Design methodology for the frequency shift method of islanding prevention and analysis of its detection capability

dc.contributor.authorSanchis Gúrpide, Pablo
dc.contributor.authorMarroyo Palomo, Luis
dc.contributor.authorColoma, Javier
dc.contributor.departmentIngeniería Eléctrica y Electrónicaes_ES
dc.contributor.departmentIngeniaritza Elektrikoa eta Elektronikoaeu
dc.date.accessioned2023-05-10T07:47:42Z
dc.date.available2023-05-10T07:47:42Z
dc.date.issued2005
dc.date.updated2023-05-10T07:42:06Z
dc.description.abstractIslanding protection is one of the most important sources of discrepancy in gridconnected photovoltaic systems. Even when islanding is not very likely to happen, regulations demand the photovoltaic inverters to implement effective protection methods. Due to its several advantages, the frequency shift method of islanding prevention, commonly known as Sandia Frequency Shift, is one of the most important active methods. This method implements a positive feedback of the frequency that tends to move it outside the trip limits in case of islanding. The method shows a very high detection capability, which depends on both the values of the method parameters and the characteristics of the load that remains in the same power section after islanding. This paper develops a mathematical analysis of the Sandia Frequency Shift method and proposes a new methodology to design its parameters as a trade-off between the detection capability, which is evaluated as a function of the load characteristics, and the distortion that the method could introduce in the grid as a consequence of transitory frequency disturbances. The ability of this methodology to design the method parameters and achieve the highest detection capability is satisfactorily proved by means of both simulation and experimental results on a commercial photovoltaic inverter that implements the method once its parameters have been designed with the proposed methodology.en
dc.format.mimetypeapplication/pdfen
dc.identifier.citationSanchis, P., Marroyo, L., Coloma, J. (2005) Design methodology for the frequency shift method of islanding prevention and analysis of its detection capability. Progress in Photovoltaics: Research and Applications, 13(5), 409-428. https://doi.org/10.1002/pip.613.en
dc.identifier.doi10.1002/pip.613
dc.identifier.issn1062-7995
dc.identifier.urihttps://academica-e.unavarra.es/handle/2454/45277
dc.language.isoengen
dc.publisherWileyen
dc.relation.ispartofProgress in Photovoltaics: Research and Applications, 2005; 13:409–428en
dc.relation.publisherversionhttps://doi.org/10.1002/pip.613
dc.rights© 2005 John Wiley & Sons, Ltd.en
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.subjectGrid-connected photovoltaic invertersen
dc.subjectInvertersen
dc.subjectIslandingen
dc.subjectProtectionen
dc.subjectPhotovoltaic power systemsen
dc.titleDesign methodology for the frequency shift method of islanding prevention and analysis of its detection capabilityen
dc.typeinfo:eu-repo/semantics/article
dc.type.versioninfo:eu-repo/semantics/acceptedVersion
dspace.entity.typePublication
relation.isAuthorOfPublicationeb28ad46-ad2e-4415-a048-6c3f2fe48916
relation.isAuthorOfPublicationa68eb3e8-cf0e-4b2b-952b-d419a42a5f8c
relation.isAuthorOfPublication.latestForDiscoveryeb28ad46-ad2e-4415-a048-6c3f2fe48916

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Sanchis_DesignMethodology.pdf
Size:
590.47 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.78 KB
Format:
Item-specific license agreed to upon submission
Description: