Optimal combination of an air-to-air thermoelectric heat pump with a heat recovery system to HVAC a passive house dwelling
Date
Director
Publisher
Project identifier
Impacto
Abstract
The main objective of this research is to propose a HVAC system for an 80–100 m2 passive house dwelling based on a thermoelectric air-to-air heat pump combined with a heat recovery unit. The computational parametric investigation demonstrates that the integration of the heat recovery unit significantly improves the coefficient of performance of the heat pump: 2–3 times for partial load operation and 12.5 % for maximum load. Moreover, the number of required modules to reach the maximum performance is at least 5 times lower.
A second analysis assesses its seasonal heating performance in three climates as stated by the energy labeling Directive 2010/30/EU. The optimum number of thermoelectric modules in all cases is close to 15, regardless of the climate. This 15-modules thermoelectric heat pump provides a maximum heating capacity of 2500 W and 405 W for cooling, which compensates the typical internal heat gains and the transmission heat flux through the building envelope and the ventilation in the passive house dwelling. Finally, the analysis reveals that, in order to increase this cooling capacity, it is more convenient the improvement of the heat exchangers between the thermoelectric modules and the cooling air stream, rather than increasing the number of modules.
Description
Keywords
Department
Faculty/School
Degree
Doctorate program
item.page.cita
item.page.rights
© 2022 Elsevier Ltd. This manuscript version is made available under the CC-BY-NC-ND 4.0
Los documentos de Academica-e están protegidos por derechos de autor con todos los derechos reservados, a no ser que se indique lo contrario.