Now showing 1 - 9 of 9
  • PublicationOpen Access
    SnO2-MOF-Fabry-Perot optical sensor for relative humidity measurements
    (Elsevier, 2018) López Aldaba, Aitor; López Torres, Diego; Elosúa Aguado, César; Auguste, Jean-Louis; Jamier, Raphael; Roy, Philippe; Arregui San Martín, Francisco Javier; López-Amo Sáinz, Manuel; Ingeniaritza Elektrikoa eta Elektronikoa; Institute of Smart Cities - ISC; Ingeniería Eléctrica y Electrónica
    In this paper, a new optical fiber sensor for relative humidity measurements is presented and characterized. The sensor is based on a SnO2 sputtering deposition on a microstructured optical fiber (MOF) low-finesse Fabry-Pérot (FP) sensing head. The feasibility of the device as a breathing sensor is also experimentally demonstrated. The interrogation of the sensing head is carried out by monitoring the Fast Fourier Transform phase variations of the FP interference frequency. This method substitutes the necessity of tracking the optical spectrum peaks or valleys, which can be a handicap when noise or multiple contributions are present: therefore, it is low-sensitive to noise and to artifacts signal amplitude. The sensor shows a linear behavior in a wide relative humidity range (20%–90% relative humidity) in which the sensitivity is 0.14 rad/%; the maximum observed instability is 0.007 rad, whereas the highest hysteresis is 5% RH. The cross correlation with temperature is also considered and a method to lower its influence is proposed. For human breathing measurement, the registered rising and recovery times are 370 ms and 380 ms respectively.
  • PublicationOpen Access
    Real time measuring system of multiple chemical parameters using microstructured optical fibers based sensors
    (IEEE, 2018) López Aldaba, Aitor; López Torres, Diego; Elosúa Aguado, César; Arregui San Martín, Francisco Javier; Auguste, Jean-Louis; Jamier, Raphael; Roy, Philippe; López-Amo Sáinz, Manuel; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren; Institute of Smart Cities - ISC; Ingeniería Eléctrica, Electrónica y de Comunicación
    In this paper, a multiplexing system for simultaneous interrogation of optical fiber sensors which measure different parameters is presented and validated. The whole system has been tested with 6 different sensing heads with different purposes: one temperature sensing head, two relative humidity sensors and three VOCs leak sensors; all of them based on microstructured optical fibers. The interrogation system uses the FFT technique to isolate each sensor's interference, enabling their simultaneous interrogation. The system interrogates all the sensors at frequencies up to 1 KHz, showing a good performance of each measurement without crosstalk between sensors. The developed system is independent of the sensors' purpose or of the multiplexing topology.
  • PublicationOpen Access
    Enhancement of the sensitivity of a volatile organic compounds MOF sensor by means of its structure
    (MDPI, 2019) López Torres, Diego; López Aldaba, Aitor; Elosúa Aguado, César; Auguste, Jean-Louis; Jamier, Raphael; Roy, Philippe; López-Amo Sáinz, Manuel; Arregui San Martín, Francisco Javier; Ingeniería Eléctrica y Electrónica; Ingeniaritza Elektrikoa eta Elektronikoa; Institute of Smart Cities - ISC; Universidad Pública de Navarra / Nafarroako Unibertsitate Publikoa
    In this paper, we experimentally compare several core structures of Microstructured Optical Fibers (MOFs) for low-finesse Fabry-Pérot (FP) sensors. These sensors are designed for Volatile Organic Compounds (VOCs) measurements. We deposit Indium Tin Oxide (ITO) thin films by sputtering on the MOFs and different optical phase responses of the FP were measured for saturated atmospheres of ethanol. The sensitivity of the developed sensors is demonstrated to depend on the geometry and the dimensions of the MOF-cores. The sensors show recovery times under 100 s and the baselines are fully recovered after exposure to VOC.
  • PublicationOpen Access
    Microstructured optical fiber sensor for soil moisture measurements
    (Optical Society of America, 2018) López Aldaba, Aitor; López Torres, Diego; Campo-Bescós, Miguel; López Rodríguez, José Javier; Yerro Lizarazu, David; Elosúa Aguado, César; Arregui San Martín, Francisco Javier; Auguste, Jean-Louis; Jamier, Raphael; Roy, Philippe; López-Amo Sáinz, Manuel; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren; Ingeniaritza; Institute of Smart Cities - ISC; Ingeniería Eléctrica, Electrónica y de Comunicación; Ingeniería
    A discrete sensor based on a Sn0₂-FP (Fabry-Pérot) cavity is presented and characterized in real soil conditions. Results are compared, for the first time to our knowledge, with a commercial capacitive sensor and gravimetric measurements.
  • PublicationOpen Access
    Comparison between capacitive and microstructured optical fiber soil moisture sensors
    (MDPI, 2018) López Aldaba, Aitor; López Torres, Diego; Campo-Bescós, Miguel; López Rodríguez, José Javier; Yerro Lizarazu, David; Elosúa Aguado, César; Arregui San Martín, Francisco Javier; Auguste, Jean-Louis; Jamier, Raphael; Roy, Philippe; López-Amo Sáinz, Manuel; Ingeniaritza Elektrikoa eta Elektronikoa; Landa Ingeniaritza eta Proiektuak; Institute of Smart Cities - ISC; Institute on Innovation and Sustainable Development in Food Chain - ISFOOD; Ingeniería Eléctrica y Electrónica; Proyectos e Ingeniería Rural
    Soil moisture content has always been an important parameter to control because it is a deterministic factor for site-specific irrigation, seeding, transplanting, and compaction detection. In this work, a discrete sensor that is based on a SnO2–FP (Fabry-Pérot) cavity is presented and characterized in real soil conditions. As far as authors know, it is the first time that a microstructured optical fiber is used for real soil moisture measurements. Its performance is compared with a commercial capacitive soil moisture sensor in two different soil scenarios for two weeks. The optical sensor shows a great agreement with capacitive sensor’s response and gravimetric measurements, as well as a fast and reversible response; moreover, the interrogation technique allows for several sensors to be potentially multiplexed, which offers the possibility of local measurements instead of volumetric: it constitutes a great tool for real soil moisture monitoring.
  • PublicationOpen Access
    Development of new punctual optical fiber transducer for sensing
    (2018) López Aldaba, Aitor; López-Amo Sáinz, Manuel; Bariáin Aisa, Cándido; Ingeniería Eléctrica, Electrónica y de Comunicación; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren
    The international research community has been nurturing photonic technologies over the years, aiming to develop cost effective solutions for a number of applications. Optical fibers offer an efficient solution for sensing and communication fields. Fiber optic sensors present appealing characteristics that make them very attractive when compared with conventional electric sensors such as immunity to electromagnetic interferences, as well as unfavorable environments, small size, ability for multiplexing and remote sensing. Another important aspect when using optical fibers is the ability to simultaneously use them as sensors and communication channels. The primary motivation for this PhD work was the study and development of new structures based in photonic crystal fibers. The main idea was to take advantage of the know-how of our group in fiber-optic communications and photonic sensing, as well as the recent advances in the sensing area to develop new structures based on the platform of photonic crystal fibers.
  • PublicationOpen Access
    Sensitivity optimization of a microstructured optical fiber ammonia gas sensor by means of tuning the thickness of a metal oxide nano-coating
    (IEEE, 2019) López Torres, Diego; López Aldaba, Aitor; Elosúa Aguado, César; Auguste, Jean-Louis; Jamier, Raphael; Roy, Philippe; López-Amo Sáinz, Manuel; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren; Institute of Smart Cities - ISC; Ingeniería Eléctrica, Electrónica y de Comunicación; Universidad Pública de Navarra / Nafarroako Unibertsitate Publikoa
    In this paper, the influence of the thickness of metallic-oxide coatings, ITO, and SnO2 on the sensitivity of a microstructured optical fiber Fabry–Pérot (FP) has been studied with the aim of developing ammonia gas fiber optic sensors. Also, the distribution of the optical power that can be coupled to the metallic-oxide sensing films is investigated in order to understand how the sensor’s sensitivity can be improved; the thickness of the coatings plays a relevant role on the sensitivity and response time. Films with thicknesses between 200 and 850 nm were experimentally examined resulting in an optimal thickness of 625 nm for a SnO2 film. The behavior of the sensors toward different concentrations of ammonia gas from 10 to 130 ppm was analyzed by measuring the phase shifts of the reflected signal using the fast Fourier transform of its optical spectrum. The registered response/recovery times of this sensor are below 90 s.
  • PublicationOpen Access
    Simultaneous strain and temperature multipoint sensor based on microstructured optical fiber
    (IEEE, 2018) López Aldaba, Aitor; Auguste, Jean-Louis; Jamier, Raphael; Roy, Philippe; López-Amo Sáinz, Manuel; Ingeniaritza Elektrikoa eta Elektronikoa; Institute of Smart Cities - ISC; Ingeniería Eléctrica y Electrónica
    In this paper, a new sensor system for simultaneous and independent multipoint strain and temperature measurements is presented. The interrogation of the sensing heads has been carried out by monitoring their FFT phase variations. In particular, two of each microstructured optical fiber (M0F) cavity interference frequencies were used for the measures. This method is independent of the signal amplitude and also avoids the necessity of tracking the wavelength evolution in the spectrum, which can be a handicap when there are multiple interference frequency components with different sensitivities. The sensing heads present birefringent and multimodal properties and therefore both characteristics lead to their own interference with different properties and sensitivities. The multiplexing capability of the sensing heads and the interrogator method has also been tested and validated. Sensors were operated within a range of temperature 30°C-80°C and a deformation of ̴450 με was applied. Crosstalk between measurements can be corrected through simple math operations leading to independent and crosstalk-free multipoint and multiparameter sensors.
  • PublicationOpen Access
    Comparison between different structures of suspended-core microstructured optical fibers for volatiles sensing
    (MDPI, 2018) López Torres, Diego; López Aldaba, Aitor; Elosúa Aguado, César; Auguste, Jean-Louis; Jamier, Raphael; Roy, Philippe; López-Amo Sáinz, Manuel; Arregui San Martín, Francisco Javier; Ingeniaritza Elektrikoa, Elektronikoaren eta Telekomunikazio Ingeniaritzaren; Institute of Smart Cities - ISC; Ingeniería Eléctrica, Electrónica y de Comunicación; Universidad Pública de Navarra / Nafarroako Unibertsitate Publikoa
    In this paper, different core structures of microstructured optical fibers (MOFs) for low-finesse Fabry-Perot (FP) sensors are experimentally compared to get the highest sensitivity. These devices are designed for volatile organic compounds (VOCs) measurements. Indium tin oxide (ITO) thin films were deposited by sputtering on the MOFs and different optical fast Fourier transform (FFT) phase responses from the FP were measured for saturated atmospheres of ethanol. It has been demonstrated that the sensitivities of the developed sensors depend strongly on the geometry and the dimensions of the MOF-cores. The sensors show recovery times shorter than 100 s and the baselines are fully recovered after every exposure to ethanol vapors.