Computational fluid dynamics comparison of the upper airway velocity, pressure, and resistance in cats using an endotracheal tube or a supraglottic airway device

dc.contributor.authorZamora -Perarnau, Carla
dc.contributor.authorMalvè, Mauro
dc.contributor.authorFernández-Parra, Rocío
dc.contributor.departmentIngenieríaes_ES
dc.contributor.departmentIngeniaritzaeu
dc.date.accessioned2024-05-20T09:29:22Z
dc.date.available2024-05-20T09:29:22Z
dc.date.issued2023
dc.date.updated2024-05-20T09:17:46Z
dc.description.abstractIntoduction: In veterinary medicine, airway management of cats under general anesthesia is performed with an endotracheal tube (ETT) or supraglottic airway device (SGAD). This study aims to describe the use of computational fluid dynamics (CFD) to assess the velocities, pressures, and resistances of cats with ETT or SGAD. Methods: A geometrical reconstruction model of the device, trachea, and lobar bronchi was carried out from computed tomography (CT) scans that include the head, neck, and thorax. Twenty CT scans of cats under general anesthesia using ETT (n = 10) and SGAD (n = 10) were modeled and analyzed. An inspiratory flow of 2.4 L/min was imposed in each model and velocity (m/s), general and regional pressures (cmH2O) were computed. General resistance (cmH2O/L/min) was calculated using differential pressure differences between the device inlet and lobar bronchi. Additionally, regional resistances were calculated at the device¿s connection with the breathing circuit (region A), at the glottis area for the SGAD, and the area of the ETT exit (bevel) (region B) and the device itself (region C). Results: Recirculatory flow and high velocities were found at the ETT¿s bevel and at the glottis level in the SGAD group. The pressure gradient (¿p) was more enhanced in the ETT cases compared with the SGAD cases, where the pressure change was drastic. In region A, the ¿p was higher in the ETT group, while in regions B and C, it was higher in the SGAD group. The general resistance was not statistically significant between groups (p = 0.48). Higher resistances were found at the region A (p = <0.001) in the ETT group. In contrast, the resistance was higher in the SGAD cases at the region B (p = 0.001). Discussion: Overall, the provided CT-based CFD analysis demonstrated regional changes in airway pressure and resistance between ETT and SGAD during anesthetic flow conditions. Correct selection of the airway device size is recommended to avoid upper airway obstruction or changes in flow parameters.en
dc.description.sponsorshipMM and RF-P are supported by the grants PID2021-125731OB-C31 and PID2021-125731OB-C33, respectively, which are financed by the Spanish Ministry of Science and Innovation MCIN/AEI/10.13039/501100011033/ and FEDER ('A way to build Europe').en
dc.format.mimetypeapplication/pdfen
dc.identifier.citationZamora-Perarnau, C., Malvè, M., Fernández-Parra, R. (2023) Computational fluid dynamics comparison of the upper airway velocity, pressure, and resistance in cats using an endotracheal tube or a supraglottic airway device. Frontiers in Veterinary Science, 10, 1-48. https://doi.org/10.3389/fvets.2023.1183223.es_ES
dc.identifier.doi10.3389/fvets.2023.1183223
dc.identifier.issn2297-1769
dc.identifier.urihttps://academica-e.unavarra.es/handle/2454/48134
dc.language.isoengen
dc.publisherFrontiers Mediaen
dc.relation.ispartofFrontiers in Veterinary Science (2023), vol. 10en
dc.relation.projectIDinfo:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2021-2023/PID2021-125731OB-C31/ES/
dc.relation.projectIDinfo:eu-repo/grantAgreement///PID2021-125731OB-C33/
dc.relation.publisherversionhttps://doi.org/10.3389/fvets.2023.1183223
dc.rights© 2023 Zamora-Perarnau, Malvè and Fernández-Parra. This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY).en
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subjectIn silicoen
dc.subjectAirway managementen
dc.subjectV-gel®en
dc.subjectFelineen
dc.subjectGeneral anesthesiaen
dc.subjectETTen
dc.subjectFlowen
dc.titleComputational fluid dynamics comparison of the upper airway velocity, pressure, and resistance in cats using an endotracheal tube or a supraglottic airway deviceen
dc.typeinfo:eu-repo/semantics/article
dc.type.versioninfo:eu-repo/semantics/publishedVersion
dspace.entity.typePublication
relation.isAuthorOfPublicationaa62429b-fef0-4a2c-9d96-43dbf7f63675
relation.isAuthorOfPublication.latestForDiscoveryaa62429b-fef0-4a2c-9d96-43dbf7f63675

Files

Original bundle
Now showing 1 - 2 of 2
Loading...
Thumbnail Image
Name:
Zamora_ComputationalFluid.pdf
Size:
812.12 KB
Format:
Adobe Portable Document Format
Loading...
Thumbnail Image
Name:
Zamora_ComputationalFluid_MarCompl.pdf
Size:
1.73 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.78 KB
Format:
Item-specific license agreed to upon submission
Description: