Publication:
Accuracy of smartwatch electrocardiographic recording in the acute coronary syndrome setting: rationale and design of the ACS WATCH II Study

Date

2024

Authors

Buelga Suárez, Mauro
Pascual Izco, Marina
García Montalvo, Jesús

Director

Publisher

MDPI
Acceso abierto / Sarbide irekia
Artículo / Artikulua
Versión publicada / Argitaratu den bertsioa

Project identifier

Impacto
OpenAlexGoogle Scholar
cited by count

Abstract

Background: Acute Coronary Syndrome (ACS), with or without ST-segment elevation, is a major contributor to global mortality and morbidity. Swift diagnosis and treatment are vital for mitigating cardiac damage and improving long-term outcomes. The 12-lead electrocardiogram (ECG) currently serves as the gold standard for diagnosis in ACS with ST-segment elevation and may support the diagnosis in ACS without ST-segment elevation. However, the growing prevalence of smartwatches enables the acquisition of electrocardiographic data without traditional ECG equipment. While smaller studies support smartwatch ECG use, larger-scale validation within ACS remains lacking. The ACS WATCH II study aims to validate smartwatch ECG recordings for ACS. Methods: The primary objective is to validate smartwatch-obtained electrocardiographic data in patients presenting with ACS. Two cohorts of 120 patients each, presenting ACS with and without ST-segment elevation, will be assessed. Smartwatches will capture recordings of leads I, III, and V2 alongside standard ECGs. These leads, chosen due to a 97% ACS diagnosis sensitivity in previous studies, will undergo blind evaluation by two experienced external assessors against conventional ECG. Additionally, a control sample of 60 healthy individuals will be included. Conclusions: ACS WATCH II pioneers large-scale prospective validation of smartwatch ECG recordings in ACS patients. Additionally, it indirectly validates a swift diagnostic approach using three leads (I, III, and V2). This could expedite time-critical ACS diagnoses and simplify access through smartwatch-based diagnosis.

Description

Keywords

Acute coronary syndrome, Acute myocardial infarction, ECG tracing, Ischemic heart disease, NSTEMI, Smartwatch, STEMI

Department

Ciencias de la Salud / Osasun Zientziak

Faculty/School

Degree

Doctorate program

item.page.cita

Buelga Suárez, M., Pascual Izco, M., García Montalvo, J., Alonso Salinas, G. L. (2024) Accuracy of smartwatch electrocardiographic recording in the acute coronary syndrome setting: Rationale and design of the ACS WATCH II Study. Journal of Clinical Medicine, 13(2), 1-8. https://doi.org/10.3390/jcm13020389.

item.page.rights

© 2024 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license.

Licencia

Los documentos de Academica-e están protegidos por derechos de autor con todos los derechos reservados, a no ser que se indique lo contrario.