Experimental and computational investigation of passive heat exchangers to enhance the performance of a geothermal thermoelectric generator

dc.contributor.authorPascual Lezaun, Nerea
dc.contributor.authorAlegría Cía, Patricia
dc.contributor.authorAraiz Vega, Miguel
dc.contributor.authorMartínez Echeverri, Álvaro
dc.contributor.authorAstrain Ulibarrena, David
dc.contributor.departmentIngenieríaes_ES
dc.contributor.departmentIngeniaritzaeu
dc.contributor.departmentInstitute of Smart Cities - ISCen
dc.date.accessioned2024-10-08T17:40:37Z
dc.date.available2024-10-08T17:40:37Z
dc.date.issued2024
dc.date.updated2024-10-08T17:17:40Z
dc.description.abstractThermoelectric devices hold significant promise for generating electricity from geothermal heat, enabling the powering of measuring equipment in remote locations without the need for moving parts. Nevertheless, most developed geothermal thermoelectric generators employ fans and pumps to enhance heat transfer, thereby compromising the robustness and reliability inherent to thermoelectricity. Furthermore, there is a lack of research on passive heat exchangers for geothermal thermoelectric generators, particularly in studying their operation under a wide range of meteorological conditions. Therefore, this paper conducts a comprehensive analysis of passive heat exchangers for the cold side of the generators. Phase-change-based heat exchangers differing in their length and fluid are studied experimentally, along with a fin dissipator. Additionally, the influence of wind velocity on heat transfer and mechanical requirements is further explored through a Computational Fluid Dynamics model. The most significant outcome is quantifying the impact of the design parameters and operational variables on the electrical production of the thermoelectric generator. Accordingly, this research aims to broaden the application of these generators to extreme environments, such as Deception Island in Antarctica. Under average operational conditions, generators incorporating 400 mm water heat pipes generate 0.95 W per thermoelectric module, while those incorporating heat pipes with methanol achieve an average of 0.70 W. Moreover, water and methanol-based systems produce 120% and 60% more power than generators using a fin dissipator. Nonetheless, for temperatures beyond -6.5 °C, water might freeze and the methanol-based heat exchangers become more suitable.en
dc.description.sponsorshipThe authors would like to acknowledge the support of the Spanish State Research Agency and EFEDER-UE, Spain for funding under the PID2021-124014OB-I00 research project.
dc.format.mimetypeapplication/pdfen
dc.identifier.citationPascual, N., Alegría, P., Araiz, M., Martínez, Á., Astrain, D. (2024) Experimental and computational investigation of passive heat exchangers to enhance the performance of a geothermal thermoelectric generator. Applied Thermal Engineering, 254, 1-14. https://doi.org/10.1016/j.applthermaleng.2024.123819.
dc.identifier.doi10.1016/j.applthermaleng.2024.123819
dc.identifier.issn1359-4311
dc.identifier.urihttps://academica-e.unavarra.es/handle/2454/52106
dc.language.isoeng
dc.publisherElsevier
dc.relation.ispartofApplied Thermal Engineering 254, 2024, 123819
dc.relation.projectIDinfo:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2021-2023/PID2021-124014OB-I00/ES/
dc.relation.publisherversionhttps://doi.org/10.1016/j.applthermaleng.2024.123819
dc.rights© 2024 The Author(s). Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license.
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subjectComputational modelen
dc.subjectGeothermal energyen
dc.subjectPassive heat exchangeren
dc.subjectThermal resistanceen
dc.subjectThermoelectric generatoren
dc.titleExperimental and computational investigation of passive heat exchangers to enhance the performance of a geothermal thermoelectric generatoren
dc.typeinfo:eu-repo/semantics/article
dc.type.versioninfo:eu-repo/semantics/publishedVersion
dspace.entity.typePublication
relation.isAuthorOfPublicationddef75f0-d2b5-4a3f-beb4-31b07172a310
relation.isAuthorOfPublication0e0cbc73-4797-4175-ad45-2ab1809d67fa
relation.isAuthorOfPublicationb191fa17-dc29-406f-891a-6fe13ccc325a
relation.isAuthorOfPublication1f41d3ad-c07b-4475-a762-109fe7c612d2
relation.isAuthorOfPublication5f626878-b8c6-4403-97ee-e14738ea30e2
relation.isAuthorOfPublication.latestForDiscovery5f626878-b8c6-4403-97ee-e14738ea30e2

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Pascual_Experimental.pdf
Size:
2.85 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed to upon submission
Description: