Publication:
On the stability of advanced power electronic converters: the Generalized Bode Criterion

dc.contributor.authorLumbreras Magallón, David
dc.contributor.authorBarrios Rípodas, Ernesto
dc.contributor.authorUrtasun Erburu, Andoni
dc.contributor.authorUrsúa Rubio, Alfredo
dc.contributor.authorMarroyo Palomo, Luis
dc.contributor.authorSanchis Gúrpide, Pablo
dc.contributor.departmentIngeniería Eléctrica, Electrónica y de Comunicaciónes_ES
dc.contributor.departmentIngeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzareneu
dc.contributor.funderUniversidad Pública de Navarra / Nafarroako Unibertsitate Publikoaes
dc.date.accessioned2019-06-26T08:10:36Z
dc.date.available2019-12-04T00:00:15Z
dc.date.issued2019
dc.description.abstractA key factor in the design of power electronic converters is the development of control systems and, in particular, the determination of their stability. Due to ease of application, the Bode criteria are currently the most commonly used stability criteria, both with regard to its classic version and to the subsequent revisions proposed in the literature. However, as these criteria have a limited range of applicability, on occasions it is necessary to resort to other universally applicable criteria such as the Nyquist criterion. Unlike Bode, the Nyquist criterion can always be applied, although its use considerably complicates the tuning of the controller. This paper proposes a new stability criterion, called Generalized Bode Criterion, which is based on the Nyquist criterion and, therefore, always applicable, but calculated from both the Bode diagram and the 0 Hz phase of the open-loop transfer function, thus making the criterion easy to be applied. This way, the proposed criterion combines the advantages of Nyquist and Bode criteria and provides an interesting and useful tool to help in the controller design process. The validation of the criterion is made on a voltage control loop for a stand-alone PV system through simulation and experimental tests made on a voltage control loop for a stand-alone PV system including a battery, a boost converter, an inverter and an ac load. The tests are also used to show the limitations of the classic Bode criterion and its revisions to correctly determine the stability of complex systems. IEEEen
dc.description.sponsorshipThis work was supported in part by the Spanish State Research Agency (AEI) and FEDER-UE underGrant DPI2016-80641-R and Grant DPI2016-80642-R, in part by the Public University of Navarre through a doctoral scholarship, and in part by the Ingeteam Power Technologyen
dc.embargo.lift2019-12-04
dc.embargo.terms2019-12-04
dc.format.extent16 p.
dc.format.mimetypeapplication/pdfen
dc.identifier.doi10.1109/TPEL.2018.2884892
dc.identifier.issn0885-8993
dc.identifier.urihttps://academica-e.unavarra.es/handle/2454/33511
dc.language.isoengen
dc.publisherIEEEen
dc.relation.ispartofIEEE Transactions on Power Electronics, vol. 34, no. 9, September 2019en
dc.relation.projectIDinfo:eu-repo/grantAgreement/ES/1PE/DPI2016-80641-Ren
dc.relation.projectIDinfo:eu-repo/grantAgreement/ES/1PE/DPI2016-80642-Ren
dc.relation.publisherversionhttps://doi.org/10.1109/TPEL.2018.2884892
dc.rights© 2019 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other work.en
dc.rights.accessRightsinfo:eu-repo/semantics/openAccessen
dc.rights.accessRightsAcceso abierto / Sarbide irekiaes
dc.subjectControl systemsen
dc.subjectFrequency domain analysisen
dc.subjectNyquisten
dc.subjectStabilityen
dc.subjectStability criteriaen
dc.titleOn the stability of advanced power electronic converters: the Generalized Bode Criterionen
dc.typeinfo:eu-repo/semantics/articleen
dc.typeArtículo / Artikuluaes
dc.type.versioninfo:eu-repo/semantics/acceptedVersionen
dc.type.versionVersión aceptada / Onetsi den bertsioaes
dspace.entity.typePublication
relation.isAuthorOfPublicationa7f593ce-efb4-4460-a3d4-62cf18f1704d
relation.isAuthorOfPublication85979913-47c3-472f-804b-a21e6e1204ec
relation.isAuthorOfPublication7cedc40b-6b94-46fc-951c-536223530127
relation.isAuthorOfPublicationb0612ced-717d-455f-b411-6b3d3affcde0
relation.isAuthorOfPublicationa68eb3e8-cf0e-4b2b-952b-d419a42a5f8c
relation.isAuthorOfPublicationeb28ad46-ad2e-4415-a048-6c3f2fe48916
relation.isAuthorOfPublication.latestForDiscoverya7f593ce-efb4-4460-a3d4-62cf18f1704d

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
240_Lumbreras_StabilityAdvanced.pdf
Size:
1.8 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed to upon submission
Description: