Fiber optic ammonia sensor using Bromocresol Green pH indicator

dc.contributor.authorRodríguez Rodríguez, Adolfo Josué
dc.contributor.authorMay Arrioja, Daniel A.
dc.contributor.authorDomínguez Cruz, René
dc.contributor.authorRuiz Zamarreño, Carlos
dc.contributor.authorMatías Maestro, Ignacio
dc.contributor.authorArregui San Martín, Francisco Javier
dc.contributor.departmentIngeniería Eléctrica y Electrónicaes_ES
dc.contributor.departmentIngeniaritza Elektrikoa eta Elektronikoaeu
dc.date.accessioned2024-12-17T07:51:20Z
dc.date.available2024-12-17T07:51:20Z
dc.date.issued2014-12-15
dc.date.updated2024-12-17T07:45:22Z
dc.description.abstractWe report a fiber optic sensor for low levels of ammonia gas detection based on the use a Bromocresol Green (BCG) pH indicator attached to the optical fiber employing hydrophobic and gas permeable polyurethane film named Tecoflex® as attraping matrix. Highly reproducible and reversible fiber optical sensors have been achieved employing simple and short fabrication processes. The advantage for employ a BCG pH indicator is to take advantage of the basicity of ammonia exhibiting a wide spectral response (500 nm-750 nm) and shows recovery times of less than 15 s. The Tecoflex® film provides additional advantages to be measured to the sensitive area of the sensor, such as operation even in extremely dry environments, efficient transport and prevent leakage or detachment of the BCG pH indicator. The combination of the BCG pH indicator and Tecoflex® film provides a reliable and robust fiber optic ammonia gas sensor.en
dc.description.sponsorshipWe appreciate the support from the Consejo Nacional de Ciencia y Tecnología (CONACyT) under contract CB-2010/157866. This work was also supported by the Spanish Economy and Competitivity Ministry-FEDER TEC2010-17805
dc.format.mimetypeapplication/pdfen
dc.identifier.citationRodriguez Rodriguez, A. J., May-Arrioja, D. A., Dominguez Cruz, R. F., Zamarreno, C. R., Matias Maestro, R. I., Arregui San Martin, F. (2014) Fiber optic ammonia sensor using Bromocresol Green pH indicator. In IEEE Sensors Council (Ed.), IEEE Sensors 2014 Proceedings (pp. 1146-1149). IEEE. https://doi.org/10.1109/ICSENS.2014.6985210
dc.identifier.doi10.1109/ICSENS.2014.6985210
dc.identifier.isbn978-1-4799-0161-6
dc.identifier.urihttps://academica-e.unavarra.es/handle/2454/52763
dc.language.isoeng
dc.publisherIEEE
dc.relation.ispartofIn IEEE Sensors Council (Ed.). IEEE Sensors 2014 Proceedings. Piscataway: IEEE; 2014. p. 1146-1149
dc.relation.projectIDinfo:eu-repo/grantAgreement/MICINN//TEC2010-17805/ES/SENSORES DE FIBRA OPTICA BASADOS EN MATERIALES NANOESTRUCTURADOS/
dc.relation.publisherversionhttps://doi.org/10.1109/ICSENS.2014.6985210
dc.rights© 2014 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other work.
dc.rights.accessRightsinfo:eu-repo/semantics/closedAccess
dc.subjectOptical fiber sensoren
dc.subjectAmmonia sensoren
dc.subjectpH indicatoren
dc.titleFiber optic ammonia sensor using Bromocresol Green pH indicatoren
dc.typeinfo:eu-repo/semantics/conferenceObject
dc.type.versioninfo:eu-repo/semantics/acceptedVersion
dspace.entity.typePublication
relation.isAuthorOfPublicationf85c4fed-8804-4e02-b746-0855066291e3
relation.isAuthorOfPublicationbbb769e0-e56c-4b53-8e0b-cf33da20a35d
relation.isAuthorOfPublication90bd9817-d6cc-4907-ac5c-eb0d6317c3f7
relation.isAuthorOfPublication.latestForDiscoveryf85c4fed-8804-4e02-b746-0855066291e3

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Rodriguez_FiberOptic.pdf
Size:
372.42 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed to upon submission
Description: