Improving enantiomeric resolutions by avoiding peak distortion effects in on-line coupled liquid chromatography to gas chromatography

dc.contributor.authorMartínez, Rosa M.
dc.contributor.authorBarba González-Albo, Carmen
dc.contributor.authorRobredo, Sergio
dc.contributor.authorHerraiz, Marta
dc.contributor.departmentAgronomía, Biotecnología y Alimentaciónes_ES
dc.contributor.departmentAgronomia, Bioteknologia eta Elikaduraeu
dc.date.accessioned2020-03-23T09:23:52Z
dc.date.available2020-07-22T23:00:13Z
dc.date.issued2019
dc.description.abstractIn this work, we study the effect of different variables affecting elution profile distortion on the enantiomeric resolution eventually achievable when working with on-line coupled liquid chromatography to gas chromatography (LC-GC). Specifically, the proposed configuration combines achiral reversed-phase liquid chromatography (RPLC) and chiral gas chromatography (enantio-GC), with heptakis-(2,3,6-tri-O-methyl)-beta-cyclodextrin as enantioselective stationary phase to analyse target fractions transferred (from LC to GC) via the through oven transfer adsorption desorption (TOTAD) interface. The high degree of orthogonality resulting from the combination of two chromatographic columns having very different separation mechanisms (and also requiring mobile phases in distinct physical states), as well as integration of the sample preparation step in the first dimension of the system, significantly contributed to exploit the performance of the proposed two-dimensional approach. Occasional adverse effects, which may result in severe peak distortions during LC-GC analysis and could be explained by flow instabilities due to viscous fingering, are circumvented by using the outstanding capacity of the TOTAD interface for achieving effective elimination of the eluent arriving from the LC preseparation.en
dc.description.sponsorshipSpanish Ministry of Economy and Competitiveness, Grant/Award Numbers: IPT‐010000‐2010‐017 and DEP2012‐35225en
dc.embargo.lift2020-07-22
dc.embargo.terms2020-07-22
dc.format.extent9 p.
dc.format.mimetypeapplication/pdfen
dc.identifier.doi10.1002/chir.23121
dc.identifier.issn0899-0042
dc.identifier.urihttps://academica-e.unavarra.es/handle/2454/36556
dc.language.isoengen
dc.publisherWileyen
dc.relation.ispartofChirality, 2019; 31:879-891en
dc.relation.projectIDinfo:eu-repo/grantAgreement/ES/6PN/DEP2012‐35225/
dc.relation.publisherversionhttps://doi.org/10.1002/chir.23121
dc.rights© 2019 Wiley Periodicals, Inc.en
dc.rights.accessRightsinfo:eu-repo/semantics/openAccess
dc.subjectChiral analysisen
dc.subjectEnantiodifferentiationen
dc.subjectEnantio‐multidimensional chromatographyen
dc.subjectOn‐line coupling LC‐GCen
dc.subjectPeak shape distortionen
dc.subjectViscous fingeringen
dc.titleImproving enantiomeric resolutions by avoiding peak distortion effects in on-line coupled liquid chromatography to gas chromatographyen
dc.typeinfo:eu-repo/semantics/article
dc.type.versioninfo:eu-repo/semantics/acceptedVersion
dspace.entity.typePublication
relation.isAuthorOfPublication5c628f43-9482-4e1b-9413-6adb8a20c29d
relation.isAuthorOfPublication.latestForDiscovery5c628f43-9482-4e1b-9413-6adb8a20c29d

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
2019100322_Martinez_ImprovingEnantiomeric.pdf
Size:
424.56 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed to upon submission
Description: