Publication: Estimation of radiofrequency power leakage from microwave ovens for dosimetric assessment at nonionizing radiation exposure levels
dc.contributor.author | López Iturri, Peio | |
dc.contributor.author | Miguel Bilbao, Silvia de | |
dc.contributor.author | Aguirre Gallego, Erik | |
dc.contributor.author | Azpilicueta Fernández de las Heras, Leyre | |
dc.contributor.author | Falcone Lanas, Francisco Javier | |
dc.contributor.author | Ramos González, Victoria | |
dc.contributor.department | Ingeniería Eléctrica y Electrónica | es_ES |
dc.contributor.department | Ingeniaritza Elektrikoa eta Elektronikoa | eu |
dc.date.accessioned | 2018-08-31T08:07:57Z | |
dc.date.available | 2018-08-31T08:07:57Z | |
dc.date.issued | 2015 | |
dc.description.abstract | The electromagnetic field leakage levels of nonionizing radiation from a microwave oven have been estimated within a complex indoor scenario. By employing a hybrid simulation technique, based on coupling full wave simulation with an in-house developed deterministic 3D ray launching code, estimations of the observed electric field values can be obtained for the complete indoor scenario. The microwave oven can be modeled as a time- and frequency-dependent radiating source, in which leakage, basically from the microwave oven door, is propagated along the complete indoor scenario interacting with all of the elements present in it. Thismethod can be of aid in order to assess the impact of such devices on expected exposure levels, allowing adequate minimization strategies such as optimal location to be applied. | en |
dc.format.extent | 14 p. | |
dc.format.mimetype | application/pdf | en |
dc.identifier.doi | 10.1155/2015/603260 | |
dc.identifier.issn | 2314-6133 (Print) | |
dc.identifier.issn | 2314-6141 (Electronic) | |
dc.identifier.uri | https://academica-e.unavarra.es/handle/2454/30348 | |
dc.language.iso | eng | en |
dc.publisher | Hindawi | en |
dc.relation.ispartof | Biomed Research International, Volume 2015, Article ID 603260 | en |
dc.relation.publisherversion | https://doi.org/10.1155/2015/603260 | |
dc.rights | © 2015 Peio Lopez-Iturri et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. | en |
dc.rights.accessRights | info:eu-repo/semantics/openAccess | en |
dc.rights.accessRights | Acceso abierto / Sarbide irekia | es |
dc.rights.uri | https://creativecommons.org/licenses/by/3.0/ | |
dc.subject | Microwave ovens | en |
dc.subject | Radiofrequency power leakage | en |
dc.subject | Dosimetric assessment | en |
dc.subject | Nonionizing radiation | en |
dc.title | Estimation of radiofrequency power leakage from microwave ovens for dosimetric assessment at nonionizing radiation exposure levels | en |
dc.type | info:eu-repo/semantics/article | en |
dc.type | Artículo / Artikulua | es |
dc.type.version | info:eu-repo/semantics/publishedVersion | en |
dc.type.version | Versión publicada / Argitaratu den bertsioa | es |
dspace.entity.type | Publication | |
relation.isAuthorOfPublication | b0db43fb-1193-49ba-8372-f9d8277821a4 | |
relation.isAuthorOfPublication | e2f68555-d99f-47ce-89b3-6301be6d0ef7 | |
relation.isAuthorOfPublication | 00915558-0f9a-4e8e-a04c-8a7eaa1629da | |
relation.isAuthorOfPublication | 69667b5c-e390-42d4-bc71-9f256c1b7b85 | |
relation.isAuthorOfPublication.latestForDiscovery | b0db43fb-1193-49ba-8372-f9d8277821a4 |