Arregui San Martín, Francisco Javier

Loading...
Profile Picture

Email Address

Birth Date

Job Title

Last Name

Arregui San Martín

First Name

Francisco Javier

person.page.departamento

Ingeniería Eléctrica, Electrónica y de Comunicación

person.page.instituteName

ISC. Institute of Smart Cities

person.page.observainves

person.page.upna

Name

Search Results

Now showing 1 - 10 of 106
  • PublicationOpen Access
    Resonances in coated long period fiber gratings and cladding removed multimode optical fibers: a comparative study
    (Optical Society of America, 2010) Del Villar, Ignacio; Ruiz Zamarreño, Carlos; Hernáez Sáenz de Zaitigui, Miguel; Arregui San Martín, Francisco Javier; Matías Maestro, Ignacio; Ingeniería Eléctrica y Electrónica; Ingeniaritza Elektrikoa eta Elektronikoa
    Two optical fiber devices have been coated in parallel: a long period fiber grating (LPFG) and a cladding-removed multimode optical fiber (CRMOF). The progressive coating of the LPFG by means of the layer-by-layer electrostatic-self-assembly, permits to observe a resonance wavelength shift of the attenuation bands in the transmission spectrum. The cause of this wavelength shift is the reorganization of the cladding mode effective indices. The cause of this modal reorganization can be understood with the results observed in the CRMOF coated in parallel. A lossy-moderesonance (LMR) is generated in the same wavelength range of the LPFG attenuation bands analyzed. Moreover, the thickness range where the wavelength shift of the LPFG attenuation bands occurs coincides exactly with the thickness range where the LMR can be visualized in the transmission spectrum. These phenomena are analyzed theoretically and corroborated experimentally. The advantages and disadvantages of both optical fiber devices are explained.
  • PublicationOpen Access
    High sensitivity optical fiber pH sensor using poly(acrylic acid) nanofibers
    (IEEE, 2013-12-19) Corres Sanz, Jesús María; Arregui San Martín, Francisco Javier; Matías Maestro, Ignacio; Rodríguez García, Yoany; Ingeniería Eléctrica y Electrónica; Ingeniaritza Elektrikoa eta Elektronikoa
    In this work a new optical fiber pH sensor based on the deposition of poly(acrylic acid) (PAA) using the electrospinning technique is presented. The optical fiber structure consists of a 4 cm segment of hollow core fiber (50/150¿m) spliced between two standard multimode fibers onto which the nanoweb is deposited. The sensitive layer is a membrane composed by PAA nanofibers deposited onto the surface of an optical fiber. The sensor has a repetitive behavior and low hysteresis in the pH range 4-7, with an average sensitivity of 0,53 dB/pH.
  • PublicationOpen Access
    Fiber-based label-free D-dimer detection for early diagnosis of venous thromboembolism
    (SPIE, 2020) Zubiate Orzanco, Pablo; Urrutia Azcona, Aitor; Ruiz Zamarreño, Carlos; Fernández Irigoyen, Joaquín; Giannetti, Ambra; Baldini, Francesco; Díaz Lucas, Silvia; Matías Maestro, Ignacio; Arregui San Martín, Francisco Javier; Santamaría Martínez, Enrique; Del Villar, Ignacio; Chiavaioli, Francesco; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren; Institute of Smart Cities - ISC; Ingeniería Eléctrica, Electrónica y de Comunicación
    D-dimer is a useful diagnostic biomarker for deep vein thrombosis or pulmonary embolism, collectively referred to as venous thromboembolism (VTE). The ability to detect in real-time the amount of D-dimer with a fast and reliable method is a key step to anticipate the appearance of these diseases. The combination of fiber-optic-based platforms for biosensing with the nanotechnologies is opening up the chance for the development of in situ, portable, lightweight, versatile, reliable and high-performance optical sensing devices towards lab-on-fiber technology. The generation of lossy mode resonances (LMRs) by means of the deposition of nm-thick absorbing metal-oxide films on special geometric-modified fibers allows measuring precisely and accurately surface refractive index changes, which are due to the binding interaction between a biological recognition element and the analyte under investigation. This approach enhances the light-matter interaction in a strong way, thus turning out to be more sensitive compared to other optical technology platforms, such as fiber gratings or surface plasmon resonance. Here, the results of a highly specific and sensitive biosensor for the detection of D-dimer based on LMR in fiber-optics are presented by monitoring in real-time the shift of the LMR related to the biomolecule interactions thanks to a conventional wavelength-interrogation system and an ad-hoc developed microfluidics. A detection limit of 100 ng/mL, a value 5-fold below the clinical cutoff value, has been attained for D-dimer spiked in human serum. The comparison of the results achieved with proteomics-based methodologies, which allows for the identification of betaand gamma-chains of fibrinogen, demonstrates the ability of our platform to specifically (>90%) recognize D-dimer.
  • PublicationOpen Access
    Experimental demonstration of lossy mode resonance generation for transverse-magnetic and transverse-electric polarizations
    (Optica Publishing Group, 2013) Ruiz Zamarreño, Carlos; Zubiate Orzanco, Pablo; Sagüés García, Mikel; Matías Maestro, Ignacio; Arregui San Martín, Francisco Javier; Ingeniería Eléctrica y Electrónica; Ingeniaritza Elektrikoa eta Elektronikoa
    This Letter, presents the fabrication of lossy mode resonance (LMR) devices based on titanium dioxide (TiO2)/ poly(sodium 4-styrenesulfonate) (PSS) coatings deposited on side-polished D-shaped optical fibers. TiO2 thin films have been obtained by means of the layer-by-layer (LbL) self-assembly technique. LbL enables us to produce smooth and homogeneous coatings on the polished side of the fiber. This permits us to couple light from the waveguide to the TiO2-coating/external medium region at specific wavelength ranges. The generation of LMRs depends on the coating thickness, so that thicker coatings can produce more resonances. LMRs are sensitive to the external medium refractive index, which allows its utilization as refractometers. The characteristic D-shaped architecture of the devices employed in this Letter enables us to distinguish TE and TM polarizations, which had not been possible before with regular optical fibers due to their cylindrical symmetry. The results presented here show for the first time the experimental demonstration of the generation of LMRs produced by both TM and TE polarizations. More specifically, for these TiO2/PSS thin films, the TM and TM modes of the LMRs show a wavelength shift of 226 nm for the first-order LMR and 56 nm for the second-order LMR.
  • PublicationOpen Access
    An antibacterial submicron fiber mat with in situ synthesized silver nanoparticles
    (Wiley, 2012) Rivero Fuente, Pedro J.; Urrutia Azcona, Aitor; Goicoechea Fernández, Javier; Rodríguez, Yoany; Corres Sanz, Jesús María; Arregui San Martín, Francisco Javier; Matías Maestro, Ignacio; Ingeniería Eléctrica, Electrónica y de Comunicación; Ingeniaritza Elektrikoa, Elektronikoa eta Telekomunikazio Ingeniaritza; Institute of Smart Cities - ISC; Ingeniería; Ingeniaritza; Institute for Advanced Materials and Mathematics - INAMAT2
    This work presents an alternative approachfor fabricating electrospun submicron highly hydrophilicfiber mats loaded with silver nanoparticles. These fiber matsshow a high efficient antibacterial behavior, very attractivefor applications like wound healing and skin regenerationprocesses. The fabrication method is divided in two steps.First, poly(acrylic acid) (PAA) and b-cyclodextrin (b-CD)submicron fibers were electrospun and further stabilizedusing a thermal treatment, yielding stable hydrogel-likefibers with diameters ranging from 100 nm up to severalmicrons. In the second step, silver ions were loaded into thefibers and then reduced to silver nanoparticles in-situ. Theelectrospinning parameters were adjusted to achieve thedesired properties of the fiber mat (density, size) and after-wards, the characteristics of the silver nanoparticles(amount, size, aggregation) were tuned by controlling thesilver ion loading mechanism. Highly biocide surfaces wereachieved showing more than 99.99% of killing efficiency.The two-step process improves the reproducibility and tun-ability of the fiber mats. To our knowledge, this is the firsttime that stable hydrogel fibers with a highly biocide behav-ior have been fabricated using electrospinning.
  • PublicationOpen Access
    Sensitivity enhancement experimental demonstration using a low cutoff wavelength SMS modified structure coated with a pH sensitive film
    (Elsevier, 2018) Rodríguez Rodríguez, Wenceslao Eduardo; Del Villar, Ignacio; Ruiz Zamarreño, Carlos; Matías Maestro, Ignacio; Arregui San Martín, Francisco Javier; Rodríguez Rodríguez, Adolfo Josué; Domínguez Cruz, René; Ingeniería Eléctrica y Electrónica; Ingeniaritza Elektrikoa eta Elektronikoa; Gobierno de Navarra / Nafarroako Gobernua
    The multimode interference (MMI) effect in a single mode-multimode-single mode (SMS) can be used fordevelopment of wavelength shift detection based sensors. In this work, the focus is centered on obtainingwavelength shifts with low cutoff single mode fibers, which allows exploring the wavelength range from600 to 1000 nm, where optical sources and detectors are less expensive than at longer wavelengths. Inaddition, the application of a reduction in the fiber diameter of the SMS structure by means of HF etching,combined with the deposition of a thin-film, enables to enhance the sensitivity of the devices at thesame time the objective mentioned before is achieved. In this sense, the effect of the deposition of a pHsensitive thin-film on SMS structures with different diameters allowed attaining a maximum sensitivityof 15 nm per pH unit in the range from pH 4 to pH 6, which improves by a factor of 3 the sensitivity ofSMS sensors without etching operating at longer wavelengths.
  • PublicationOpen Access
    D-shape optical fiber pH sensor based on lossy mode resonances (LMRs)
    (IEEE, 2016-01-07) Zubiate Orzanco, Pablo; Ruiz Zamarreño, Carlos; Del Villar, Ignacio; Matías Maestro, Ignacio; Arregui San Martín, Francisco Javier; Ingeniería Eléctrica, Electrónica y de Comunicación; Ingeniaritza Elektrikoa, Elektronikoa eta Telekomunikazio Ingeniaritza
    The fabrication and characterization of an optical fiber pH sensor based on Lossy Mode Resonances (LMRs) is presented. PAH/PAA polymeric thin-films fabricated onto side-polished D-shaped optical fibers are used as LMR supporting coatings. The thickness of PAH/PAA coatings can be modified as a function of the external medium pH. As a consequence of this variation, the effective refractive index of the structure will change, producing a shift of the LMR. The fabricated sensor has been used to measure pH from 4.0 to 5.0. This pH sensor showed a sensitivity of 101.3 nm per pH unit, which means a resolution of ~6×10-4 pH units by using a conventional communications Optical Spectrum Analyzer (OSA), which is an improvement over commercial pH sensors.
  • PublicationOpen Access
    Sensors based on thin-film coated cladding removed multimode optical fiber and single-mode multimode single-mode fiber: a comparative study
    (Hindawi Publishing Corporation, 2015) Del Villar, Ignacio; Socorro Leránoz, Abián Bentor; Hernáez Sáenz de Zaitigui, Miguel; Corres Sanz, Jesús María; Ruiz Zamarreño, Carlos; Sánchez Zábal, Pedro; Arregui San Martín, Francisco Javier; Matías Maestro, Ignacio; Ingeniería Eléctrica y Electrónica; Ingeniaritza Elektrikoa eta Elektronikoa
    Two simple optical fibre structures that do not require the inscription of a grating, a cladding removed multimode optical fibre (CRMOF) and a single-mode multimode single-mode structure (SMS), are compared in terms of their adequateness for sensing once they are coated with thin-films.The thin-film deposited (TiO2/PSS) permits increasing the sensitivity to surrounding medium refractive index. The results obtained can be extrapolated to other fields such as biological or chemical sensing just by replacing the thin-film by a specific material.
  • PublicationOpen Access
    SnO2 based optical fiber refractometers
    (SPIE, 2012) Sánchez Zábal, Pedro; Ruiz Zamarreño, Carlos; Hernáez Sáenz de Zaitigui, Miguel; Del Villar, Ignacio; Matías Maestro, Ignacio; Arregui San Martín, Francisco Javier; Ingeniería Eléctrica y Electrónica; Ingeniaritza Elektrikoa eta Elektronikoa; Gobierno de Navarra / Nafarroako Gobernua
    In this work, the fabrication and characterization of refractometers based on lossy mode resonances (LMR) is presented. Tin dioxide (SnO2) films deposited on optical fibers are used as the LMR supporting coatings. These resonances shift to the red as a function of the external refractive index, enabling the fabrication of robust and highly reproducible wavelength-based optical fiber refractometers. The obtained SnO2-based refractometer shows an average sensitivity of 7198 nm/refractive index unit (RIU) in the range 1.333-1.420 RIU.
  • PublicationOpen Access
    Strategies for fabrication of hydrogen peroxide sensors based on electrostatic self-assembly (ESA) method
    (Elsevier, 2004) Del Villar, Ignacio; Matías Maestro, Ignacio; Arregui San Martín, Francisco Javier; Echeverría Morrás, Jesús; Claus, Richard O.; Ingeniería Eléctrica y Electrónica; Ingeniaritza Elektrikoa eta Elektronikoa; Gobierno de Navarra / Nafarroako Gobernua
    An optical fiber sensor has been fabricated for detection of 5 M–0.1mM concentrations of hydrogen peroxide with a linear response. The deposition method used is electrostatic self-assembly (ESA) of polymer cationic and anionic layers. Prussian Blue (PB) has been included in the polycation layers. The optical fiber sensor is included in a reflection setup, where the measuring technique is based on the slope of the optical reflected power change caused by oxidation of Prussian White (PW) to Prussian Blue. The sensor recovers after immersion in a reductive agent and is immune against a variety of components. Measurement of hydrogen peroxide has been proved successfully in a wide range pHs between 3 and 9. Some techniques have been applied in order to avoid the lost of indicator.