López Aldaba, Aitor

Loading...
Profile Picture

Email Address

Birth Date

Job Title

Last Name

López Aldaba

First Name

Aitor

person.page.departamento

Ingeniería Eléctrica y Electrónica

person.page.instituteName

ORCID

person.page.observainves

person.page.upna

Name

Search Results

Now showing 1 - 10 of 23
  • PublicationOpen Access
    Simultaneous measurement of humidity and vibration based on a microwire sensor system using Fast Fourier Transform technique
    (IEEE, 2016) Rota Rodrigo, Sergio; López Aldaba, Aitor; Pérez Herrera, Rosa Ana; López Bautista, María del Carmen; López-Amo Sáinz, Manuel; Ingeniería Eléctrica y Electrónica; Ingeniaritza Elektrikoa eta Elektronikoa
    This paper presents a new sensor system for vibration and relative humidity measurements based on its interaction with the evanescent field of a microwire. The interrogation of the sensing head is carried out by monitoring the fast Fourier transform (FFT) phase of one of the FFT peaks of the microwire transmission signal. This technique is not dependent of the signal amplitude and also eludes the requisite of tracking the wavelength evolution in the spectrum, which can be a handicap when there are multiple interference frequency components with different sensitivities. The point sensor is able to measure a wide humidity range (20%-70% relative humidity) with a maximum sensitivity reached of 0.14πrad/% relative humidity. This microwire sensor is also operated within a frequency range from 320 to 1300 Hz with a sensitivity of around 0.0051 nm -1 /Hz. Finally, due to the system uses an optical interrogator as unique active element, the system presents a cost-effective feature.
  • PublicationOpen Access
    Characterization of a hybrid Fabry-Pérot Cavity based on a four-bridge double-Y-shape-core microstructured fiber
    (SPIE, 2014-06-02) Rodrigues Pinto, Ana Margarida; López Aldaba, Aitor; López-Amo Sáinz, Manuel; Frazão, Orlando; Santos, José Luís; Baptista, José Manuel; Baierl, Hardy; Auguste, Jean-Louis; Jamier, Raphael; Roy, Philippe; Ingeniería Eléctrica y Electrónica; Ingeniaritza Elektrikoa eta Elektronikoa; Institute of Smart Cities - ISC
    In this work, a hybrid Fabry-Perot interferometer based on a novel four-bridge microstructured fiber is presented and characterized. The characterization of this cavity is performed in the L-band using two different instruments: an optical spectrum analyzer and an optical backscatter reflectometer. The Fabry-Perot output signal presents linear variation with temperature changes (sensitivity 9.8-11.9 pm/ºC), variation with the polarization states of light and high stability.
  • PublicationOpen Access
    Enhancement of the sensitivity of a volatile organic compounds MOF sensor by means of its structure
    (MDPI, 2019) López Torres, Diego; López Aldaba, Aitor; Elosúa Aguado, César; Auguste, Jean-Louis; Jamier, Raphael; Roy, Philippe; López-Amo Sáinz, Manuel; Arregui San Martín, Francisco Javier; Ingeniería Eléctrica y Electrónica; Ingeniaritza Elektrikoa eta Elektronikoa; Institute of Smart Cities - ISC; Universidad Pública de Navarra / Nafarroako Unibertsitate Publikoa
    In this paper, we experimentally compare several core structures of Microstructured Optical Fibers (MOFs) for low-finesse Fabry-Pérot (FP) sensors. These sensors are designed for Volatile Organic Compounds (VOCs) measurements. We deposit Indium Tin Oxide (ITO) thin films by sputtering on the MOFs and different optical phase responses of the FP were measured for saturated atmospheres of ethanol. The sensitivity of the developed sensors is demonstrated to depend on the geometry and the dimensions of the MOF-cores. The sensors show recovery times under 100 s and the baselines are fully recovered after exposure to VOC.
  • PublicationOpen Access
    SnO2-MOF-Fabry-Pérot humidity optical sensor system based on Fast Fourier transform technique
    (SPIE, 2016) López Aldaba, Aitor; López Torres, Diego; Ascorbe Muruzabal, Joaquín; Rota Rodrigo, Sergio; Elosúa Aguado, César; López-Amo Sáinz, Manuel; Arregui San Martín, Francisco Javier; Corres Sanz, Jesús María; Auguste, Jean-Louis; Jamier, Raphael; Roy, Philippe; Ingeniaritza Elektrikoa eta Elektronikoa; Institute of Smart Cities - ISC; Ingeniería Eléctrica y Electrónica
    In this paper, a new sensor system for relative humidity measurements based on a SnO2 sputtering deposition on a microstructured optical fiber (MOF) low-finesse Fabry-Pérot (FP) sensing head is presented and characterized. The interrogation of the sensing head is carried out by monitoring the Fast Fourier Transform phase variations of the FP interference frequency. This method is low-sensitive to signal amplitude variations and also avoids the necessity of tracking the evolution of peaks and valleys in the spectrum. The sensor is operated within a wide humidity range (20%-90% relative humidity) with a maximum sensitivity achieved of 0.14rad/%. The measurement method uses a commercial optical interrogator as the only active element, this compact solution allows real time analysis of the data.
  • PublicationOpen Access
    Interferometric vs wavelength selective optical fiber sensors for cryogenic temperature measurements
    (SPIE, 2017) Miguel Soto, Verónica de; Leandro González, Daniel; López Aldaba, Aitor; Beato López, Juan Jesús; Pérez de Landazábal Berganzo, José Ignacio; Auguste, Jean-Louis; Jamier, Raphael; Roy, Philippe; López-Amo Sáinz, Manuel; Ingeniaritza Elektrikoa eta Elektronikoa; Fisika; Institute for Advanced Materials and Mathematics - INAMAT2; Ingeniería Eléctrica y Electrónica; Física
    In this work, a preliminary study of the behavior of two different interferometric fiber optic sensors and two different wavelength selective fiber optic sensors is performed. A photonic cristal fiber Fabry-Pérot interferometer, a Sagnac interferometer, a commercial fiber Bragg grating (FBG) and a π-phase shifted fiber Bragg grating interrogated in a random distributed feedback fiber laser are analyzed. A comparison of their sensitivities and resolutions is carried out to analyze their performance as sensors for cryogenic temperatures, taking into account their advantages and drawbacks.
  • PublicationOpen Access
    Microstructured optical fiber sensor for soil moisture measurements
    (Optical Society of America, 2018) López Aldaba, Aitor; López Torres, Diego; Campo-Bescós, Miguel; López Rodríguez, José Javier; Yerro Lizarazu, David; Elosúa Aguado, César; Arregui San Martín, Francisco Javier; Auguste, Jean-Louis; Jamier, Raphael; Roy, Philippe; López-Amo Sáinz, Manuel; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren; Ingeniaritza; Institute of Smart Cities - ISC; Ingeniería Eléctrica, Electrónica y de Comunicación; Ingeniería
    A discrete sensor based on a Sn0₂-FP (Fabry-Pérot) cavity is presented and characterized in real soil conditions. Results are compared, for the first time to our knowledge, with a commercial capacitive sensor and gravimetric measurements.
  • PublicationOpen Access
    Optical power-based interrogation of plasmonic tilted fiber Bragg grating biosensors
    (SPIE, 2017) González Vila, Á.; López Aldaba, Aitor; Kinet, D.; Mégret, P.; López-Amo Sáinz, Manuel; Caucheteur, C.; Ingeniería Eléctrica y Electrónica; Ingeniaritza Elektrikoa eta Elektronikoa
    Two interrogation techniques for plasmonic tilted fiber Bragg grating sensors are reported and experimentally tested. Typical interrogation methods are usually based on tracking the wavelength shift of the most sensitive cladding mode, but for biosensing applications, spectrometer-based methods can be replaced by more efficient solutions. The proposed techniques thus rely on the measurement of the induced changes in optical power. The first one consists of a properly polarized tunable laser source set to emit at the wavelength of the sensor most sensitive mode and an optical power meter to measure the transmitted response. For the second method, a uniform fiber Bragg grating is photo-inscribed beyond the sensor in such a way that its central wavelength matches the sensor most sensitive mode, acting as an optical filter. Using a LED source, light reflected backwards by this grating is partially attenuated when passing through the sensor due to plasmon wave excitation and the power changes are quantified once again with an optical power meter. A performance analysis of the techniques is carried out and they both result competitive interrogation solutions. The work thus focuses on the development of cost-effective alternatives for monitoring this kind of biosensors in practical situations.
  • PublicationOpen Access
    Sensitivity optimization of a microstructured optical fiber ammonia gas sensor by means of tuning the thickness of a metal oxide nano-coating
    (IEEE, 2019) López Torres, Diego; López Aldaba, Aitor; Elosúa Aguado, César; Auguste, Jean-Louis; Jamier, Raphael; Roy, Philippe; López-Amo Sáinz, Manuel; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren; Institute of Smart Cities - ISC; Ingeniería Eléctrica, Electrónica y de Comunicación; Universidad Pública de Navarra / Nafarroako Unibertsitate Publikoa
    In this paper, the influence of the thickness of metallic-oxide coatings, ITO, and SnO2 on the sensitivity of a microstructured optical fiber Fabry–Pérot (FP) has been studied with the aim of developing ammonia gas fiber optic sensors. Also, the distribution of the optical power that can be coupled to the metallic-oxide sensing films is investigated in order to understand how the sensor’s sensitivity can be improved; the thickness of the coatings plays a relevant role on the sensitivity and response time. Films with thicknesses between 200 and 850 nm were experimentally examined resulting in an optimal thickness of 625 nm for a SnO2 film. The behavior of the sensors toward different concentrations of ammonia gas from 10 to 130 ppm was analyzed by measuring the phase shifts of the reflected signal using the fast Fourier transform of its optical spectrum. The registered response/recovery times of this sensor are below 90 s.
  • PublicationOpen Access
    Polyaniline deposition on tilted fiber Bragg grating for pH sensing
    (SPIE, 2017) López Aldaba, Aitor; González Vila, Á.; Debliquy, M.; López-Amo Sáinz, Manuel; Caucheteur, C.; Lahem, D.; Ingeniería Eléctrica y Electrónica; Ingeniaritza Elektrikoa eta Elektronikoa
    In this paper, we present the results of a new pH sensor based on a polyaniline (PAni) coating on the surface of a tilted fiber Bragg grating. The pH-sensitive PAni was deposited by in situ chemical oxidative polymerization. The performance of the fabricated pH sensor was tested and the obtained pH values were compared with the results obtained using a pH meter device. It was found that the sensor exhibits response to pH changes in the range of 2-12, achieving a sensitivity of 46 pm/pH with a maximum error due to the hysteresis effect of ±1.14 pH. The main advantages of this PAni-TFBG pH sensor are biochemical compatibility, temperature independence, long-term stability and remote real-time multipoint sensing features. This type of sensor could be used for biochemical applications, pipeline corrosion monitoring or remote-multipoint measurements.
  • PublicationOpen Access
    Real time measuring system of multiple chemical parameters using microstructured optical fibers based sensors
    (IEEE, 2018) López Aldaba, Aitor; López Torres, Diego; Elosúa Aguado, César; Arregui San Martín, Francisco Javier; Auguste, Jean-Louis; Jamier, Raphael; Roy, Philippe; López-Amo Sáinz, Manuel; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren; Institute of Smart Cities - ISC; Ingeniería Eléctrica, Electrónica y de Comunicación
    In this paper, a multiplexing system for simultaneous interrogation of optical fiber sensors which measure different parameters is presented and validated. The whole system has been tested with 6 different sensing heads with different purposes: one temperature sensing head, two relative humidity sensors and three VOCs leak sensors; all of them based on microstructured optical fibers. The interrogation system uses the FFT technique to isolate each sensor's interference, enabling their simultaneous interrogation. The system interrogates all the sensors at frequencies up to 1 KHz, showing a good performance of each measurement without crosstalk between sensors. The developed system is independent of the sensors' purpose or of the multiplexing topology.