Publication: Luminance calibration of a full sky HDR imaging system using sky scanner measurements
dc.contributor.author | García Ruiz, Ignacio | |
dc.contributor.author | Sáenz Gamasa, Carlos | |
dc.contributor.author | Hernández Salueña, Begoña | |
dc.contributor.author | García Santos, Rafael | |
dc.contributor.author | Torres Escribano, José Luis | |
dc.contributor.department | Zientziak | eu |
dc.contributor.department | Ingeniaritza | eu |
dc.contributor.department | Institute of Smart Cities - ISC | en |
dc.contributor.department | Institute for Advanced Materials and Mathematics - INAMAT2 | en |
dc.contributor.department | Ciencias | es_ES |
dc.contributor.department | Ingeniería | es_ES |
dc.date.accessioned | 2022-07-19T06:59:47Z | |
dc.date.available | 2022-07-19T06:59:47Z | |
dc.date.issued | 2022 | |
dc.date.updated | 2022-06-22T09:04:25Z | |
dc.description.abstract | A full sky High Dynamic Range imaging system, based on a Single-Lens Reflex camera with a fisheye lens, has been constructed and calibrated with a sky scanner luminance meter. The method considers the geometrical, spectral, timing and orientation issues between instruments. The calibration data sets, having nearly simultaneous measurements under stable sky conditions, were obtained from approximately one month of data using selection variables based in the experimental design. For luminance estimation we use the standard 𝐶𝐼𝐸𝑌 RGB combination and a Spectrally Matched Luminance (𝑆𝑀𝐿) predictor, matching the spectral response of the instruments. With 738 calibration points having luminances up to 23.6 kcd∕m2, covering 98.5% of the sky luminance range, 𝐶𝐼𝐸𝑌 is linearly correlated with sky scanner measurements with a coefficient of determination 𝑅2 = 0.9927 and a Root Mean Squared Error (𝑅𝑀𝑆𝐸) of 7.7%. 𝑆𝑀𝐿 gives better results, with 𝑅2 = 0.9973 and 𝑅𝑀𝑆𝐸 = 5.3%. With 253 calibration points with luminances up to 12.9 kcd∕m2, comprising 94.1% of the sky luminance range, both predictors clearly improve, with 𝑅2 = 0.9964 and 𝑅𝑀𝑆𝐸 = 4.1% in case of 𝐶𝐼𝐸𝑌 and 𝑅2 = 0.9982 and 𝑅𝑀𝑆𝐸 = 2.9% in case of 𝑆𝑀𝐿. | en |
dc.description.sponsorship | This work was performed in the framework of the IRILURREFLEX, Spain project (ENE2017-86974-R), financed by the Spanish State Research Agency (Agencia Estatal de Investigación, AEI) and the European Regional Development Fund (Fondo Europeo de Desarrollo Regional, FEDER). | en |
dc.format.extent | 23 p. | |
dc.format.mimetype | application/pdf | en |
dc.format.mimetype | application/zip | en |
dc.format.mimetype | video/mp4 | en |
dc.identifier.citation | García, I.; Sáenz, C.; Hernández, B.; García, R.; Torres, J. L. (2022). Luminance calibration of a full sky HDR imaging system using sky scanner measurements. Solar Energy. 239, 147-169 | en |
dc.identifier.doi | 10.1016/j.solener.2022.04.048 | |
dc.identifier.issn | 0038-092X | |
dc.identifier.uri | https://academica-e.unavarra.es/handle/2454/43345 | |
dc.language.iso | eng | en |
dc.publisher | Solar Energy Society | en |
dc.relation.ispartof | Solar Energy, 2022, 239,p. 147-169 | en |
dc.relation.projectID | info:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2013-2016/ENE2017-86974-R/ES/ | en |
dc.relation.publisherversion | https://doi.org/10.1016/j.solener.2022.04.048 | |
dc.rights | © 2022 The Author(s).This is an open access article under the CC BY-NC-ND license | en |
dc.rights.accessRights | Acceso abierto / Sarbide irekia | es |
dc.rights.accessRights | info:eu-repo/semantics/openAccess | en |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | |
dc.subject | HDR imaging | en |
dc.subject | Sky luminance | en |
dc.subject | Sky scanner | en |
dc.subject | Sky imager | en |
dc.subject | Luminance calibration | en |
dc.title | Luminance calibration of a full sky HDR imaging system using sky scanner measurements | en |
dc.type | info:eu-repo/semantics/article | |
dc.type.version | Versión publicada / Argitaratu den bertsioa | es |
dc.type.version | info:eu-repo/semantics/publishedVersion | en |
dspace.entity.type | Publication | |
relation.isAuthorOfPublication | dcdadcc0-60de-44b9-8af5-c2c523c90d95 | |
relation.isAuthorOfPublication | 3f992369-f699-4f70-a529-0d02d35c0988 | |
relation.isAuthorOfPublication | 5b3647dd-4c80-477d-9591-075c1148b862 | |
relation.isAuthorOfPublication | a036209d-4575-411d-ad6e-9e75ba218b26 | |
relation.isAuthorOfPublication | 0c2c3245-d515-48d1-8f44-1cdd61fb4bcc | |
relation.isAuthorOfPublication.latestForDiscovery | dcdadcc0-60de-44b9-8af5-c2c523c90d95 |
Files
Original bundle
1 - 4 of 4
Loading...
- Name:
- Garcia_LuminanceCalibration_1655708864264_41474.pdf
- Size:
- 4.63 MB
- Format:
- Adobe Portable Document Format
No Thumbnail Available
- Name:
- Garcia_LuminanceCalibration_MatComplA.zip
- Size:
- 4.19 MB
- Format:
- ZIP
No Thumbnail Available
- Name:
- Garcia_Luminance calibration_MatCompl_Video1.mp4
- Size:
- 2.13 MB
- Format:
- Unknown data format
No Thumbnail Available
- Name:
- Garcia_Luminance calibration_MatCompl_Video2.mp4
- Size:
- 2.12 MB
- Format:
- Unknown data format
License bundle
1 - 1 of 1
No Thumbnail Available
- Name:
- license.txt
- Size:
- 1.78 KB
- Format:
- Item-specific license agreed to upon submission
- Description: