CFD-based comparison study of a new flow diverting stent and commercially-available ones for the treatment of cerebral aneurysms

dc.contributor.authorCatalán Echeverría, Borja
dc.contributor.authorKelly, Michael E.
dc.contributor.authorPeeling, Lissa
dc.contributor.authorBergstrom, Donald
dc.contributor.authorChen, Xiongbiao
dc.contributor.authorMalvè, Mauro
dc.contributor.departmentIngenieríaes_ES
dc.contributor.departmentIngeniaritzaeu
dc.date.accessioned2019-11-12T13:50:14Z
dc.date.available2019-11-12T13:50:14Z
dc.date.issued2019
dc.description.abstractFlow-diverting stents (FDSs) show considerable promise for the treatment of cerebral aneurysms by diverting blood flow away from the aneurysmal sacs, however, post-treatment complications such as failure of occlusion and subarachnoid haemorrhaging remain and vary with the FDS used. Based on computational fluid dynamics (CFD), this study aimed to investigate the performance of a new biodegradable stent as compared to two metallic commercially available FDSs. CFD models were developed for an idealized cerebral artery with a sidewall aneurysmal sac treated by deploying the aforementioned stents of different porosities (90, 80, and <mml:semantics>70%</mml:semantics>) respectively. By using these models, the simulation and analysis were performed, with a focus on comparing the local hemodynamics or the blood flow in the stented arteries as compared to the one without the stent deployment. For the comparison, we computed and compared the flow velocity, wall shear stress (WSS) and pressure distributions, as well as the WSS related indices, all of which are of important parameters for studying the occlusion and potential rupture of the aneurysm. Our results illustrate that the WSS decreases within the aneurysmal sac on the treated arteries, which is more significant for the stents with lower porosity or finer mesh. Our results also show that the maximum WSS near the aneurysmal neck increases regardless of the stents used. In addition, the WSS related indices including the time-average WSS, oscillatory shear index and relative residence time show different distributions, depending on the FDSs. Together, we found that the finer mesh stents provide more flow reduction and smaller region characterized by high oscillatory shear index, while the new stent has a higher relative residence time.en
dc.description.sponsorshipThis research was funded by the Saskatchewan Health Research Foundation (SHRF Grant Reference #2784). M. Malve was supported by the Spanish Ministry of Education, Culture and Sport through the grant PRX17/00335 financed within the National Program 'Salvador de Madariaga'. The authors also acknowledge the support of the Spanish Ministry of Industry and Competitiveness via the research project DP12017-83259-R (AEI/FEDER, UE) and the Instituto de Salud Carlos III (ISCIII) through the CIBER-BBN initiative.en
dc.format.extent15 p.
dc.format.mimetypeapplication/pdfen
dc.identifier.doi10.3390/app9071341
dc.identifier.issn2076-3417 (Electronic)
dc.identifier.urihttps://academica-e.unavarra.es/handle/2454/35353
dc.language.isoengen
dc.publisherMDPIen
dc.relation.ispartofApplied Sciences, 2019, 9, 1341en
dc.relation.projectIDinfo:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2013-2016/DPI2017-83259-R/ES/
dc.relation.publisherversionhttps://doi.org/10.3390/app9071341
dc.rights© 2019 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.en
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttps://creativecommons.org/licenses/by/4.0/
dc.subjectCerebral aneurysmen
dc.subjectCFDen
dc.subjectFlow diverting stenten
dc.subjectMass flow reductionen
dc.subjectHemodynamicsen
dc.titleCFD-based comparison study of a new flow diverting stent and commercially-available ones for the treatment of cerebral aneurysmsen
dc.typeinfo:eu-repo/semantics/article
dc.type.versioninfo:eu-repo/semantics/publishedVersion
dspace.entity.typePublication
relation.isAuthorOfPublicationaa62429b-fef0-4a2c-9d96-43dbf7f63675
relation.isAuthorOfPublication.latestForDiscoveryaa62429b-fef0-4a2c-9d96-43dbf7f63675

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
2019060040_Catalan_CFDBasedComparison.pdf
Size:
4.14 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed to upon submission
Description: