Publication:
Estimation of radiofrequency power leakage from microwave ovens for dosimetric assessment at nonionizing radiation exposure levels

dc.contributor.authorLópez Iturri, Peio
dc.contributor.authorMiguel Bilbao, Silvia de
dc.contributor.authorAguirre Gallego, Erik
dc.contributor.authorAzpilicueta Fernández de las Heras, Leyre
dc.contributor.authorFalcone Lanas, Francisco
dc.contributor.authorRamos González, Victoria
dc.contributor.departmentIngeniería Eléctrica y Electrónicaes_ES
dc.contributor.departmentIngeniaritza Elektrikoa eta Elektronikoaeu
dc.date.accessioned2018-08-31T08:07:57Z
dc.date.available2018-08-31T08:07:57Z
dc.date.issued2015
dc.description.abstractThe electromagnetic field leakage levels of nonionizing radiation from a microwave oven have been estimated within a complex indoor scenario. By employing a hybrid simulation technique, based on coupling full wave simulation with an in-house developed deterministic 3D ray launching code, estimations of the observed electric field values can be obtained for the complete indoor scenario. The microwave oven can be modeled as a time- and frequency-dependent radiating source, in which leakage, basically from the microwave oven door, is propagated along the complete indoor scenario interacting with all of the elements present in it. Thismethod can be of aid in order to assess the impact of such devices on expected exposure levels, allowing adequate minimization strategies such as optimal location to be applied.en
dc.format.extent14 p.
dc.format.mimetypeapplication/pdfen
dc.identifier.doi10.1155/2015/603260
dc.identifier.issn2314-6133 (Print)
dc.identifier.issn2314-6141 (Electronic)
dc.identifier.urihttps://academica-e.unavarra.es/handle/2454/30348
dc.language.isoengen
dc.publisherHindawien
dc.relation.ispartofBiomed Research International, Volume 2015, Article ID 603260en
dc.relation.publisherversionhttps://doi.org/10.1155/2015/603260
dc.rights© 2015 Peio Lopez-Iturri et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.en
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttps://creativecommons.org/licenses/by/3.0/
dc.subjectMicrowave ovensen
dc.subjectRadiofrequency power leakageen
dc.subjectDosimetric assessmenten
dc.subjectNonionizing radiationen
dc.titleEstimation of radiofrequency power leakage from microwave ovens for dosimetric assessment at nonionizing radiation exposure levelsen
dc.typeinfo:eu-repo/semantics/article
dc.type.versioninfo:eu-repo/semantics/publishedVersionen
dc.type.versionVersión publicada / Argitaratu den bertsioaes
dspace.entity.typePublication
relation.isAuthorOfPublicationb0db43fb-1193-49ba-8372-f9d8277821a4
relation.isAuthorOfPublicatione2f68555-d99f-47ce-89b3-6301be6d0ef7
relation.isAuthorOfPublication00915558-0f9a-4e8e-a04c-8a7eaa1629da
relation.isAuthorOfPublication69667b5c-e390-42d4-bc71-9f256c1b7b85
relation.isAuthorOfPublication.latestForDiscoveryb0db43fb-1193-49ba-8372-f9d8277821a4

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
22_Lopez_Estimation Radiofrequency.pdf
Size:
4.86 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed to upon submission
Description: