Samanes Pascual, Javier

Loading...
Profile Picture

Email Address

Birth Date

Job Title

Last Name

Samanes Pascual

First Name

Javier

person.page.departamento

Ingeniería Eléctrica, Electrónica y de Comunicación

person.page.instituteName

ISC. Institute of Smart Cities

person.page.observainves

person.page.upna

Name

Search Results

Now showing 1 - 10 of 22
  • PublicationOpen Access
    Active damping based on the capacitor voltage positive-feedback for grid-connected power converters with LCL filter
    (IEEE, 2019) Samanes Pascual, Javier; Gubía Villabona, Eugenio; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren; Institute of Smart Cities - ISC; Ingeniería Eléctrica, Electrónica y de Comunicación
    The capacitor voltage positive-feedback is a widely extended active damping strategy. It can effectively damp the LCL output filter resonant poles for low ratios of resonance to sampling frequencies. However, the existing delays in the control loop limit the applicability of the capacitor-voltage positive-feedback. For high ratios of resonance to sampling frequencies, it becomes ineffective and can even destabilize the system. This limitation is overcome in this paper by adjusting the delay in the feedback path. With the delay adjustment, a robust damping can be achieved if the delays are properly considered, including the filters, and the grid impedance variations are taken into account. Simulation results validate the proposed active damping strategy.
  • PublicationOpen Access
    Control strategy for a droop-controlled grid-connected DFIG wind turbine
    (IEEE, 2022) Oraa Iribarren, Iker; Samanes Pascual, Javier; López Taberna, Jesús; Gubía Villabona, Eugenio; Ingeniería Eléctrica, Electrónica y de Comunicación; Institute of Smart Cities - ISC; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren
    The application of droop control techniques without inner current control loops to doubly-fed induction generator (DFIG) based wind turbines does not allow to provide a stable response at all operating points in terms of rotational speed and active and reactive power. After modeling the system dynamics and analyzing the causes of instability, this paper proposes a control strategy that allows to stabilize the system response at all possible operating points. Simulation results performed in MATLAB/Simulink validate the proposed control strategy proving its effectiveness.
  • PublicationOpen Access
    On the limits of the capacitor-voltage active damping for grid-connected power converters with LCL filter
    (IEEE, 2018) Samanes Pascual, Javier; Gubía Villabona, Eugenio; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren; Institute of Smart Cities - ISC; Ingeniería Eléctrica, Electrónica y de Comunicación; Universidad Pública de Navarra / Nafarroako Unibertsitate Publikoa
    Active damping strategies are widely extended to avoid stability issues at the LCL filter resonant poles in grid-connected voltage source converters. The capacitor voltage derivative active damping effectively damps the filter resonant poles without additional sensors, but it loses its effectiveness as the resonance frequency approaches the converter control Nyquist frequency, influenced by the existing delays in the control loop. To reduce this limitation, the delays can be reduced by performing a multisampled derivative, however, even though the stability limits might be extended, the oversampled approach might increase noise amplification problems. An appropriate filtering solution is required in the feedback path in order to reduce noise amplification and eliminate aliasing problems, without compromising the stability, as a result of a modification in the active damping feedback path. This work examines the limits of applicability of the capacitor voltage derivative strategy taking into account the filters used in the AD path, providing experimental results to validate the presented approach.
  • PublicationOpen Access
    Control design and stability analysis of power converters: the discrete generalized Bode criterion
    (IEEE, 2021) Urtasun Erburu, Andoni; Samanes Pascual, Javier; Barrios Rípodas, Ernesto; Sanchis Gúrpide, Pablo; Ingeniería Eléctrica, Electrónica y de Comunicación; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren
    For the controller design and stability analysis of power electronic converters, the Bode stability criterion and its subsequent revisions are the most practical tools. However, even though the control of the power converter is usually implemented in a microprocessor, none of these methods is infallible when applied to a discrete system. This article therefore proposes a new stability criterion, named the Discrete Generalized Bode Criterion (DGBC). This method is based on the Nyquist criterion but developed from the open-loop Bode diagram, evaluated also at 0 Hz and at the Nyquist frequency. The proposed criterion combines the advantages of the Nyquist and Bode criteria, since it is always applicable and provides an interesting and useful tool for the controller design process. The method is applied to design an active damping control of an inverter with LCL filter, showing how the proposed criterion accurately predicts stability, in contrast to the existing Bode criteria. The theoretical analysis is validated through experimental results performed with a three-phase inverter and an LCL filter.
  • PublicationOpen Access
    Robust active damping strategy for DFIG wind turbines
    (IEEE, 2021) Rosado Galparsoro, Leyre; Samanes Pascual, Javier; Gubía Villabona, Eugenio; López Taberna, Jesús; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren; Institute of Smart Cities - ISC; Ingeniería Eléctrica, Electrónica y de Comunicación
    Doubly fed induction generators (DFIGs) with an LCL filter are widely used for wind power generation. In these energy conversion systems, there is an interaction between the grid-side converter (GSC) and the rotor-side converter (RSC) control loops, the generator and the LCL filter that must be properly modeled. Such interaction between the GSC and the RSC proves to have a significant influence on the stability. Several active damping (AD) methods for grid-connected converters with an LCL filter have been proposed, nevertheless, the application of these techniques to a DFIG wind turbine is not straightforward, as revealed in this article. To achieve a robust damping irrespective of the grid inductance, this article proposes an AD strategy based on the capacitor current feedback and the adjustment of the control delays to emulate a virtual impedance, in parallel with the filter capacitor, with a dominant resistive component in the range of possible resonance frequencies. This work also proves that, by applying the AD strategy in both converters simultaneously, the damping of the system resonant poles is maximized when a specific value of the grid inductance is considered. Experimental results show the interaction between the GSC and the RSC and validate the proposed AD strategy. © 1986-2012 IEEE.
  • PublicationOpen Access
    Multisampled-capacitor-voltage active damping for parallel interleaved grid connected voltage source converters with LCL filter
    (IEEE, 2017) Samanes Pascual, Javier; Gubía Villabona, Eugenio; Institute of Smart Cities - ISC; Universidad Pública de Navarra / Nafarroako Unibertsitate Publikoa
    Parallel interleaved converters for high power renewable energy systems present stability issues at the LCL resonance frequency. A multisampled measurement and filtering strategy is proposed to stabilize the system based on the capacitor voltage derivative active damping, overcoming its limitations for low switching power converters. The effects of the delays on the stability of the active damping strategy would be analysed. The solution developed is robust against grid inductance variations, ensuring the fulfilment of the stringent harmonic grid codes.
  • PublicationOpen Access
    MIMO based decoupling strategy for grid connected power converters controlled in the synchronous reference frame
    (IEEE, 2018) Samanes Pascual, Javier; Gubía Villabona, Eugenio; López Taberna, Jesús; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren; Institute of Smart Cities - ISC; Ingeniería Eléctrica, Electrónica y de Comunicación; Universidad Pública de Navarra / Nafarroako Unibertsitate Publikoa
    Power converters are frequently connected to the grid through a LCL filter, controlling its power transfer through a current control loop in the synchronous reference frame. In this reference frame, cross coupling terms appear between the current and voltages of the passive components, which, without a proper decoupling strategy, penalize the converter transient response and the current control adjustment. In this work, an intuitive decoupling strategy is presented to improve the dynamic behavior, based on Multiple-Input-Multiple-Output systems theory. The approach developed is particularly interesting in extremely weak grids, allowing an easier adjustment of the main controller.
  • PublicationOpen Access
    Hydrogen educational activities developed by APERNA: a renewable-energy student association
    (Asociación Española del Hidrógeno, 2016) Berrueta Irigoyen, Alberto; San Martín Biurrun, Idoia; Samanes Pascual, Javier; Pascual Miqueleiz, Julio María; Barrios Rípodas, Ernesto; Parra Laita, Íñigo de la; Urtasun Erburu, Andoni; Sanchis Gúrpide, Pablo; Ursúa Rubio, Alfredo; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren; Institute of Smart Cities - ISC; Ingeniería Eléctrica, Electrónica y de Comunicación
    In this paper, we present APERNA, a recently-created student association at Public University of Navarre (UPNA) with the aim of promotion of renewable energies.
  • PublicationOpen Access
    Robust multisampled capacitor voltage active damping for grid-connected power converters
    (Elsevier, 2019) Samanes Pascual, Javier; Urtasun Erburu, Andoni; Gubía Villabona, Eugenio; Petri, Alberto; Ingeniería Eléctrica, Electrónica y de Comunicación; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren; Universidad Pública de Navarra / Nafarroako Unibertsitate Publikoa
    The derivative feedback of the capacitor voltage is one of the most extended active damping strategies, used to eliminate stability problems in grid-connected power converters with an LCL filter. This strategy is equivalent to the implementation of a virtual impedance in parallel with the filter capacitor. This virtual impedance is strongly affected by the control loop delays and frequency, creating changes in the sign of the emulated virtual resistor, and raising instability regions where the active damping is ineffective. As a consequence, the LCL resonance frequency is restricted to vary, as the effective grid inductance changes, within the active damping stability region. This is an additional restriction imposed on the LCL filter design that can compromise the achievement of an optimised design. For this reason, in this work, a different strategy is presented; by adjusting the delay in the active damping feedback path, it becomes stable within the range where the LCL resonance frequency can be located for a given filter design, achieving a robust damping. Analytical expressions are provided to adjust this delay. To widen the stability region of the capacitor voltage derivative active damping, a multisampled derivative is implemented, overcoming its limitations close to the control Nyquist frequency. Experimental and simulation results validate the active damping strategy presented.
  • PublicationOpen Access
    Strategies for improving the efficiency and grid-connection stability of power converters for wind energy systems
    (2018) Samanes Pascual, Javier; Gubía Villabona, Eugenio; Ingeniería Eléctrica, Electrónica y de Comunicación; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren; Universidad Pública de Navarra / Nafarroako Unibertsitate Publikoa
    La energía eólica es una de las principales fuentes de generación renovable, una tecnología que continúa expandiéndose gracias a la reducción de costes y a la mayor concienciación ambiental de la sociedad. Esta expansión a nivel mundial está provocando que las turbinas eólicas se conecten a redes débiles, que plantean nuevos problemas de estabilidad. Asimismo, para continuar avanzando en la reducción del coste de la energía generada, la eficiencia de los sistemas de generación eólica, y consecuentemente del convertidor de potencia, se convierte en un aspecto clave. Por ultimo, existe una tendencia entre los principales fabricantes de aerogeneradores a incrementar el tamaño de las turbinas, aprovechando las economías de escala existentes. Esta tendencia está forzando a buscar nuevas estructuras de conversión para estas turbinas que alcanzan hoy en día los 9 MW. Dentro de este contexto general, en esta tesis se abordan las siguientes líneas de investigación: - Modelo detallado de los lazos de control de un convertidor de conexión a red. - Mejora de la respuesta din amica del convertidor. - Mejora de la estabilidad y de la eficiencia de convertidores de conexión a red al amortiguar el filtro de salida mediante el control. - Incremento de la eficiencia gracias a la utilización de modulaciones específicas para convertidores eólicos. - Análisis de las estructuras de conversión para turbinas eólicas de gran potencia y extensión a estos sistemas de las técnicas anteriores.