Del Villar, Ignacio
Loading...
Email Address
person.page.identifierURI
Birth Date
Job Title
Last Name
Del Villar
First Name
Ignacio
person.page.departamento
Ingeniería Eléctrica, Electrónica y de Comunicación
person.page.instituteName
ISC. Institute of Smart Cities
ORCID
person.page.observainves
person.page.upna
Name
- Publications
- item.page.relationships.isAdvisorOfPublication
- item.page.relationships.isAdvisorTFEOfPublication
- item.page.relationships.isAuthorMDOfPublication
145 results
Search Results
Now showing 1 - 10 of 145
Publication Open Access Fabrication of long period gratings by periodically removing the coating of cladding-etched single mode optical fiber towards optical fiber sensor development(MDPI, 2018) Ascorbe Muruzabal, Joaquín; Corres Sanz, Jesús María; Del Villar, Ignacio; Matías Maestro, Ignacio; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren; Institute of Smart Cities - ISC; Ingeniería Eléctrica, Electrónica y de Comunicación; Gobierno de Navarra / Nafarroako Gobernua, 2017/PI044Here, we present a novel method to fabricate long period gratings using standard single mode optical fibers (SMF). These optical devices were fabricated in a three-step process, which consisted of etching the SMF, then coating it with a thin-film and, the final step, which involved removing sections of the coating periodically by laser ablation. Tin dioxide was chosen as the material for this study and it was sputtered using a pulsed DC sputtering system. Theoretical simulations were performed in order to select the appropriate parameters for the experiments. The responses of two different devices to different external refractive indices was studied, and the maximum sensitivity obtained was 6430 nm/RIU for external refractive indices ranging from 1.37 to 1.39.Publication Open Access Low cutoff wavelength etched SMS structures towards verification of the quality of automotive antifreeze(IEEE, 2020) Rodríguez Rodríguez, Wenceslao Eduardo; Rodríguez Rodríguez, Adolfo Josué; Ruiz Zamarreño, Carlos; Del Villar, Ignacio; Zúñiga Alanís, Manuel; Ingeniería Eléctrica, Electrónica y de Comunicación; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren; Gobierno de Navarra / Nafarroako Gobernua, 2019 904 116; Universidad Pública de Navarra / Nafarroako Unibertsitate Publikoa, PJUPNA26Optical fiber single mode-multimode-single mode (SMS) structures can be used as wavelength detection-based sensors. In this work, we focus on the performance at short wavelengths, where optical sources and detectors are less expensive. Here, a self-image band with a high transmission power is monitored in this short-wavelength range. In addition, the diameter and the length of the SMS structure have been optimized in order to improve the sensitivity of the device. In this sense, a maximum refractive index sensitivity of 305 nm/RIU was achieved by an etched SMS with a diameter of 34μ m. Furthermore, the obtained devices were used for testing the quality of automotive coolant and antifreeze liquid.Publication Open Access Sensitivity enhancement by diameter reduction in low cutoff wavelength single-mode multimode singlemode (SMS) fiber sensors(IEEE, 2017) Goñi Carnicero, Jaime; Del Villar, Ignacio; Arregui San Martín, Francisco Javier; Matías Maestro, Ignacio; Ingeniería Eléctrica y Electrónica; Ingeniaritza Elektrikoa eta ElektronikoaTwo different low cutoff wavelength single-mode fibers were used in single-mode multimode single-mode (SMS) configuration with the aim of designing sensors operating at short wavelengths, where optical sources and spectrometers are less expensive than in telecommunications bands. The diameter of the SMS structure was reduced with an etching process based on hydrofluoric acid immersion. The results prove that the devices can operate at wavelength ranges from 600 to 1200 nm and that multiple peaks can be obtained, each one with a different sensitivity that is proportional to the wavelength. Moreover, a fivefold increase in sensitivity to refractive index can be obtained. This high sensitivity indicates the possibility to apply this simple and cost-effective device in other applications such as biosensors or chemical sensors.Publication Open Access Asymmetrically and symmetrically coated tapered optical fiber for sensing applications(SPIE, 2015) Del Villar, Ignacio; Socorro Leránoz, Abián Bentor; Corres Sanz, Jesús María; Arregui San Martín, Francisco Javier; Matías Maestro, Ignacio; Ingeniería Eléctrica y Electrónica; Ingeniaritza Elektrikoa eta ElektronikoaThe deposition of a non-metallic thin-film in a symmetrically coated tapered optical fiber leads to the generation of resonances due to guidance of a mode in the thin-film. At certain conditions, the resonances overlap each other, which can be avoided with an asymmetric coated tapered optical fiber, which permits to obtain resonances for TM and TE polarization separately. Numerical results showing the sensitivity to coating thickness and surrounding medium refractive index are also presented for both polarizations.Publication Open Access Mode transitions and thickness measurements during deposition of nanoscale TiO2 coatings on tilted fiber Bragg gratings(IEEE, 2022) Imas González, José Javier; Albert, Jacques; Del Villar, Ignacio; Ozcariz Celaya, Aritz; Ruiz Zamarreño, Carlos; Matías Maestro, Ignacio; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren; Institute of Smart Cities - ISC; Ingeniería Eléctrica, Electrónica y de ComunicaciónThe mode transition is a phenomenon observed in thin film coated long period fiber gratings (LPGs) and singlemode multimode single-mode (SMS) fibers for certain values of the coating thickness and refractive index, resulting in increased sensitivity for sensing applications. It is shown here that mode transitions occur simultaneously for a large number of mode resonances in the transmission spectra of tilted fiber Bragg gratings (TFBG) measured during the deposition of ~350nm thick TiO2 coatings by Atomic Layer Deposition (ALD). In TFBGs, the mode transition shows up as an acceleration of the resonance wavelength shift vs thickness, but without fading of the resonance amplitude. Furthermore, the results show that the mode transition for cladding modes with predominantly “TE” polarization at the cladding boundary is significantly sharper than that of predominantly “TM” polarized modes and that it occurs at a smaller coating thickness (<100 nm vs >200 nm). Finally, using a separately determined coating refractive index (2.14, by ellipsometry on witness flats deposited simultaneously) and simulations of the resonance shifts of the TFBG with coating thickness, it is demonstrated that a TFBG connected to a spectral interrogation system can be used to measure the growth of a coating on the surface of the fiber in real time.Publication Open Access Resonances in coated long period fiber gratings and cladding removed multimode optical fibers: a comparative study(Optical Society of America, 2010) Del Villar, Ignacio; Ruiz Zamarreño, Carlos; Hernáez Sáenz de Zaitigui, Miguel; Arregui San Martín, Francisco Javier; Matías Maestro, Ignacio; Ingeniería Eléctrica y Electrónica; Ingeniaritza Elektrikoa eta ElektronikoaTwo optical fiber devices have been coated in parallel: a long period fiber grating (LPFG) and a cladding-removed multimode optical fiber (CRMOF). The progressive coating of the LPFG by means of the layer-by-layer electrostatic-self-assembly, permits to observe a resonance wavelength shift of the attenuation bands in the transmission spectrum. The cause of this wavelength shift is the reorganization of the cladding mode effective indices. The cause of this modal reorganization can be understood with the results observed in the CRMOF coated in parallel. A lossy-moderesonance (LMR) is generated in the same wavelength range of the LPFG attenuation bands analyzed. Moreover, the thickness range where the wavelength shift of the LPFG attenuation bands occurs coincides exactly with the thickness range where the LMR can be visualized in the transmission spectrum. These phenomena are analyzed theoretically and corroborated experimentally. The advantages and disadvantages of both optical fiber devices are explained.Publication Open Access Sensitivity enhancement experimental demonstration using a low cutoff wavelength SMS modified structure coated with a pH sensitive film(Elsevier, 2018) Rodríguez Rodríguez, Wenceslao Eduardo; Del Villar, Ignacio; Ruiz Zamarreño, Carlos; Matías Maestro, Ignacio; Arregui San Martín, Francisco Javier; Rodríguez Rodríguez, Adolfo Josué; Domínguez Cruz, René; Ingeniería Eléctrica y Electrónica; Ingeniaritza Elektrikoa eta Elektronikoa; Gobierno de Navarra / Nafarroako GobernuaThe multimode interference (MMI) effect in a single mode-multimode-single mode (SMS) can be used fordevelopment of wavelength shift detection based sensors. In this work, the focus is centered on obtainingwavelength shifts with low cutoff single mode fibers, which allows exploring the wavelength range from600 to 1000 nm, where optical sources and detectors are less expensive than at longer wavelengths. Inaddition, the application of a reduction in the fiber diameter of the SMS structure by means of HF etching,combined with the deposition of a thin-film, enables to enhance the sensitivity of the devices at thesame time the objective mentioned before is achieved. In this sense, the effect of the deposition of a pHsensitive thin-film on SMS structures with different diameters allowed attaining a maximum sensitivityof 15 nm per pH unit in the range from pH 4 to pH 6, which improves by a factor of 3 the sensitivity ofSMS sensors without etching operating at longer wavelengths.Publication Open Access D-shape optical fiber pH sensor based on lossy mode resonances (LMRs)(IEEE, 2016-01-07) Zubiate Orzanco, Pablo; Ruiz Zamarreño, Carlos; Del Villar, Ignacio; Matías Maestro, Ignacio; Arregui San Martín, Francisco Javier; Ingeniería Eléctrica, Electrónica y de Comunicación; Ingeniaritza Elektrikoa, Elektronikoa eta Telekomunikazio IngeniaritzaThe fabrication and characterization of an optical fiber pH sensor based on Lossy Mode Resonances (LMRs) is presented. PAH/PAA polymeric thin-films fabricated onto side-polished D-shaped optical fibers are used as LMR supporting coatings. The thickness of PAH/PAA coatings can be modified as a function of the external medium pH. As a consequence of this variation, the effective refractive index of the structure will change, producing a shift of the LMR. The fabricated sensor has been used to measure pH from 4.0 to 5.0. This pH sensor showed a sensitivity of 101.3 nm per pH unit, which means a resolution of ~6×10-4 pH units by using a conventional communications Optical Spectrum Analyzer (OSA), which is an improvement over commercial pH sensors.Publication Open Access Direct functionalization of TiO2/PSS sensing layer for an LMR-based optical fiber reusable biosensor(IEEE, 2023) Santano Rivero, Desiree; Socorro Leránoz, Abián Bentor; Del Villar, Ignacio; Ingeniería Eléctrica, Electrónica y de Comunicación; Institute of Smart Cities - ISC; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren; Universidad Pública de Navarra / Nafarroako Unibertsitate Publikoa, PJUPNA2033Functionalization plays a crucial role in the development of biosensors. In this study, bioreceptors were directly immobilized onto the surface of a sensing layer after physical activation, avoiding the need for longer and more complex functionalization systems. This direct immobilization was applied to an optical sensing platform based on lossy mode resonances (LMRs) generated by a thin-film of titanium (IV) dioxide/poly(sodium 4-styrenesulfonate) (TiO 2 /PSS). To generate the LMR, a 200-micron bare optical fiber was coated with TiO 2 /PSS using the layer-by-layer self-assembly technique. The PSS of the sensing layer was then physically activated using either UV-ozone or plasma to immobilize anti-rabbit IgG bioreceptors. This enabled specific and label-free detection of rabbit IgG concentrations ranging from 0.002 to 2 mg/ml. The results presented in this work include real-time detection of rabbit IgG, a comparison between the two activation techniques (UV-ozone and plasma), and an analysis of the biosensor’s reusability over four consecutive cycles, which demonstrates the promising potential of the TiO 2 /PSS sensing layer for biosensing applications.Publication Open Access Design rules for lossy mode resonance based sensors(Optical Society of America, 2012) Del Villar, Ignacio; Hernáez Sáenz de Zaitigui, Miguel; Ruiz Zamarreño, Carlos; Sánchez Zábal, Pedro; Fernández Valdivielso, Carlos; Arregui San Martín, Francisco Javier; Matías Maestro, Ignacio; Ingeniería Eléctrica y Electrónica; Ingeniaritza Elektrikoa eta Elektronikoa; Gobierno de Navarra / Nafarroako GobernuaLossy mode resonances can be obtained in the transmission spectrum of cladding removed multimode optical fiber coated with a thin-film. The sensitivity of these devices to changes in the properties of the coating or the surrounding medium can be optimized by means of the adequate parameterization of the coating refractive index, the coating thickness and the surrounding medium refractive index (SMRI). Some basic rules of design, which enable the selection of the best parameters for each specific sensing application, are indicated in this work.