Direct analysis of aluminum alloys by CSigma laser-induced breakdown spectroscopy

dc.contributor.authorAragón Garbizu, Carlos
dc.contributor.authorAguilera Andoaga, José Antonio
dc.contributor.departmentZientziakeu
dc.contributor.departmentInstitute for Advanced Materials and Mathematics - INAMAT2en
dc.contributor.departmentCienciases_ES
dc.date.accessioned2020-11-11T10:24:54Z
dc.date.available2020-11-11T10:24:54Z
dc.date.issued2018
dc.description.abstractWe report the application of CSigma laser-induced breakdown spectroscopy (Cσ-LIBS) to quantitative analysis of aluminum alloys without sample preparation. Cσ-LIBS simplifies strongly the conventional calibration procedure of LIBS, replacing it with a characterization stage performed from the spectrum of a single standard sample. The aim of this work has been to provide a complete evaluation of the use of Cσ-LIBS for direct analysis by obtaining its figures of merit, including precision and limits of detection. Ten elements (Si, Fe, Cu, Mn, Mg, Cr, Ni, Zn, Ti and Ca) are determined in a set of six certified samples with a wide range of concentrations, from percent down to μg/g levels. The average precision is 8.0% for concentrations higher than 0.1 wt% and 13% for concentrations between 0.1 wt% and 0.01 wt%. The limits of detection are in the range 1.4–9.7 μg/g.en
dc.description.sponsorshipThis work has been supported by the project FIS2014-54285-P of the Spanish Ministerio de Economía y Competitividad.en
dc.format.extent8 p.
dc.format.mimetypeapplication/pdfen
dc.identifier.doi10.1016/j.aca.2018.01.019
dc.identifier.issn0003-2670
dc.identifier.urihttps://academica-e.unavarra.es/handle/2454/38586
dc.language.isoengen
dc.publisherElsevieren
dc.relation.ispartofAnalytica Chimica Acta, 2018, 1009, 12-19en
dc.relation.projectIDinfo:eu-repo/grantAgreement/MINECO//FIS2014-54285-P/ES/
dc.relation.publisherversionhttps://doi.org/10.1016/j.aca.2018.01.019
dc.rights© 2018 The Authors. This is an open access article under the CC BY-NC-ND license.en
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subjectLaser-induced breakdown spectroscopyen
dc.subjectLIBSen
dc.subjectCSigma LIBSen
dc.subjectQuantitative analysisen
dc.subjectStandardless analysisen
dc.subjectAluminum alloysen
dc.titleDirect analysis of aluminum alloys by CSigma laser-induced breakdown spectroscopyen
dc.typeinfo:eu-repo/semantics/article
dc.type.versioninfo:eu-repo/semantics/publishedVersion
dspace.entity.typePublication
relation.isAuthorOfPublicationbbfae432-95c0-4c04-890b-0006460d2d6f
relation.isAuthorOfPublication5e134e4e-f471-4dfa-8db2-db3a05485264
relation.isAuthorOfPublication.latestForDiscoverybbfae432-95c0-4c04-890b-0006460d2d6f

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
05_Aragon_DirectAnaysis.pdf
Size:
575.01 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed to upon submission
Description: