Diseño, desarrollo y evaluación preliminar de un novedoso monitor de signos vitales llevable para vacunos

dc.contributor.authorQuispe Bonilla, Max David
dc.contributor.authorPoma Gutiérrez, Adolfo
dc.contributor.authorSerrano Arriezu, Luis Javier
dc.contributor.authorLed Ramos, Santiago
dc.contributor.authorQuispe Peña, Edgar
dc.contributor.departmentIngeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzareneu
dc.contributor.departmentInstitute of Smart Cities - ISCen
dc.contributor.departmentIngeniería Eléctrica, Electrónica y de Comunicaciónes_ES
dc.date.accessioned2019-11-12T13:50:15Z
dc.date.available2019-11-12T13:50:15Z
dc.date.issued2019
dc.description.abstractEl monitoreo de los diferentes signos vitales en vacunos tiene importancia desde el punto de vista productivo, sanitario y de bienestar animal; sin embargo, existen pocos equipos que tengan el potencial de uso a nivel de campo y que no sean invasivos. Por tal motivo se llevó a cabo el presente trabajo con la finalidad de diseñar, construir y evaluar el uso de un pequeño MOnitor de SIgnos VItales LLevable (MOSIVILLe), que sea capaz de capturar las señales vitales en vacunos bajo condiciones de campo. El diseño y desarrollo del MOSIVILLe se realizó en Lima, Perú, entre enero y octubre de 2017 y la evaluación en campo se realizó en Chota, Perú, utilizando 11 vaquillas entre noviembre de 2017 y febrero de 2018. Con el uso del MOSIVILLe se obtuvieron las señales vitales de vacunos, reconociéndose las ondas P, Q, R, S, T, complejo QRS e intervalo RR del electrocardiograma que condujeron a obtener la frecuencia cardiaca (FC). Adicionalmente, se obtuvo la temperatura de la piel (T°P) y la señal de ventilación con los picos de inhalación, exhalación, tiempo de inspiración y tiempo de espiración que determinan la frecuencia respiratoria (FR). El MOSIVILLe usado en vacunos en condiciones de campo permitió obtener una FC de 70.83±1.47, FR de 25.24±1.64 y una T°P de 31.52±0.40 (promedio ± error estándar), valores que se encuentran en concordancia con la literatura. Se concluye que el MOSIVILLe es una alternativa importante para obtener diversos signos vitales en vacunos bajo condiciones de campo.es_ES
dc.description.abstractThe monitoring of various vital signs in cattle is important from the point of view of production, health and animal welfare; however, there are few devices that have the potential to be used at the field level and that are not invasive. For this reason, the present work was carried out with the purpose of designing, constructing and evaluating the use of wearable vital signs monitor (MOSIVILLe), which is capable of capturing the vital signs in cattle under field conditions. The design and development of MOSIVILLe was carried out in Lima, Peru, between January and October 2017 and the field evaluation was carried out in Chota, Peru, using 11 heifers between November 2017 and February 2018. The vital signs of cattle were obtained with the MOSIVILLe, recognizing the P, Q, R, S, T waves, QRS complex and RR interval of the electrocardiogram that led to obtain the heart rate (HR). Additionally, the skin temperature (T degrees S) and the ventilation signal were obtained with the peaks of inhalation, exhalation, inspiration time and expiration time that determine the respiratory frequency (RF). MOSIVILLe used in cattle in field conditions allowed to obtain an HR of 70.83 +/- 1.47, RF of 25.24 +/- 1.64 and a T degrees S of 31.52 +/- 0.40 (mean +/- standard error), values that agree with the literature. It is concluded that MOSIVILLe is an important alternative to obtain various vital signs in cattle under field conditions.en
dc.format.extent14 p.
dc.format.mimetypeapplication/pdfen
dc.identifier.doi10.15381/rivep.v30i1.15684
dc.identifier.issn1682-3419
dc.identifier.urihttps://academica-e.unavarra.es/handle/2454/35356
dc.language.isospaen
dc.publisherUniversidad Nacional Mayor de San Marcos (Perú)en
dc.relation.ispartofRevista de Investigaciones Veterinarias del Perú, 2019; 30(1): 74-87en
dc.relation.publisherversionhttps://doi.org/10.15381/rivep.v30i1.15684
dc.rightsLicencia Creative Commons Atribución-NoComercial-CompartirIgual 4.0 Internacionalen
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttps://creativecommons.org/licenses/by-nc-sa/4.0/deed.es/
dc.subjectElectrocardiogramaes_ES
dc.subjectECGes_ES
dc.subjectRespiraciónes_ES
dc.subjectTemperatura de la pieles_ES
dc.subjectEquipo llevablees_ES
dc.subjectElectrocardiogramen
dc.subjectECGen
dc.subjectBreathingen
dc.subjectSkin temperatureen
dc.subjectWearable medical deviceen
dc.titleDiseño, desarrollo y evaluación preliminar de un novedoso monitor de signos vitales llevable para vacunoses_ES
dc.title.alternativeDesign, development and preliminary evaluation of a new wearable vital signs monitor for cattleen
dc.typeinfo:eu-repo/semantics/article
dc.type.versioninfo:eu-repo/semantics/publishedVersion
dspace.entity.typePublication
relation.isAuthorOfPublicationc69a5f75-e455-4367-b641-e335451fac03
relation.isAuthorOfPublication21ab7bc6-f6ae-427d-938f-24452b396567
relation.isAuthorOfPublication017b7053-1fbc-4210-8f6c-07436ea32878
relation.isAuthorOfPublication.latestForDiscovery21ab7bc6-f6ae-427d-938f-24452b396567

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
2019060062_Quispe_DisenoDesarrollo.pdf
Size:
1.15 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed to upon submission
Description: