Validez diagnóstica de la ecografía en el síndrome del túnel carpiano

dc.contributor.authorBueno-Gracia, Elena
dc.contributor.authorHaddad-Garay, María
dc.contributor.authorTricás-Moreno, José Miguel
dc.contributor.authorFanlo-Mazas, Pablo
dc.contributor.authorMalo-Urriés, Miguel
dc.contributor.authorEstébanez-de-Miguel, Elena
dc.contributor.authorHidalgo-García, César
dc.contributor.authorRuiz de Escudero Zapico, Alazne
dc.contributor.departmentCiencias de la Saludes_ES
dc.contributor.departmentOsasun Zientziakeu
dc.date.accessioned2025-01-30T16:12:33Z
dc.date.available2025-01-30T16:12:33Z
dc.date.issued2015
dc.date.updated2025-01-30T15:54:17Z
dc.description.abstractIntroducción. La ecografía ha emergido como una herramienta diagnóstica alternativa de las neuropatías periféricas, como el síndrome del túnel carpiano (STC). Sin embargo, faltan datos sobre la validez diagnóstica de las diferentes mediciones ecográficas para la detección del STC en entornos clínicos. Objetivo. Hallar la validez diagnóstica de las mediciones ecográficas del área de sección transversal del nervio mediano en la muñeca (AST-M) y de la ratio del área del nervio mediano entre la muñeca y el antebrazo (R-MA) en el diagnóstico del STC, utilizando como técnica de referencia el electroneurograma (ENG). Pacientes y métodos. Se realizaron mediciones ecográficas en 59 sujetos (97 muñecas) referidos para someterse a un ENG por sospecha de STC. Los examinadores que realizaron la ecografía desconocían los resultados del ENG. Posteriormente, se calcularon los puntos de corte mediante curvas ROC para cada una de las mediciones (AST-M y R-MA) y se analizó su validez diagnóstica. Resultados. Con un punto de corte de 9,15 mm2, la medición AST-M obtuvo una sensibilidad del 75,81%, una especificidad del 74,29%, una ratio de probabilidad positiva de 2,95 y una ratio de probabilidad negativa de 0,33. Para la medición R-MA y un punto de corte de 1,56, los valores de sensibilidad, especificidad y ratios de probabilidad positiva y negativa fueron 70,97%, 71,43%, 2,48 y 0,4, respectivamente. Conclusión. Tanto el AST-M como la R-MA parecen ser medidas útiles en el diagnóstico del STC tomando como prueba de referencia el ENG.es_ES
dc.description.abstractIntroduction: Ultrasonography has emerged as an alternative tool for diagnosing peripheral neuropathies, such as carpal tunnel syndrome (CTS). Yet, data are still lacking as regards the diagnostic validity of the different ultrasonography measurements for detecting CTS in clinical settings. Aims: To determine the diagnostic validity of ultrasound measurements of the cross-sectional area of the median nerve in the wrist (CSA-M) and of the ratio of the area of the median nerve between the wrist and the forearm (R-WF) in the diagnosis of CTS, using electroneuromyography (ENG) as the reference technique. Patients and methods: Ultrasound measurements were performed on 59 subjects (100 wrists) who were referred to have an ENG due to suspected CTS. The examiners that performed the ultrasonography scan did not know the results of the ENG. The cut-off points were later calculated by means of ROC curves for each of the measurements (CSA-M and R-WF) and their diagnostic validity was analysed. Results: With a cut-off point of 9.15 mm2, CSA-M measurement obtained a sensitivity of 75.81%, a specificity of 74.29%, a positive likelihood ratio of 2.95 and a negative likelihood ratio of 0.33. For the R-WF measurement and a cut-off point of 1.56, the values for sensitivity, specificity, and positive and negative likelihood ratios were 70.97%, 71.43%, 2.48 and 0.4, respectively. Conclusions: Both the CSA-M and R-WF appear to be useful measures in the diagnosis of CTS, taking the ENG as a reference test.en
dc.format.mimetypeapplication/pdfen
dc.identifier.citationBueno-Gracia, E., Haddad-Garay, M., Tricás-Moreno, J. M., Fanlo-Mazas, P., Estébanez-de-Miguel, E., Hidalgo-García, C., Ruiz-de-Escudero-Zapico, A. (2015) Validez diagnóstica de la ecografía en el síndrome del túnel carpiano. Revista de Neurología, 61(1), 1-6. https://doi.org/10.33588/rn.6101.2015062.
dc.identifier.doi10.33588/rn.6101.2015062
dc.identifier.issn0210-0010
dc.identifier.urihttps://academica-e.unavarra.es/handle/2454/53187
dc.language.isospa
dc.publisherViguera
dc.relation.ispartofRevista de Neurología 2015, 61(1), 1-6
dc.relation.publisherversionhttps://doi.org/10.33588/rn.6101.2015062
dc.rights© 2015 Revista de Neurología. Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.rights.urihttps://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subjectDiagnósticoes_ES
dc.subjectEcografíaes_ES
dc.subjectElectroneurogramaes_ES
dc.subjectNeuropatíaes_ES
dc.subjectSíndrome del túnel carpianoes_ES
dc.subjectValidez diagnósticaes_ES
dc.subjectCarpal tunnel syndromeen
dc.subjectDiagnosisen
dc.subjectDianostic validityen
dc.subjectElectroneuromyogramen
dc.subjectNeuropathyen
dc.subjectUltrasonographyen
dc.titleValidez diagnóstica de la ecografía en el síndrome del túnel carpianoes_ES
dc.title.alternativeDiagnostic validity of ultrasonography in carpal tunnel syndromeen
dc.typeinfo:eu-repo/semantics/article
dc.type.versioninfo:eu-repo/semantics/publishedVersion
dspace.entity.typePublication
relation.isAuthorOfPublication8fcb0fd8-423d-401d-9b1b-1235c35c8239
relation.isAuthorOfPublication.latestForDiscovery8fcb0fd8-423d-401d-9b1b-1235c35c8239

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Validez-diagnostica.pdf
Size:
210.99 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed to upon submission
Description: