Barrios Rípodas, Ernesto
Loading...
Email Address
person.page.identifierURI
Birth Date
Job Title
Last Name
Barrios Rípodas
First Name
Ernesto
person.page.departamento
Ingeniería Eléctrica, Electrónica y de Comunicación
person.page.instituteName
ISC. Institute of Smart Cities
ORCID
person.page.observainves
person.page.upna
Name
- Publications
- item.page.relationships.isAdvisorOfPublication
- item.page.relationships.isAdvisorTFEOfPublication
- item.page.relationships.isAuthorMDOfPublication
6 results
Search Results
Now showing 1 - 6 of 6
Publication Open Access Asymmetrical firing angle modulation for 12-pulse thyristor rectifiers supplying high-power electrolyzers(IEEE, 2023) Iribarren Zabalegui, Álvaro; Barrios Rípodas, Ernesto; Elizondo Martínez, David; Sanchis Gúrpide, Pablo; Ursúa Rubio, Alfredo; Ingeniería Eléctrica, Electrónica y de Comunicación; Institute of Smart Cities - ISC; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio IngeniaritzarenThis paper presents an asymmetrical firing angle modulation strategy for 12-pulse thyristor rectifiers aimed at supplying high-power electrolyzers, which allows to reduce the size of the passive filter and the static compensator (STATCOM) required to comply with grid harmonic regulations and achieve unity power factor. Usually, 12-pulse thyristor rectifiers follow a symmetric modulation strategy in which the same firing angle is applied to both 6-pulse bridges. In this case, large passive ac-side inductances are required to reduce grid current harmonics, which increase the reactive power consumption and thus the required STATCOM size. However, this paper demonstrates that by applying different firing angles to the two 6-pulse bridges it is possible to comply with the harmonic regulation limits using smaller filtering inductances and therefore reducing the STATCOM size. The methodology to find the optimal firing angle values that should be applied in order to minimize the filtering inductance and the STATCOM size for a given electrolyzer is explained. This strategy is validated by simulation, and results show that the required filtering inductance and the apparent power of the STATCOM can be effectively reduced by 62% and 31%, respectively, using this asymmetrical firing angle modulation.Publication Open Access Dynamic modeling and simulation of a pressurized alkaline water electrolyzer: a multiphysics approach(IEEE, 2021) Iribarren Zabalegui, Álvaro; Barrios Rípodas, Ernesto; Ibaiondo, Harkaitz; Sánchez Ruiz, Alain; Arza, Joseba; Sanchis Gúrpide, Pablo; Ursúa Rubio, Alfredo; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren; Institute of Smart Cities - ISC; Ingeniería Eléctrica, Electrónica y de ComunicaciónIn this paper a dynamic model for the simulation of pressurized alkaline water electrolyzers is presented. The model has been developed following a multiphysics approach, integrating electrochemical, thermodynamic, heat transfer and gas evolution processes in order to faithfully reproduce the complete dynamical behavior of these systems. The model has been implemented on MATLAB/Simulink and validated through experimental data from a 1 Nm3h-1 commercial alkaline water electrolyzer, and the simulated results have been found to be consistent with the real measured values. This model has a great potential to predict the behavior of alkaline water electrolyzers coupled with renewable energy sources, making it a very useful tool for designing efficient green hydrogen production systems.Publication Open Access Dynamic modeling of a pressurized alkaline water electrolyzer: a multiphysics approach(IEEE, 2023) Iribarren Zabalegui, Álvaro; Elizondo Martínez, David; Barrios Rípodas, Ernesto; Ibaiondo, Harkaitz; Sánchez Ruiz, Alain; Arza, Joseba; Sanchis Gúrpide, Pablo; Ursúa Rubio, Alfredo; Ingeniería Eléctrica, Electrónica y de Comunicación; Institute of Smart Cities - ISC; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio IngeniaritzarenIn this paper a dynamic model for the simulation of pressurized alkaline water electrolyzers is presented. The model has been developed following a multiphysics approach, integrating electrochemical, thermodynamic, heat transfer and gas evolution processes in order to faithfully reproduce the complete dynamical behavior of these systems. The model has been implemented on MATLAB/Simulink and validated through experimental data from a 1 Nm3/h commercial alkaline water electrolyzer. Validations have been performed under real scenarios where the electrolyzer is working with power profiles characteristic from renewable sources, wind and photovoltaic. The simulated results have been found to be consistent with the real measured values. This model has a great potential to predict the behavior of alkaline water electrolyzers coupled with renewable energy sources, making it a very useful tool for designing efficient green hydrogen production systems.Publication Open Access Modeling and optimal sizing of thyristor rectifiers for high-power hydrogen electrolyzers(IEEE, 2025-05-01) Iribarren Zabalegui, Álvaro; Barrios Rípodas, Ernesto; Sanchis Gúrpide, Pablo; Ursúa Rubio, Alfredo; Ingeniería Eléctrica, Electrónica y de Comunicación; Ingeniaritza Elektrikoa, Elektronikoa eta Telekomunikazio Ingeniaritza; Institute of Smart Cities - ISC; Universidad Pública de Navarra / Nafarroako Unibertsitate PublikoaThyristor rectifiers are currently the most common solution for supplying high-power electrolyzers. These rectifiers typically include a dc inductance, which significantly increases system costs. However, this inductance can be avoided by relying solely on ac-side inductances, required for grid current harmonic filtering, although this approach introduces specific challenges. Traditional analytical models of thyristor rectifiers are unable to determine the electrolyzer operating point for a given firing angle and may lead to incorrect system sizing, ultimately preventing the converter from delivering nominal power. This limitation arises from the fact that existing models are formulated for inductive or constant-current loads, whereas electrolyzers exhibit electrical behavior closer to constant-voltage loads. In this paper, a novel analytical model of 6- and 12-pulse thyristor rectifiers with constant-voltage load is developed. The model enables the analysis and optimal sizing of thyristor rectifiers directly connected to electrolyzers without a dc-side inductance. Its accuracy has been validated through both simulations and experimentally using a laboratory-scale prototype. Furthermore, the model has been applied to optimally size a 12-pulse rectifier supplying a 5.5 MW electrolyzer, demonstrating its suitability for the design of thyristor rectifier systems in industrial-scale electrolysis applications and highlighting its advantages over traditional approaches.Publication Open Access On the impact of high-power grid-connected thyristor rectifiers on the efficiency of hydrogen electrolyzers(IEEE, 2024-08-30) Iribarren Zabalegui, Álvaro; Barrios Rípodas, Ernesto; Rivera, Marco; Wheeler, Patrick; Sanchis Gúrpide, Pablo; Ursúa Rubio, Alfredo; Ingeniería Eléctrica, Electrónica y de Comunicación; Ingeniaritza Elektrikoa, Elektronikoa eta Telekomunikazio Ingeniaritza; Institute of Smart Cities - ISC; Universidad Pública de Navarra / Nafarroako Unibertsitate PublikoaThis paper investigates the impact of power supply and dc current ripple on the efficiency of water electrolyzers and demonstrates that optimally sized thyristor rectifiers meeting grid power quality regulations can effectively supply high-power electrolyzers with minimal impact on electrolyzer efficiency. Firstly, an equivalent electrical model for the electrolyzer is developed, and the efficiency reduction caused by dc current ripple is analyzed. This is validated by means of experimental data from a 5-kW alkaline electrolyzer operated with both thyristor- and IGBT-based rectifiers. Next, the paper explores the operation of high-power electrolyzers supplied by 6- and 12-pulse thyristor rectifiers complying with grid power quality standards. Results show that with optimal sizing of ac-side source voltage and filtering inductances, these solutions exhibit negligible dc current ripple impact on electrolyzer efficiency. These findings, validated through simulation of a 5.5 MW electrolyzer, highlight the viability of thyristor rectifiers in high-power electrolysis applications, and emphasize the importance of an optimal power supply design and sizing for enhancing water electrolyzers' performance.Publication Open Access Modelling and operation of 6-pulse thyristor rectifiers for supplying high power electrolyzers(IEEE, 2022) Iribarren Zabalegui, Álvaro; Barrios Rípodas, Ernesto; Ibaiondo, Harkaitz; Sánchez Ruiz, Alain; Arza, Joseba; Sanchis Gúrpide, Pablo; Ursúa Rubio, Alfredo; Ingeniería Eléctrica, Electrónica y de Comunicación; Institute of Smart Cities - ISC; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio IngeniaritzarenThis paper presents a detailed analysis of a 6-pulse thyristor rectifier aimed at supplying high power electrolyzers. For this purpose, an analytical model of the three-phase controlled rectifier with AC-side inductance and constant-voltage load has been developed. The different operating modes are identified and characterized. The derived equations are then combined with the electrical model of the electrolyzer, which allows to predict the operating point of the system. This model may serve as a useful tool for dimensioning thyristor rectifiers when operating with high power electrolyzers.