatione2f68555-d99f-47ce-89b3-6301be6d0ef7
relation.isAuthorOfPublicationc2e58b1c-202d-4a2e-8413-0ed7fa60e048
relation.isAuthorOfPublication21ab7bc6-f6ae-427d-938f-24452b396567
relation.isAuthorOfPublication69667b5c-e390-42d4-bc71-9f256c1b7b85
relation.isAuthorOfPublication.latestForDiscovery017b7053-1fbc-4210-8f6c-07436ea32878

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Led_Analysis.pdf
Size:
2.33 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed to upon submission
Description: