Sistema de detección de obstáculos en silla de ruedas para pacientes con heminegligencia

dc.contributor.advisorTFEMartínez Ramírez, Alicia
dc.contributor.advisorTFERemírez Moreno, Berta
dc.contributor.affiliationEscuela Técnica Superior de Ingeniería Industrial, Informática y de Telecomunicaciónes_ES
dc.contributor.affiliationIndustria, Informatika eta Telekomunikazio Ingeniaritzako Goi Mailako Eskola Teknikoaeu
dc.contributor.authorCadena Yánez, Mishell
dc.coverage.spatialeast=-1.6092724; north=42.7860423; name=Navarra, España
dc.date.accessioned2021-04-16T14:38:40Z
dc.date.issued2021
dc.date.updated2021-04-13T11:11:47Z
dc.description.abstractLa heminegligencia es el producto de lesiones cerebrovasculares en la zona parietal posterior-inferior y la corteza premotora. Este tipo de patología está caracterizada por incapacidad para detectar, orientarse o responder a estímulos novedosos o significativos procedentes de regiones espaciales contralaterales. En este TFM se ha desarrollado un sistema modular para la detección de obstáculos en silla de ruedas para pacientes con heminegligencia mediante sensores radar e infrarrojo. En este documento se muestra la definición de requerimientos establecidos por el personal sanitario que trabaja con pacientes con heminegligencia espacial. Se detalla la elección y justificación para cumplir con dichos requerimientos teniendo en cuenta los escenarios con los que se puede encontrar un paciente en estas condiciones, así como los resultados de validación del sistema. El sistema es capaz de detectar móviles que se acercan al el a una velocidad máxima de 2.23 m/s cuando la silla transita a 1.67 m/s produciendo una alarma de 24 PWM, valor que se ha comprobado experimentalmente que sirve para alerta a quien usa la silla sin producirle molestias ni alteraciones. El sistema también alerta sobre peligros por caída en aceras o escaleras, en este caso el sistema detectó en media 1.225 m antes y para acera detectó 0.809 m antes de que la acera de circulación de peatones termine. El sistema tiene una batería intercambiable y recargable de 1200 mAh lo que le brinda una autonomía de 1.11 hes_ES
dc.description.abstractOne of the consequences of cerebrovascular damage in the posteriorinferior parietal zone and the premotor cortex is hemineglect. This type of pathology is characterized by the inability to detect, orient or respond to novel or significant stimuli from contralateral spatial regions. In this project, a modular system for the detection of obstacles in a wheelchair for patients with hemineglect has been developed using radar and infrared sensors. This document shows the definition of requirements established by healthcare personnel who works with patients with hemineglect. The choice and justification to comply with these requirements is detailed, taking into account the scenarios with which a patient may be found in these conditions as well and validation results. The system is capable of detecting mobiles at a maximum speed of 2.23 m/s when the chair travels at 1.67 m / s producing a 24 PWM alarm, this value has been experimentally tested to be used for alert the pacient who use the chair without causing discomfort or alterations. The system also warns about dangers due to falls on sidewalks or stairs, in this case the system detected an average of 1.225 m before and for the sidewalk it detected 0.809 m before the sidewalk for pedestrian circulation ends. The system has an interchangeable and rechargeable 1200 mAh battery which gives it a range of 1.11 h.en
dc.description.degreeMáster Universitario en Ingeniería Biomédica por la Universidad Pública de Navarraes_ES
dc.description.degreeIngeniaritza Biomedikoko Unibertsitate Masterra Nafarroako Unibertsitate Publikoaneu
dc.embargo.inicio2021-04-16
dc.embargo.lift2026-04-01
dc.embargo.terms2026-04-01
dc.format.mimetypeapplication/pdfen
dc.identifier.urihttps://academica-e.unavarra.es/handle/2454/39570
dc.language.isospaen
dc.rights.accessRightsinfo:eu-repo/semantics/embargoedAccess
dc.subjectHeminegligenciaes_ES
dc.subjectDetección objetoses_ES
dc.subjectSensor radares_ES
dc.subjectSensor infrarrojoes_ES
dc.subjectTiempo de reacciónes_ES
dc.subjectHemineglecten
dc.subjectObject detectionen
dc.subjectRadar sensoren
dc.subjectInfrared sensoren
dc.subjectReaction timeen
dc.titleSistema de detección de obstáculos en silla de ruedas para pacientes con heminegligenciaes_ES
dc.typeinfo:eu-repo/semantics/masterThesis
dspace.entity.typePublication
relation.isAdvisorTFEOfPublication2c45ccc2-cdb5-497e-ac89-78ff8eba5287
relation.isAdvisorTFEOfPublication2e19d8e9-22b1-4a43-a39f-410c174c8260
relation.isAdvisorTFEOfPublication.latestForDiscovery2c45ccc2-cdb5-497e-ac89-78ff8eba5287

Files

Original bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
TFM_CADENA_PM.pdf
Size:
1.72 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.78 KB
Format:
Item-specific license agreed to upon submission
Description: